Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UNIPROT:Q99581 (
FEV
)
3,296
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
In support of Health Effects Research Studies, pulmonary function tests are periodically administered to a large number of children. The ventilatory performance of these children is being evaluated by measuring the 0.75-sec forced expiratory volume (
FEV
(0.75)) with a waterless mechanical volume spirometer used in conjunction with an electronic timing unit. During a 1-yr testing period, operation with the volume spirometer and the
EPA
designed electronic timing unit proved to be highly successful. The volume spirometer was found to be more advantageous in conducting tests at remote field stations than the water spirometer and other electronic instruments which measure flow rate with a transducer element. The volume spirometer is lightweight, easy to operate, and has the capability of easy and accurate field calibration when used in conjunction with the electronic timing unit. Presently the volume spirometer and
EPA
designed electronic timing package are employed in all Community Health and Surveillance System (CHESS) pulmonary function testing studies.
...
PMID:Application and evaluation of portable field instruments for measuring forced expiratory volume of children and adults in environmental health surveys. 447 Sep 17
Chrysotile asbestos fiber, imported from Russia, is used mainly for manufacturing purposes in Iran and related risks in the form of asbestosis and cancer were studied. Occupational exposure of all male workers (61 persons) to asbestos in a brake shoe factory was monitored. Cumulative exposures were determined through multiplication of typical exposure and work history. Risk assessment of exposed workers was estimated by risk criteria recommended by the American Environmental Protection Agency. Measurement of lung function parameters such as forced expiratory volume in one second (
FEV
(1)), forced volume capacity (FVC) and
FEV
(1)/FVC of exposed workers were obtained. Unadjusted correlation and adjusted correlation analysis for support of the association between cumulative exposure (fiber/ml-yr) and lung function parameters were used. Exposure of majority of exposed group was far greater than the occupational exposure limits (0.1 fiber/ml) in the range of 0.06-8.06 fiber/ml. Cumulative exposures in the range of 0.02 to 110.77 fiber/ml-yr were obtained. According to the risk criteria stated by ATSDR, risk assessment of workers in term of fibrotic changes was predicted for at least 24.6 percent of the exposed subjects. Again, according to the lung cancer risk criteria stated by
EPA
, 59 percent of workers will have excess risk. Negative correlation between lung function parameters (
FEV
(1),
FEV
(1)/FVC) and cumulative exposures adjusted for age and BMI were significant (p<0.05).
...
PMID:Risk assessment of lung cancer and asbestosis in workers exposed to asbestos fibers in brake shoe factory in Iran. 2016 Apr 6