Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UNIPROT:P50583 (
asymmetrical
)
12,197
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
A model of the pulmonary airways was used to study three single-breath indices of gas mixing, dead space (VD), slope of the alveolar plateau, and alveolar mixing inefficiency (AMI). In the model, discrete elements of airway volume were represented by nodes. Using a finite difference technique the differential equation for simultaneous convection and diffusion was solved for the nodal network. Conducting airways and respiratory bronchioles were modeled symmetrically, but alveolar ducts asymmetrically, permitting interaction between convection and diffusion. VD, alveolar slope, and AMI increased with increasing flow. Similar trends were seen with inspired volume, although slope decreased at high inspired volumes with constant flow. VD was affected most by inspiratory flow and AMI and alveolar slope by expiratory time. VD fell approximately exponentially with time of
breath holding
. Eight different breathing patterns were compared. They had a small effect on alveolar slope and AMI and a greater effect on VD. The model shows how series and parallel inhomogeneity occur together and interact in
asymmetrical
systems: the old argument as to which is the more important should be abandoned.
...
PMID:Effect of breathing pattern on gas mixing in a model with asymmetrical alveolar ducts. 396 8
Echo-dynamography (EDG) is a method for visualizing left ventricular (LV) blood flow based on cardiac Doppler measurement in which blood flow component perpendicular to the ultrasonic beam is deduced by applying fluid dynamics theories to two-dimensional (2D) distribution of blood flow component along the ultrasonic beam. EDG has been validated by numerical simulation and particle image velocimetry of model circulation. However, these validations were too simple to reproduce unstable and
asymmetrical
flow in a beating heart. In the present study, EDG is compared with three-directional (3D) blood flow distribution on the same plane obtained with phase contrast magnetic resonance angiography (PCMRA) for clinical validation. Moreover, the location and vorticity of the vortex flow in LV are measured quantitatively and the relation to echocardiographic parameters of systolic and diastolic functions is discussed. 3D components of blood flow on a plane were obtained with triple scans of the same plane with ECG trigger and
breath holding
; 1) phase encode (x-axis), 2) read out (y-axis) and 3) slice selection (z-axis). After the acquisition of MRA dataset, color Doppler dataset of the same plane was acquired and 2D velocity distribution was obtained with EDG in MATLAB programs. EDG and PCMRA showed similar velocity vector distribution and formation of LV vortex flow. The vortex at mid diastolic phase was strongly affected by early diastolic filling while the vortex at isometric contraction was affected by atrial filling. EDG gained a new insight on systolic-diastolic coupling from the view point of LV blood flow such as LV vortex formation.
...
PMID:Evaluation of vortex flow in left ventricle by echo-dynamography and phase contrast magnetic resonance angiography. 2336 76