Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UNIPROT:P50583 (
asymmetrical
)
12,197
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Oxygen is believed to be one of the potential causative agents for the development of nuclear cataract following vitrectomy. The aim of this study was to determine the partial pressure of oxygen (pO2) in different compartments of the rabbit eye, and to describe the changes following vitrectomy. Twenty-six rabbits (3.5-5.3 kg) were anesthetized and oxygen tension was probed using a fiber-optic oxygen sensor system (optode). A micromanipulator was employed to ascertain the exact position of the probe within the eye. Measurements were taken pre- and post-vitrectomy at several defined positions within the vitreous, the lens and the anterior chamber. Follow-up measurements were performed 2 and 8 weeks after vitrectomy. The contralateral eye served as a control. Measurements in the normal rabbit eye showed that oxygen tension in the globe is
asymmetrical
with the lowest pO2 in the nucleus of the lens (10.4 mmHg+/-3.0). The region of the lens near the posterior capsule has an oxygen tension close to the values of the vitreous directly behind the posterior capsule (12.4 mmHg+/-3.1). The highest pO2 within the posterior compartment of the eye was measured close to the retinal surface (40-l60 mmHg) depending on neighboring large vessels. The tension drops off rapidly to 20 mmHg some 0.5 mm from the retina. From that position to the posterior surface of the lens there is a shallow gradient of decreasing pO2. Immediately following vitrectomy the pO2 in the
BSS
replacement varied from ca. 90-140 mmHg, and decreased over approximately 30 min. to levels that were 2-3 times that of normal vitreous. Two weeks after vitrectomy the pO2 values in the lens were 2-3 times as high as in the control eye (p < 0.05). In addition there is no longer a gradient in the vitreous cavity, except close to the retina. Eight weeks after vitrectomy, pO2 levels in the lens were decreased but still remained higher than in the normal eye (13.83 mmHg+/-0.02). The pO2 gradient in the vitreous was not detectable anymore. Overall the results provide evidence that oxygen levels in the lens increase significantly after vitrectomy in rabbits. If this occurs in humans it may contribute to cataract formation following surgery.
...
PMID:Oxygen tension in the rabbit lens and vitreous before and after vitrectomy. 1505 73
This letter suggests two new types of
asymmetrical
higher-order kernels (HOK) that are generated using the orthogonal polynomials Laguerre (positive or right skew) and Bessel (negative or left skew). These skewed HOK are implemented in the blind source separation/independent component analysis (
BSS
/ICA) algorithm. The tests for these proposed HOK are accomplished using three scenarios to simulate a real environment using actual sound sources, an environment of mixtures of multimodal fast-changing probability density function (pdf) sources that represent a challenge to the symmetrical HOK, and an environment of an adverse case (near gaussian). The separation is performed by minimizing the mutual information (MI) among the mixed sources. The performance of the skewed kernels is compared to the performance of the standard kernels such as Epanechnikov, bisquare, trisquare, and gaussian and the performance of the symmetrical HOK generated using the polynomials Chebyshev1, Chebyshev2, Gegenbauer, Jacobi, and Legendre to the tenth order. The gaussian HOK are generated using the Hermite polynomial and the Wand and Schucany procedure. The comparison among the 96 kernels is based on the average intersymbol interference ratio (AISIR) and the time needed to complete the separation. In terms of AISIR, the skewed kernels' performance is better than that of the standard kernels and rivals most of the symmetrical kernels' performance. The importance of these new skewed HOK is manifested in the environment of the multimodal pdf mixtures. In such an environment, the skewed HOK come in first place compared with the symmetrical HOK. These new families can substitute for symmetrical HOKs in such applications.
...
PMID:New Families of Skewed Higher-Order Kernel Estimators to Solve the BSS/ICA Problem for Multimodal Sources Mixtures. 2965 83