Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UNIPROT:Q3SYG4 (C18)
23,707 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

R,S-sotalol, a ss-blocker drug with class III antiarrhythmic properties, is prescribed to patients with ventricular, atrial and supraventricular arrhythmias. A simple and sensitive method based on HPLC-fluorescence is described for the quantification of R,S-sotalol racemate in 500 microl of plasma. R,S-sotalol and its internal standard (atenolol) were eluted after 5.9 and 8.5 min, respectively, from a 4-micron C18 reverse-phase column using a mobile phase consisting of 80 mM KH2PO4, pH 4.6, and acetonitrile (95:5, v/v) at a flow rate of 0.5 ml/min with detection at lambdaex = 235 nm and lambdaem = 310 nm, respectively. This method, validated on the basis of R,S-sotalol measurements in spiked blank plasma, presented 20 ng/ml sensitivity, 20-10,000 ng/ml linearity, and 2.9 and 4.8% intra- and interassay precision, respectively. Plasma sotalol concentrations were determined by applying this method to investigate five high-risk patients with atrial fibrillation admitted to the Emergency Service of the Medical School Hospital, who received sotalol, 160 mg po, as loading dose. Blood samples were collected from a peripheral vein at zero, 0.5, 1.0, 1.5, 2.0, 3.0, 4. 0, 6.0, 8.0, 12.0 and 24.0 h after drug administration. A two-compartment open model was applied. Data obtained, expressed as mean, were: C MAX = 1230 ng/ml, T MAX = 1.8 h, AUC T = 10645 ng h-1 ml-1, Kab = 1.23 h-1, alpha = 0.95 h-1, ss = 0.09 h-1, t((1/2))ss = 7.8 h, ClT/F = 3.94 ml min-1 kg-1, and Vd/F = 2.53 l/kg. A good systemic availability and a fast absorption were obtained. Drug distribution was reduced to the same extent in terms of total body clearance when patients and healthy volunteers were compared, and consequently elimination half-life remained unchanged. Thus, the method described in the present study is useful for therapeutic drug monitoring purposes, pharmacokinetic investigation and pharmacokinetic-pharmacodynamic sotalol studies in patients with tachyarrhythmias.
...
PMID:A simple HPLC-fluorescence method for the measurement of R,S-sotalol in the plasma of patients with life-threatening cardiac arrhythmias. 1065 59

In this work, several commercial sorbents (Zorbax C18, Bond Elut C18, Isolute ENV+, Oasis HLB, Oasis MAX, SDB-RPS, and MPC-SD) were compared for the solid-phase extraction of the series of quinolones regulated by the European Community in chicken tissues in order to establish a method for the determination of this series of quinolones by capillary electrophoresis and diode array detection. Sorbents were chosen in order to achieve maximum recoveries and optimal clean-up efficiency. Better results were obtained using SDB-RPS and Oasis MAX which would provide suitable limits of detection, below of the maximum residue limits (MRLs) regulated.
...
PMID:Effective sorbents for solid-phase extraction in the analysis of quinolones in animal tissues by capillary electrophoresis. 1473 May 70

S-phenylmercapturic acid is widely accepted as a specific biomarker for the evaluation of benzene exposure. Here, we describe a fast, specific and sensitive high-performance liquid achromatography coupled with tandem mass spectrometry (LC-MS/MS) method that has been developed and validated for the determination of S-phenylmercapturic acid in human urine. Isotope-labeled S-phenylmercapturic acid-d5 was used as internal standard to improve the method ruggedness. The fully automated solid-phase extraction method on a 96-well Oasis MAX (mix-mode anion exchange) plate was employed to clean up the urine samples before analysis. The rapid LC-MS/MS analysis of extracted samples was achieved on a Genesis C18 column with a run time of only 3 min. Negative electrospray ionization with multiple reaction monitoring (ESI-MRM) mode was used to detect S-phenylmercapturic acid (m/z 238 --> 109) and S-phenylmercapturic acid -d5 (m/z 243 --> 114). The method fulfils all the standard requirements of method validation. The calibration curve was linear within the concentration range 0.400-200 ng/mL. The method performed accurately and precisely in validation with <7.5% relative error and <6.5% relative standard deviation of quality control samples. The method efficacy was also verified by the analysis of urine samples from 12 smokers and 12 non-smokers. With the fully automated sample cleanup procedure and the fast LC-MS/MS analysis, a sample analysis throughput of 384 samples per day could be achieved.
...
PMID:Determination of S-phenylmercapturic acid in human urine using an automated sample extraction and fast liquid chromatography-tandem mass spectrometric method. 1677 71

