Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UNIPROT:P17174 (
aspartate aminotransferase
)
14,872
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Hepatic function of 80 children aged under 3 years with Plasmodium vivax malaria were studied during the acute attack and 6 weeks after antimalarial treatment. Raised levels of serum
aspartate transaminase
(serum AST; SGOT), serum alanine transaminase (serum ALT; SGPT), and
alkaline phosphatase
were observed in 68%, 39% and 46% of cases respectively. AST levels were higher than ALT ones and the mean level of both enzymes was much higher in patients with hepatomegaly. The hepatic dysfunction which these observations reflect is transient, as these enzymes were found to be at their normal levels 6 weeks after treatment. A transient derangement of liver function is thus a common feature of childhood malaria, and hepatic dysfunction takes place to a significant degree even in P. vivax malaria.
...
PMID:Hepatic dysfunction in childhood malaria. 37 43
This article discusses the effects of Fructus Gardeniae extract on hepatic function. Fructus Gardeniae extract manifested no hepatotoxic effects on rats, as shown by
alkaline phosphatase
,
aspartate aminotransferase
, and lactate dehydrogenase studies. Fructus Gardeniae extract failed to activate the UDP-glucuronyltransferase system; whereas in hyperbilirubinemic state the enzyme was activated, presumably by substrate induction. Fructus Gardeniae extract increased the activity of UDP-glucose dehydrogenase, which would result in an increase in availability of UDP-glucuronic acid intracellularly, BSP clearance study showed an unexpected impairment of hepatic uptake of the dye after extract treatment. The action mechanism involved in lowering of serum bilirubin level by Fructus Gardeniae extract may well be complex; it is probably acting on a locus other than glucuronyl transferase.
...
PMID:Effects of Fructus gardeniae extract on hepatic function. 41 32
Low turbidity, "clear" enzyme controls commercially produced in three concentrations and conventional human lyophilized control sera, which are more turbid, were evaluated to determine which was superior for quality control purposes. Criteria used to evaluate the controls were: 1) turbidity measurement, 2) daily assays for 30 days to estimate day-to-day precision, and 3) stability of the enzyme assay value for these controls when they were reconstituted and frozen for 0 to 30 days and 0 to 10 days with three aliquots separately prepared and frozen for 0 to 10 days for a total of 30 days. The controls were analyzed for lactate dehydrogenase, alanine aminotransferase,
aspartate aminotransferase
, creatine kinase, and
alkaline phosphatase
activities with the Perkin-Elmer KA 150 enzyme analyzer.
...
PMID:The use of "clear" enzyme control materials. 42 91
The effects of three widely spaced levels of bacterial contamination of reagent water on several chemistry, radioimmunoassay, and coagulation procedures were studied. These included determinations of lactate dehydrogenase, creatine kinase,
aspartate transaminase
,
alkaline phosphatase
, blood urea nitrogen, total protein, thyroid-stimulating hormone, digoxin, thrombin time, activated partial thromboplastin time, and prothrombin time. Statistical analyses included calculations of means and coefficients of variation, and analysis of variance, as well as correlation coefficients for test results versus logarithm of bacterial contamination. Statistically and clinically significant differences occurred together only for an elevated level of creatine kinase.
...
PMID:Effects of bacterial contamination of reagent water on selected laboratory tests. 43 36
Normal values for 13 chemical constituents of plasma were estimated from results for 837 presumably healthy children. Ninety microliters of specimen was analyzed for lactate dehydrogenase,
aspartate aminotransferase
,
alkaline phosphatase
, inorganic phosphorus, total calcium, total cholesterol, total proteins, albumin, uric acid, urea nitrogen, alanine aminotransferase, total bilirubin, and glucose. We used two Abbott ABA-100 Bichromatic Analyzers interfaced directly to the ABA Data Management System. For each test age- and sex-related variations were assessed and normal values were estimated for six different age groups.
...
PMID:Microchemical analysis for 13 constituents of plasma from healthy children. 43 35
In order to verify the influence of sampling time on blood constituents, populations of supposedly healthy subjects were grouped according to age, sex, deviation from their ideal weight, state of fasting or nonfasting, and time of sampling. Each fasting subject in one group underwent two samplings during the course of a morning: the first at 08.00 and the second between 09.00 and 12.00. In the second group, the first was taken at 13.00, and the second between 14.00 and 16.00. Subjects in the second group had eaten a standard meal of 700 calories at 12.00. Differences between the paired samples from a given individual are discussed with respect to the time of sampling for plasma urea, creatinine, proteins, albumin, calcium, sodium, potassium, cholesterol, uric acid, chloride ions, phosphate, bilirubin,
aspartate aminotransferase
, alanine aminotransferase, lactate dehydrogenase, creatine phosphokinase,
alkaline phosphatase
, hemoglobin and erythrocyte and leukocyte counts. Variations due to the time of sampling were large for phosphorus, bilirubin, and leukocyte count.
