Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UNIPROT:P50502 (
Hip
)
7,003
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Polyetheretherketone (PEEK) is one of the up-to-date organic polymer thermoplastics with applications in orthopaedics and trauma medicine. This study presents a detailed analysis of its tests and applications in clinical medicine. A wide range of PEEK modifications and composites are commercially available, e.g., PEEK-Classix, PEEK-Optima, Endolign and Motis. They differ in their physical properties, which makes them suitable for different applications. Other forms, so-called PEEK bioactive composites, contain beta-tricalcium phosphate and hydroxyapatite. Research in this field is also concerned with the surface finish of this polymer thermoplastic and involves macroporous titanium and hydroxyapatite layers, or treatment with laser for an exactly defined surface structure. The clinical applications of PEEK and its composites include, in addition to components for spinal surgery, osteosynthesis plates, screws, intramedullary nails or external fixators, which are implants still at the stage of prototypes. In this review, attention is paid to the use of PEEK thermoplastics for joint replacement. Mid-term studies involving hundreds of patients have shown that, for instance, the VerSys Epoch Fullcoat
Hip
System (Zimmer) has a markedly lower stress-shielding effect.
Carbon
fibre-reinforced (CFR-PEEK) composites are used to make articulating components for total hip replacement. Their convenient properties allow for production of much thinner liners and an enlargement of the femoral head diameter, thus reducing the wear of joint implants. CFR-PEEK composites are particularly effective for hip resurfacing in which the Mitch PCR (Stryker) acetabular component has been used with good results. The MOTIS polymer acetabular cup (Invibio Ltd.) is another example. Further PEEK applications include the construction of finger-joint prostheses (Mathys AG), suture anchors (Stryker) and various kinds of augmentations (Medin). Based on the information obtained, the authors suggest further use for CFR-PEEK composites, such as the construction of articulating liners for total shoulder joint replacement, particularly in reverse shoulder arthroplasty.
...
PMID:[Polyetheretherketone (PEEK). Part II: application in clinical practice]. 2122 26
Carbon
fiber running-specific prostheses (RSPs) have allowed individuals with lower extremity amputation (ILEA) to participate in running. It has been established that as running speed increases, leg stiffness (Kleg) remains constant while vertical stiffness (Kvert) increases in able-bodied runners. The Kvert further depends on a combination of the torsional stiffnesses of the joints (joint stiffness; Kjoint) and the touchdown joint angles. Thus, an increased understanding of spring-like leg function and stiffness regulation in ILEA runners using RSPs is expected to aid in prosthetic design and rehabilitation strategies. The aim of this study was to investigate stiffness regulation to various overground running speeds in ILEA wearing RSPs. Eight ILEA performed overground running at a range of running speeds. Kleg, Kvert and Kjoint were calculated from kinetic and kinematic data in both the intact and prosthetic limbs. Kleg and Kvert in both the limbs remained constant when running speed increased, while intact limbs in ILEA running with RSPs have a higher Kleg and Kvert than residual limbs. There were no significant differences in Kankle, Kknee and touchdown knee angle between the legs at all running speeds.
Hip
joints in both the legs did not demonstrate spring-like function; however, distinct impact peaks were observed only in the intact leg hip extension moment at the early stance phase, indicating that differences in Kvert between limbs in ILEA are due to attenuating shock with the hip joint. Therefore, these results suggest that ILEA using RSPs has a different stiffness regulation between the intact and prosthetic limbs during running.
...
PMID:Amputee locomotion: spring-like leg behavior and stiffness regulation using running-specific prostheses. 2395 71