The effect of piecewise direct standardization (PDS) and baseline correction approaches was evaluated in the performance of multivariate curve resolution (MCR-ALS) algorithm for the resolution of three-way data sets from liquid chromatography with diode-array detection (LC-DAD). First, eight tetracyclines (tetracycline, oxytetracycline, chlorotetracycline, demeclocycline, methacycline, doxycycline, meclocycline and minocycline) were isolated from 250 mL effluent wastewater samples by solid-phase extraction (SPE) with Oasis MAX 500 mg/6 mL cartridges and then separated on an Aquasil C18 150 mm x 4.6mm (5 microm particle size) column by LC and detected by DAD. Previous experiments, carried out with Milli-Q water samples, showed a considerable loss of the most polar analytes (minocycline, oxitetracycline and tetracycline) due to breakthrough. PDS was applied to overcome this important drawback. Conversion of chromatograms obtained from standards prepared in solvent was performed obtaining a high correlation with those corresponding to the real situation (r2 = 0.98). Although the enrichment and clean-up steps were carefully optimized, the sample matrix caused a large baseline drift, and also additive interferences were present at the retention times of the analytes. These problems were solved with the baseline correction method proposed by Eilers. MCR-ALS was applied to the corrected and uncorrected three-way data sets to obtain spectral and chromatographic profiles of each tetracycline, as well as those corresponding to the co-eluting interferences. The complexity of the calibration model built from uncorrected data sets was higher, as expected, and the quality of the spectral and chromatographic profiles was worse.
...
PMID:Solving matrix-effects exploiting the second order advantage in the resolution and determination of eight tetracycline antibiotics in effluent wastewater by modelling liquid chromatography data with multivariate curve resolution-alternating least squares and unfolded-partial least squares followed by residual bilinearization algorithms I. Effect of signal pre-treatment. 1809 3

A new, single-step extraction and purification method based on matrix solid-phase dispersion (MSPD) was developed to determine 17 polycyclic aromatic hydrocarbons (PAHs) in sewage sludge samples. The MSPD method consists of sample homogenisation, exhaustive extraction and clean-up by a single process. The different operational parameters of the method, such as the type of dispersant, type and amount of additives, clean-up co-sorbent and extractive solvent were evaluated. Reversed-phase (C18) and polymeric (Oasis HLB and Oasis MAX) materials, as well as normal phase sorbents (Florisil, silica, neutral alumina) and an inert support (sand) were tested to assess the sorbents effect on the yield and selectivity of the MSPD process. Analysis of extracts was performed by high performance liquid chromatography (HPLC) coupled with fluorescence detection. Quantification limits obtained for all of these considered compounds (between 0.0001 and 0.005mugg(-1) dry mass) were well below of the limits recommended in the EU. The extraction yields for the different compounds obtained by MSPD ranged from 76.3% to 103.6%. On the other hand, the extraction efficiency of the optimised method is compared with that achieved by microwave-assisted extraction and the method was applied to the analysis of real sewage sludge samples. A certified reference material (sewage sludge (BCR 088)) and a reference material (sewage sludge (RTC-CNS312-04)) were used to validate the proposed method.
...
PMID:Development of a matrix solid-phase dispersion method for the determination of polycyclic aromatic hydrocarbons in sewage sludge samples. 1879 Jan 16

A fast and sensitive high-performance liquid chromatographic method has been developed for the determination in human plasma of MHPG (3-methoxy-4-hydroxyphenylethylenglycol) and VMA (vanillyl mandelic acid), the main metabolites of epinephrine and norepinephrine. Analyses were carried out at 325 nm while exciting at 285 nm on a reversed-phase column (Atlantis C18, 150 mm x 4.6 mm I.D., 5 microm) using a mobile phase composed of 2% methanol and 98% aqueous citrate buffer at pH 3.0. A careful solid-phase extraction procedure, based on mixed-mode reversed-phase - strong anion exchange Oasis cartridges (MAX, 30 mg, 1 mL), was developed for the pre-treatment of plasma samples. Extraction yields were satisfactory, always higher than 90%. Calibration curves were linear over the 0.2-40.0 ng mL(-1) concentration range for MHPG and over the 0.5-40.0 ng mL(-1) concentration range for VMA. The method was successfully applied to plasma samples of former drug users undergoing detoxification therapy and subjects "at risk" of developing drug addiction.
...
PMID:Fast analysis of catecholamine metabolites MHPG and VMA in human plasma by HPLC with fluorescence detection and a novel SPE procedure. 1917 18

A rapid and selective method for simultaneous determination of cyclophosphamide and its metabolite carboxyethylphosphoramide mustard (CEPM) was developed using online sample preparation and separation with tandem mass spectrometric detection. Diluted plasma was injected onto an extraction column (Cyclone MAX 0.5 mm x 50 mm, >30 microm), the sample matrix was washed with an aqueous solution, and retained analytes were transferred to an analytical column (Gemini 3 microm C18 110A, 100 mm x 2.0 mm) using a gradient mobile phase prior to detection by MS/MS. Analytes were detected in an API-3000 LC-MS/MS system using positive multiple-reaction monitoring mode (m/z 261/140 and 293/221 for CTX and CEPM, respectively). Online extraction recoveries were 76% and 72% for cyclophosphamide and CEPM. Within-day and between-day variabilities were <3.0%, and accuracies were between -6.9% and 5.2%. This method has been used to measure plasma cyclophosphamide and CEPM concentrations in an ongoing Phase II study in children with newly diagnosed medulloblastoma.
...
PMID:Simultaneous determination of cyclophosphamide and carboxyethylphosphoramide mustard in human plasma using online extraction and electrospray tandem mass spectrometry (HTLC-ESI-MS/MS). 1944 87

