Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UNIPROT:Q9NRP7 (fused)
58,367 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

By techniques of recombination in vitro, we have constructed a plasmid bearing the repressor gene (cI) of bacteriophage lambda fused to the promoter of the lac operon. Strains carrying this plasmid overproduce lambda repressor. This functional cI gene was reconstituted by joining DNA fragments bearing different parts of that gene. Flush end fusion techniques, involving no sequence overlap, were necessary for the construction; in certain cases, the abutting of the DNA molecules bearing ends generated by different restriction endonucleases creates a sequence at the junction which is recognized by one of the restriction endonucleases.
...
PMID:Construction of plasmids carrying the cI gene of bacteriophage lambda. 106 7

High-resolution capillary electrophoretic separation of proteins and peptides was achieved by coating the inner wall of 75 microm ID fused-silica capillaries with 40-140 nm polystyrene particles which have been derivatized with alpha-omega-diamines such as ethylenediamine or 1,10-diaminodecane. A stable and irreversibly adsorbed coating was obtained upon deprotonation of the capillary surface with aqueous sodium hydroxide and subsequent flushing with a suspension of the positively charged particles. At pH 3.1, the detrimental adsorption of proteins to the capillary inner wall was suppressed efficiently because of electrostatic repulsion of the positively charged proteins from the positively charged coating which enabled protein separations with maximum efficiencies of 400000 plates per meter. A substantial improvement of separation efficiency in particle-coated capillaries was observed after in-column derivatization of amino functionalities with 2,3-epoxy-l-propanol, resulting in a more hydrophilic coating. Five basic and four acidic proteins could be separated in less than 7 min with efficiencies up to 1900000 theoretical plates per meter. Finally, coated capillaries were applied to the high-resolution analysis of protein glycoforms and bioactive peptides.
...
PMID:Capillary electrophoresis of peptides and proteins in fused-silica capillaries coated with derivatized polystyrene nanoparticles. 954 89

A new type of monolithic stationary phase was prepared within the confines of fused-silica tubing by in situ polymerization of divinylbenzene or ethylene dimethacrylate either with styrene or butyl methacrylate. The porosity of the monolith was dictated by silica beads packed in the capillary prior to flushing the column with the monomeric solution. Subsequent washing of the polymeric rod with sodium hydroxide rendered a porous monolith that was used for both micro-LC and capillary electrochromatography. The novelty of the approach presented herein lies in preparing the polymer within the confines of a fused-silica capillary. The challenges posed in this new context and their resolution are presented in detail. In addition, this study proposes that in addition to tailoring the pore size, the silica beads, through their surface chemistry, can influence the surface characteristics of the finished polymer monolith. For example, the data suggests that octadecyl modified silica particles interacted with hydrophobic moieties of monomers before initiation of polymerization, thus dictating their orientation in the resulting polymer.
...
PMID:Novel monolithic columns with templated porosity. 1152 68

A solid-phase extraction method based on an ion-exchange retention mechanism has been used for in-line preconcentration of inorganic anions prior to their separation by capillary electrophoresis (CE). A single capillary containing a preconcentration and a separation zone has been used in a commercial CE instrument without instrumental modification. Analyte anions were retained on a preconcentration zone comprising an adsorbed layer of cationic latex particles, while separation was achieved in a separation zone comprising fused silica modified by adsorption of a cationic polymer. Elution of the adsorbed analytes was achieved using an eluotropic gradient formed by a transient isotachophoretic boundary between a fluoride electrolyte and a naphthalenedisulfonate electrolyte. Optimization of the electrolyte concentrations, sample injection times, and back-flushing times allowed the successful separation of sub-ppb levels of inorganic anions using a 100-min injection at 2 bar pressure, introducing over 40 capillary volumes of sample. A method based on a 10-min injection allowed a 100-fold increase in sensitivity over conventional hydrodynamic injection for Br-, I-, NO3-, CrO4(2-), and MoO4(2-) with a total analysis time of 25 min. Detection limits were dependent on the injection time but were in the range 2.2-11.6 ppb for a 10-min injection time. This approach was used to determine NO3- in Antarctic ice cores where the analysis could be performed using a sample volume 100 times less than that used for ion chromatography.
...
PMID:On-column ion-exchange preconcentration of inorganic anions in open tubular capillary electrochromatography with elution using transient-isotachophoretic gradients. 3. Implementation and method development. 1203 14