...
PMID:The effect of sex, deviation from ideal weight and sampling time on blood constituents in presumably healthy subjects. 43 75
A pattern of results is reported which was found to be common among patients who had intrahepatic cholestasis (IHC) which was rarely found in patients with other hepatic conditions. The pattern was recognized from over 1000 cases suspected of hepatobiliary disease. 29 were diagnosed with IHC, and excluding 4, 25 revealed the following etiological pattern: chlorpromazine (12 patients); pregnancy and oral contraceptive use (8); and other (5). As opposed to patients with acute and chronic hepatic disease, IHC sufferers had relatively normal values for immunoglobulins and antibody titers. A disproportionate elevation of serum bilirubin vis-a-vis serum enzymatic activities separated potential IHC cases into intra- and extrahepatic cholestasis. The following factorial evaluations were useful in distinguishing hepatic disease states: 1) when the sum of the activities of serum
alkaline phosphatase
, 5'-nucleotidase, aspartate and alanine amiotransferases, and isocitrate dehydrogenase was divided by the serum bilirubin concentration, there was good resolution of the distinction between patients with IHC and those with primary biliary cirrhosis, early and late viral hepatitis, cholelithiasis, and pancreatic and bile duct cancers. 2) Resolution was also achieved when the numerator included
alkaline phosphatase
, 5'-nucleotidase, and
aspartate aminotransferase
, but not when
alkaline phosphatase
alone, or
alkaline phosphatase
combined with 5'-nucleotidase, was used. The essential lesion in IHC is an excretory defect.
...
PMID:Biochemical features of intrahepatic cholestasis. 45 73
The overall performances of several enzyme reagent kits for
alkaline phosphatase
, creatine kinase, lactic dehydrogenase, and
aspartate aminotransferase
were evaluated using an ABA-100 Bichromatic Analyzer. Interassay precision using this instrument with commercial reagents compared well with published data for similar analyses performed at university hospitals and referral laboratories. Significantly poorer precision with lower limits of linearity was observed when reagents recommended for use at 30 C were used at 37 C. Significant differences in measured levels of creatine kinase, lactic dehydrogenase, and
aspartate aminotransferase
due to different lots of expendable cuvettes were found for elevated levels of these enzymes. All kit reagents met manufacturers' claims for stability; however, different absolute levels of lactic dehydrogenase were observed with one kit reagent on successive days. Slight hemolysis affected creatine kinase levels measured with some reagent kits significantly more than others.
...
PMID:Evaluation of commercial enzyme reagent kits by use of a semiautomated chemistry analyzer. 47 90
Sets of survey specimens having known linear interralationships were analyzed on four occasions by approximately 450 laboratories for the five enzymes lactate dehydrogenase,
aspartate aminotransferase
, creatine kinase, alanine aminotransferase, and
alkaline phosphatase
. The results are summarized in terms of the apparent precision and relative accuracy of various analytical systems, and some apparent problems in enzyme assays are identified. The results show that interlaboratory differences in enzyme analyses are not due primarily to differences in the way laboratorians utilize their analytical systems but rather are due to fundamental differences in the instruments and reagents supplied to the laboratorians. The attainment of interlaboratory comparability of enzyme analyses is a problem that can best be addressed by the manufacturers of instruments and reagents, rather than by individual laboratorians.
...
PMID:The 1978 College of American Pathologists survey of analyses of five serum enzymes by 450 laboratories. 47 5
1. Enzyme activities were studied in blood plasma from Rhenish, Italian, Landes and Masseubian geese. 2. Strains used for liver production (Landes, Masseubian) showed higher activities of
aspartate transaminase
(
AST
) [EC 2.6.1.1], alanine transaminase (ALT) [EC 2.6.1.2] and fructose aldolase (FRA) [EC 4.1.2.13] while breeds with high egg production (Rhenish, Italian) had higher activities of both
alkaline phosphatase
(
ALP
) [EC 3.1.3.1] and acid phosphatase (ACP) [EC 3.1.3.2]
...
PMID:Blood enzyme activities in different breeds of geese. 49 70
<< Previous
1
2
3
4
5
6
7
8
9
10
Next >>