Using isotope internal standard dilution technique, a high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed for the identification and quantitative determination of ciprofloxacin residue in the tissues of various fishes/shellfishes. The homogenized tissue sample added with ciprofloxacin-D8 and phosphate buffer solution (pH 7.0) was extracted with acetonitrile under ultrasonication, and degreased with hexane. After solid-phase extraction (SPE) was performed on an Oasis MAX cartridge, the sample was separated on a Cloversil-C18 column (150 mm x 4.6 mm, 5 microm) by using the mobile phase consisting of CH3CN-0.05% CF3 COOH (25:75, v/v). The detection was carried out by LC-MS/MS using an electrospray ionization interface in multiple reaction monitoring (MRM) mode. The quantification using isotope-labelled internal standard was based on the peak area ratio of ciprofloxacin and deuterated internal standard in the MRM mode. The calibration curve was linear within the range of 0.1 - 50.0 microg/kg and the limit of quantification was 0.1 microg/kg (S/N > or = 10). The recovery was between 92.5% and 98.1%, and the relative standard deviation was less than 4.3%. The application of this method was further demonstrated by analyzing ten various real samples from local markets. The results show that this method is sensitive, accurate and suitable for the confirmative determination of ciprofloxacin residues.
...
PMID:[Determination of ciprofloxacin residue in fish/shellfish tissues using liquid chromatography-tandem mass spectrometry with isotope internal standard dilution technique]. 1944 38

This paper presents the development of a simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to determine corticosteroids in bovine urine sample matrices. This method uses a single phase extraction (SPE) for cleaning of the sample with an Oasis MAX cartridge at pH 9.0-9.5 and elution by a neutral organic solvent (acetonitrile/dichloromethane), followed by separation on a GEMINI C18 column in the gradient mode with acetate buffer (pH 4.1)/methanol. A triple quadrupole mass spectrometer equipped with a multimode ion source, set to negative atmospheric pressure chemical ionization (APCI) in the multiple reaction monitoring mode was used for detection. The main advantage of this method over other commonly used methods includes the use of SPE with a low volume cartridge for sample preparation and no ion suppression effects from matrix components of the urine samples in the LC-MS/MS analysis. This allowed a reduction the quantification limits (decision limits, CCalpha) for the first time to 0.1 microg/L (1 and 0.2 microg/L for triamcinolone and flumethasone, respectively). The developed method was validated in accordance with the European Union Commission Decision 2002/657 EC. The recoveries and within-laboratory reproducibility varied from 77% to 115% and 87% to 107.5%, respectively, at 2, 3, and 4 microg/L levels of corticosteroids. The relative standard deviation (RSD) of the measurements was lower than 30%. The decision limit was calculated by multiplying the signal-to-noise ratio by 3 and the obtained values were in the range of 0.1-1.0 microg/L, confirmed by the analysis of twenty blank samples, which were spiked at the desired concentrations. The detection capability was calculated by the addition of the decision limit and the standard deviation followed by multiplication by 1.64 of the within-laboratory reproducibility at 2 microg/L of corticosteroids. The method was applied to four urine samples, giving concentrations of prednisolone (PRED) residues in the range from 0.3 to 0.9 microg/L.
...
PMID:Quantification of corticosteroids in bovine urine using selective solid phase extraction and reversed-phase liquid chromatography/tandem mass spectrometry. 2045 14

A sensitive and rapid HTLC-ESI-MS/MS method with an advanced online sample preparation was developed for determination of the gamma-secretase inhibitor MK-0752 in human plasma using an internal standard. Plasma samples (100 microL) were diluted and injected directly onto an online extraction column (Cohesive Cyclone MAX 0.5 mm x 50 mm, > 30 microm), the sample matrix was washed out with an aqueous solution, and retained analytes were eluted out and transferred directly to the analytical column (Phenomenex Gemini 3 micron C18 110A, 50 mm x 2.0 mm at 50 degrees C) for separation using a gradient mobile phase. The eluted analytes were then detected on an API-3000 LC-MS/MS System with ESI and a negative multiple reaction monitoring mode. The monitored ion transitions were m/z 441-->175 for MK-0752 and 496-->175 for the internal standard. Online extraction recoveries were 81%. The method was validated and was linear in the range of 0.05-50 microg/mL. Within-day and between-day precisions were<8.6%, and accuracies were 0.7 and 7.1%. This method was applied to the measurement of plasma MK-0752 levels in a Phase I study of pediatric patients with recurrent or refractory brain tumors.
...
PMID:Determination of the gamma-secretase inhibitor MK-0752 in human plasma by online extraction and electrospray tandem mass spectrometry (HTLC-ESI-MS/MS). 2070 49


1 2 3 Next >>