Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UNIPROT:P17174 (
aspartate aminotransferase
)
14,872
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
A comparison of the cost of laboratory-made reagents with that of commercial kits was made for three serum-enzyme estimations and three serum-hormone estimations. The cost of reagents in
kit
form could only be justified on economic grounds for serum
aspartate transaminase
, alanine transaminase, and lactic dehydrogenase if the laboratory performed less than about 35 tests per day. It is unlikely that the use of kits for serum tri-iodothyronine, thyroxine, and thyrotrophic hormone can be justified on economic grounds for any workload. It is estimated that between 2 million pounds and 3 million pounds is spent unnecessarily by the National Health Service each year to purchase commercially prepared reagents for the six tests studied.
...
PMID:Comparison of cost of preparing reagents in laboratory with cost of using commercial kits. 7 63
The overall performances of several enzyme reagent kits for alkaline phosphatase, creatine kinase, lactic dehydrogenase, and
aspartate aminotransferase
were evaluated using an ABA-100 Bichromatic Analyzer. Interassay precision using this instrument with commercial reagents compared well with published data for similar analyses performed at university hospitals and referral laboratories. Significantly poorer precision with lower limits of linearity was observed when reagents recommended for use at 30 C were used at 37 C. Significant differences in measured levels of creatine kinase, lactic dehydrogenase, and
aspartate aminotransferase
due to different lots of expendable cuvettes were found for elevated levels of these enzymes. All
kit
reagents met manufacturers' claims for stability; however, different absolute levels of lactic dehydrogenase were observed with one
kit
reagent on successive days. Slight hemolysis affected creatine kinase levels measured with some reagent kits significantly more than others.
...
PMID:Evaluation of commercial enzyme reagent kits by use of a semiautomated chemistry analyzer. 47 90
The expert group "Drug Interference in Clinical Chemistry" of the Bureau of Reference, Directorate General for Research, Science and Education of the Commission of the European Communities, consisting of one participant of each member of the European Communities, presents this first report on the final results of its activities. Within the framework of a first stage basic program, the paper describes interferences of therapeutic and elevated doses of ascorbic acid on commonly used clinical chemical methods. This is the result of a bipartite study that was jointly planned, carried out and evaluated. Local and personal influences have been eliminated, as have variations due to methodology, measurement equipment and reagents, in order to be able to present distinct causal effects of ascorbic acid. No definite influence of ascorbic acid on analytical values for urea, cholesterol, calcium, protein, bilirubin,
aspartate aminotransferase
and alkaline phosphatase could be detected. At therapeutic concentrations, ascorbic acid distinctly interferes with the analysis of glucose, uric acid, creatinine and inorganic phosphate. The extent and direction of interferences vary, depending on the type of reaction,
kit
and apparatus. In some cases the influence of ascorbic acid results in severe disturbance of the analytical methods leading to useless values.
...
PMID:Drug interference in clinical chemistry: studies on ascorbic acid. 62 9
Sources of variation in assays of
aspartate aminotransferase
(EC 2.6.1.1) activity were examined in an interlaboratory survey and through an examination of materials used as calibration materials in these assays. Four highly stable lyophilized specimens containing human cytoplasmic enzyme, with activities of 0, 22, 46, and 96 U/liter at 30 degrees C and optimal substrate concentrations, were assayed by 319 laboratories. Mean values obtained on these specimens by laboratories using 2,4-dinitrophenylhydrazine kits varied among manufacturers and deviated from values expected from this procedure. The average coefficient of variation (CV) with these kits was greater than 20%. Automated continuous-flow procedures with use of diazonium salt showed the best precision (av CV, less than 10%). However, the automated continuous-flow malate dehydrogenase/NADH coupled method produced an average CV greater than 20%. Results from each of the automated methods were related to a reference malate dehydrogenase/NADH coupled continuous kinetic assay method by temperature relationships alone. Mean values from manual diazonium salt procedures were 1.7-fold greater than similar reference values (av CV was 18%). The higher results were attributed to the use of poorly-defined units and to an artifact caused by chromophore stabilizers in this procedure when aqueous samples are used. The average CV in continuous kinetic methods varied among
kit
manufacturers, ranging from 6 to 28% for the specimen of highest activity. Variations in results were much larger at 366 nm than at 340 nm than at 340ity. Variations in results were much larger at 366 nm than at 340 nm. Interassay relationships of these methods are presented. Concentrations of pyruvate in commercially available calibration materials differed between manufacturers, varied in stability, and deviated from the expected concentration. For some colorimetric assays the precision attained on reported absorbance values for the enzyme specimens was of the same order of magnitude as that for pyruvate standards. Other sources of error are revealed by the interlaboratory survey. The value of commercially available sources of enzyme activity as calibration or control materials was assessed by evaluating the following properties: activity at suboptimal concentrations of L-aspartate or 2-oxoglutarate, temperature effects, preincubation lability owing to aspartate and phosphate, pyridoxal phosphate saturation, contamination with glutamate dehydrogenase, and manufacturer's rated activity. These properties are compared to those of human cytoplasmic enzyme in a human serum matrix.
