Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UNIPROT:P30536 (PBS)
9,886 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

A novel label-free amperometric immunosensor for the detection of rubella vaccine was developed by immobilizing anti-rubella serum on bilayer nano-Au/polymerized o-phenylenediamine film with electrodeposited Prussian Blue (PB) as an electrode transfer mediator on the platinum electrode. The redox reactions of PB as a probe on the platinum surface were blocked due to the binding of the antibody to the antigen, which was investigated by cyclic voltammetry. Therefore, the interaction of the antibody with various concentrations of antigen could be detected by measurements of amperometric response in PBS, and the amperometric response on the surface of the modified electrode was inversely proportional to the concentration of rubella vaccine in the sample. The immunosensor showed a specific response to rubella vaccine in the range 8.1x10(-8)-8.0x10(-6) lgCCID50/ml (cell culture infectious dose) and a detection limit of 4.010(-8) lgCCID50/ml at a signal-to-noise ratio of 3. To summarize, the present work provides a low-cost, fast response time, highly sensitive and easy-to-prepare method for the determination of antigen in biological products.
...
PMID:A new label-free amperometric immunosenor for rubella vaccine. 1576 42

The structure and dynamic organization of a mixed Langmuir film of glucose oxidase (GOx) and lipid at the air-water interface were studied. The film was transferred onto the Prussian Blue (PB)-modified Pt electrode for biosensor preparation. The PB modified electrode showed well defined redox peaks in 0.1 M PBS electrolyte. The Langmuir film was characterized at the air-water interface by pi-A isotherms. The mixed monolayer was formed by spreading GOx on the LB trough covered with lipid. Time-pressure results show that at least 90 minutes are required to reach the equilibrium state of GOx-lipid film. The monolayer was transferred onto the PB-modified electrode when surface pressure was 40 mN/m. This sensor was characterized by a very low detection limit and a wide linear range. The optimal conditions for both fabricating and response of the sensor were investigated. The proposed biosensor showed a linear calibration range from 5 x 10(-6) to 6 x 10(-5) M. The detection limit was determined to be 1.5 x 10(-6) M.
...
PMID:Glucose sensor based on glucose oxidase-lipid LB film immobilized in Prussian Blue layer. 1904 54