Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UNIPROT:Q86TM3 (cage)
29,987 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Left coronary occlusion in the rat was performed by cornary artery cauterization. A small amount of myocardial damage at the site of occlusion was noted, and myocardial infarction occurred in the distal distribution of the obstructed coronary. The effects of cage size and level of physical activity on estimated infarct size (as measured by creatine kinase depletion) 48 h after occlusion were determined. Isolation in small cages and moderate treadmill exercise resulted in an approximate doubling of the amount of infarction when compared to grouping of rats in large cages. Mild exercise did not increase infarct size. Total urinary catecholamines in normal rats placed in small cages for 48 h were elevated when compared to unconfined rats in larger cages. Cornary artery occlusion by cauterization is an easily performed technique. Cage size and level of activity (and their effects on sympathoadrenal function) are important independent determinations of infarct extent after coronary occlusion in the rat.
...
PMID:Cage size and exercise affects infarct size in rat after coronary artery cauterization. 46 97

A newly designed flow support catheter with a supporting wire mesh cage which can be expanded into a tubular configuration and then readily reduced was evaluated in mongrel dogs. Regional myocardial blood flow (RMBF) was measured using the radioactive microsphere technique in the area of both balloon-denuded instrumented and control non-instrumented coronary arteries following placement of either a fixed-wire or a higher profile rapid exchange flow support catheter. At 5, 20, and 180 min following delivery and expansion of either device, RMBF was not significantly different in left ventricular subepicardium and subendocardium perfused by the instrumented vs. the control coronary arteries. Angiography demonstrated widely patent instrumented arteries in 15/18 dogs; in no dog was side branch occlusion observed. Significant cage thrombus deposition was seen angiographically in 3 animals causing temporary total coronary occlusion in 1. Following reduction and removal of the flow support catheter, vessel patency was present in all dogs. The flow support catheter is an effective endovascular stenting device capable of providing structural arterial support, while simultaneously maintaining distal coronary blood flow. It is envisioned that the primary application of this catheter will be to enable primary salvage of vessels acutely injured during coronary angioplasty, by "tacking up" intimal flaps for an extended period. It may also provide a bridge to emergency surgical revascularization.
...
PMID:Flow support catheter for prolonged maintenance of coronary blood flow. 175 71