A preliminary study of a modified microconcentric nebulizer (CEI-100, CETAC) as the sample introduction device of capillary electrophoresis inductively coupled plasma mass spectrometry (CE-ICP-MS) for the determination of monophosphate nucleotides is described. The monophosphate nucleotides studied include adenosine 5'-monophosphate (AMP), guanosine 5'-monophosphate (GMP), uridine 5'-monophosphate (UMP) and inosine 5'-monophosphate (IMP). The species studied were well separated using a 70 cm length x 75 microm id fused silica capillary while the applied voltage was set at -22 kV and a 20 mmol l(-1) ammonium citrate/citric acid buffer (pH 4.0) containing 0.1% m/v cationic polymer (hexadimethrine bromide, Polybrene) was used as the electrophoretic buffer. The electroosmotic flow was reversed by flushing the fused silica capillary with 0.2% m/v Polybrene to accelerate separation. The detection limit of various species studied was in the range of 0.036-0.054 microg P ml(-1), which corresponded to the absolute detection limit of 1.1-1.6 pg P based on the injection volume of 30 nl. We determined the concentrations of nucleotides in two IG-enriched monosodium glutamates purchased from the local market. The recovery was in the range of 100-112% for various species, and the concentrations of IMP and GMP in these samples were in the range of 0.15-0.18% m/m.
...
PMID:Determination of monophosphate nucleotides by capillary electrophoresis inductively coupled plasma mass spectrometry. 1243 Jun 3

The copolymer of acrylonitrile, methyl acrylate, hydroxy ethyl acrylate (ZB-004), the copolymer of acrylonitrile, methyl acrylate, hydroxy ethyl acrylate, acrylamide (ZB-014) and the copolymer of acrylonitrile, hydroxy ethyl acrylate (ZB-016) were coated on the inner surface of fused-silica capillaries by just filling the capillary with solutions containing these copolymers followed by flushing the capillary with nitrogen. The physically adsorbed layer can reduce both protein adsorption and electroosmotic flow in the pH range of 3-5. Electroosmotic flow decreased by raising the concentrations of the copolymers. Separation performance of ZB-004 layer is better than those of other two layers due to its low hydrophilicity, but with higher pH values, appreciable peak deformation and increase in electroosmosis were observed. The intra day and inter day migration reproducibility were investigated in terms of relative standard deviation (RSD) with four basic proteins at pH 4.0. The RSDs of the intra day migration times were less than 2%. The RSDs of the inter day migration times were less than 4%. At pH 5.0, the RSDs of the migration times in two ZB-004-coated capillaries made on two different days were less than 1%. Separation efficiencies of four basic proteins in a ZB-004-coated capillary which stored in a buffer (pH 4.0) for fifteen days after being used for 14 days decreased 15%. These coatings were stable and exhibited reproducible separations from intra day, inter day and inter column under acidic conditions.
...
PMID:[The novel copolymer coated capillary columns of electrophoresis and their applications to separation of proteins]. 1254 33

A new polycationic coating for use in capillary electrophoresis has been developed that enables chemical modification of fused-silica capillary surfaces for analysis of compounds like basic proteins. The cationic polyamine, containing short aliphatic blocks of combined 2 and 3-carbon length, was physically adsorbed onto the negatively charged fused-silica surface through ionic interaction by flushing the capillary with a polyamine solution, followed by a self-stabilization step. The polyamine coated capillaries generated an anodal electroosmotic flow that was independent of pH in the investigated range of pH 4-8. The capillary performance was demonstrated by fast separations of basic proteins with peak efficiencies in the range of 265,000-584,000 plates.
...
PMID:Novel polyamine coating providing non-covalent deactivation and reversed electroosmotic flow of fused-silica capillaries for capillary electrophoresis. 1289 12

