Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UNIPROT:P50502 (Hip)
7,003 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

The reaction of the renin-angiotensin system to acute angiotensin converting enzyme inhibition was investigated in a single-blind, crossover study in nine normal volunteers receiving two out of three regimens in random order: the new converting enzyme inhibitor benazepril (20 mg once or 5 mg four times at 6-hour intervals) or enalapril (20 mg). Plasma converting enzyme activity, drug levels, angiotensin I and angiotensin II, active renin, and aldosterone were measured before and 1-4 hours and 14-30 hours after drug intake. Baseline in vitro plasma converting enzyme activity was 97 +/- 15 nmol/ml/min (mean +/- SD) when Hip-Gly-Gly was used as substrate, but with carbobenzoxy-Phe-His-Leu (Z-Phe-His-Leu) or angiotensin I as substrate it was only 20 +/- 4 and 1.7 +/- 0.3 nmol/ml/min, respectively. Discriminating power at peak converting enzyme inhibition was enhanced with the two latter substrates. In vivo converting enzyme activity was estimated by the plasma angiotensin II/angiotensin I ratio, which correlated well with in vitro converting enzyme activity using Z-Phe-His-Leu as substrate (r = 0.76, n = 252). Angiotensin II levels returned to baseline less than 24 hours after drug administration, whereas in vitro and in vivo converting enzyme activity remained considerably inhibited and active renin together with angiotensin I levels were still elevated. A close linear relation was found between plasma angiotensin II and the angiotensin I/drug level ratio (r = 0.91 for benazeprilat and r = 0.88 for enalaprilat, p less than 0.001). Thus, plasma angiotensin II truly reflects the resetting of the renin-angiotensin system at any degree of converting enzyme inhibition. The ratio of plasma angiotensin II to angiotensin I represents converting enzyme inhibition more accurately than in vitro assays, which vary considerably depending on substrates and assay conditions used.
...
PMID:Determinants of angiotensin II generation during converting enzyme inhibition. 217 61

A highly sensitive assay for angiotensin I converting enzyme has been developed by using angiotensin I as a substrate. Angiotensin II generated in the reaction mixture was measured by a newly developed specific radioimmunoassay. To protect against angiotensin II destruction, bestatin, an inhibitor of renin, was also used to inhibit plasma renin activity. The reaction was stopped by adding EDTA and MK-521, inhibitors of angiotensin I converting enzyme. The specificity of the antiserum used for the angiotensin II radioimmunoassay was very high. The cross reactivity with angiotensin I was less than 0.5% and none of the proteolytic enzyme inhibitors crossreacted in the assay. The inhibitory effect of pepstatin on plasma renin activity was very high (more than 80%) under the standard assay conditions employed. Serum angiotensinase activity was completely inhibited by the addition of bestatin. An excellent correlation was obtained between this new method and the spectrophotometric method using a synthetic substrate, Hip-His-Leu. The generation of as little as 12 pM of Angiotensin II can be detected. Such low concentration have not been measurable with the usual spectrophotometric method. This new method will facilitate clinical and experimental studies on this unique enzyme, since very low levels of activity can be determined by this highly sensitive radioimmunoassay for angiotensin II.
...
PMID:An improved method for measuring angiotensin I converting enzyme activity using a highly sensitive angiotensin II radioimmunoassay. 300 65