Automated sampling and fluorogenic derivatization of islet proteins (insulin, proinsulin, c-peptide) are separated and analyzed by a novel lab-on-valve capillary electrophoresis (LOV-CE) system. This fully integrated device is based on a micro sequential injection instrument that uses a lab-on-valve manifold to integrate capillary electrophoresis. The lab-on-valve manifold is used to perform all microfluidic tasks such as sampling, fluorogenic labeling, and CE capillary rejuvenation providing a very reliable system for reproducible CE separations. Fluorescence detection was coupled to an epiluminescence fluorescence microscope using a customized capillary positioning plate. This customized plate incorporated two fused-silica fiber optic probes that allow for simultaneous absorbance and fluorescence detection, extending the utility of this device. Derivatization conditions with respect to the sequence of addition, timing, injection position, and volumes were optimized through iterative series of experiments that are executed automatically by software control. Reproducibility in fluorogenic labeling was tested with repetitive injections of 3.45 mM insulin, yielding 1.3% RSD for peak area, 0.5% RSD for electromigration time, and 2.8% RSD for peak height. Fluorescence detection demonstrated a linear dynamic range of 3.43 to 6.87 microM for insulin (r2 = 0.99999), 0.39 to 1.96 pM for proinsulin (r2 = 0.99195) and 260 to 781 nM for c-peptide (r2 = 0.99983). By including hydrodynamic flushing immediately after the detection of the last analyte, the sampling frequency for islet protein analysis was increased. Finally, an in vitro insulin assay using rat pancreatic islet excretions was tested using this lab-on-valve capillary electrophoresis system.
...
PMID:Micro sequential injection: automated insulin derivatization and separation using a lab-on-valve capillary electrophoresis system. 1452 18

The usefulness of a noncovalent capillary coating consisting of two layers of oppositely charged polymers for the separation of peptides with capillary electrophoresis (CE) was studied. Capillaries were coated simply by subsequently flushing with solutions of 1% m/v Polybrene and 1% v/v poly(vinylsulfonate) (PVS) forming a bilayer, which showed to produce a strong and highly reproducible electroosmotic flow (EOF) at low pH. Using this coating in combination with a background electrolyte (BGE) containing sodium phosphate (pH 2.5) and 0.01% v/v PVS, initially broadened and overlapping peaks were obtained for some test peptides. By omitting the PVS from the BGE, the peak width and shape of the peptides improved resulting in baseline separation. A systematic study of the influence of the BGE composition showed that considerable further enhancement of the separation efficiency was achieved by increasing the ionic strength of the BGE. Using a BGE of 200 mM tris(hydroxymethyl)aminomethane (Tris)-phosphate (pH 2.5) plate numbers for the peptides were in the 300 000-600 000 range and the relative standard deviation of the peptide migration times was less then 0.3% (n = 5). The use of Tris-phosphate instead of sodium phosphate allowed the current to stay within acceptable limits when 30 kV was used as separation voltage. Overall, the bilayer coating showed a remarkable EOF repeatability, as well as long-term stability. Compared to bare fused-silica capillaries the intraday and interday repeatability of migration times was very favorable and coated capillaries could be used for over a month performing analyses with low and high ionic strength BGEs without any performance deterioration. The usefulness of the bilayer-coated capillaries for the analysis of positively charged peptides was demonstrated by the fast and efficient separation of various closely related enkephalins and the baseline separation of an isomeric peptide/peptoid couple exhibiting efficiencies of over 550 000 plates.
...
PMID:Efficient and reproducible analysis of peptides by capillary electrophoresis using noncovalently bilayer-coated capillaries. 1500 41

A novel positively charged polymer of quaternary ammonium substituted agarose (Q-agarose) has been synthesized and explored for use as a coating in capillary electrophoresis. The fast and simple coating procedure is based on a multi-site electrostatic interaction between the polycationic agarose polymer and the negatively charged fused-silica surface. By simply flushing fused-silica capillaries with hot polymer solution a positively charged, hydrophilic deactivation layer is achieved. The polymer surface provides an intermediate electroosmotic flow of reversed direction, over a range of pH 2-11, compared to unmodified fused-silica. The coating procedure was highly reproducible with an RSD of 4%, evaluated as the electroosmotic flow mobility for 30 capillaries prepared at 10 different occasions. The application of Q-agarose coated capillaries in separation science was investigated using a set of basic drugs and model proteins and peptides. Due to the intermediate electroosmotic flow generated, the resolution of basic drugs could be increased, compared to using bare fused-silica capillaries. Moreover, the coating enabled separation of proteins and peptides with efficiencies up to 300.000 plates m(-1).
...
PMID:Quaternary ammonium substituted agarose as surface coating for capillary electrophoresis. 1511 32


1 2 3 Next >>