...
PMID:Interlaboratory proficiency, intermethod comparison, and calibrator suitability in assay of serum aspartate aminotransferase activity. 113 21
Forty-three kits for clinical chemical analysis of GOT (
aspartate aminotransferase
) were evaluated. The reference method was the kinetic method performed on the Abott ABA-100 Bichromatic Analyzer. Specific data are tabulated for each
kit
and include ease and speed of testing and performance data. Most kits failed to provide completely adequate labelling information. Reproducibility CV for the kits varied widely (4.20 to 21.26 for the normal pool and 1.57 to 20.51 for the high pool). Many kits gave significant numbers of false positive and false negative results on patient samples. There is a need for manufacturers to either derive their own normal ranges or to establish exact equivalency values with the method used to establish the normal values. No difference was demonstrated between performance by two skilled technologists. However, we did detect lot-to-lot variation and differences in performance between narrow bandpass and wide bandpass spectrophotometers.
...
PMID:Performance of "kits" used for clinical chemical analysis of GOT (aspartate aminotransferase). 126 Oct 5
Two hundred and forty-three patients receiving renal replacement therapy (RRT) and 20 renal unit staff were tested for antibodies to hepatitis C (HCV). Three patients (1.2%) were positive by the first generation test
kit
, the lowest rate in patients receiving RRT reported in the literature to date. These three, and eight other patients tested positive by the second generation
kit
, a prevalence rate of 4.5%. Anti-HCV antibody positivity was associated with higher mean serum alanine aminotransferase (p = 0.0003) and
aspartate aminotransferase
(p = 0.018) levels. However, only one of the 11 anti-HCV positive patients had liver transaminase levels more than twice the upper limit of the laboratory reference range. Anti-HCV positivity was associated with a higher mean number of units of blood transfused (p = 0.035). None of 20 staff were anti-HCV positive. Twenty-five of 212 (11.7%) patients reported a history of liver disease; none of these were anti-HCV positive. Hepatitis B surface antigen was detected in eight of 215 (3.7%) patients, of which three were e antigen positive. There was evidence of past hepatitis B infection in 53 of 215 (24.7%) patients, more frequently in Maoris (p = 0.001). Overall, significantly raised liver transaminases were present in three of 198 (1.5%) patients and in no staff. This unit has a remarkably low prevalence of antibodies to HCV, an observation supported by the low rate of abnormal serum liver enzymes.
...
PMID:Prevalence of antibodies to hepatitis C virus in patients receiving renal replacement therapy, and in the staff caring for them. 128 95
Serum chemistry values were obtained from 64 adult San Joaquin
kit
foxes (Vulpes macrotis mutica) in western Kern County, California (USA). The goal of the study was to establish normal chemistry values for this endangered species. No significant differences were found for mean values of alanine aminotransferase (217.1 IU/l), alkaline phosphatase (44.2 IU/l), cholesterol (145.6 mg/dl), total protein (5.8 g/dl), creatinine (0.63 mg/dl), calcium (8.2 mg/dl), albumin (3.0 g/dl), glucose (129.2 mg/dl), amylase (196.8 IU/l), sodium (153.7 mEq/l) and phosphorus (5.42 mg/dl) between sexes or seasons. Significant differences were noted for
aspartate aminotransferase
, blood urea nitrogen and potassium between seasons. Possible disturbances in normal hepatic and renal functions were noted.
...
PMID:Serum chemistry values of the endangered San Joaquin kit fox (Vulpes macrotis mutica). 151 73
Kits of five different suppliers, composed according to the Dutch recommendations for determination of the enzyme activity of alanine aminotransferase,
aspartate aminotransferase
, lactate dehydrogenase, gamma-glutamyltransferase, alkaline phosphatase, and creatine kinase, were intercompared. Activity concentrations of the enzymes in human sera were measured under defined conditions, evaluated, and related to the actual composition of the kits. Concentrations of all
kit
components were determined by various analytical techniques. The overall results of the activity measurements and the composition of at least three kits inter-agree well. We found deviations as great as 10% in our analytical evaluation of the kits of the other two suppliers, which can partly be accounted for.
...
PMID:Kits for enzyme determinations compared: relation between composition and quality. 614 61
Every second traumatized patient is a chronic alcoholic. Chronic alcoholics are at risk due to an increased morbidity and mortality. Reliable and precise diagnostic methods for detecting alcoholism are mandatory to prevent posttraumatic complications by adequate prophylaxis. The patient's history, however, is often not reliable, and conventional laboratory markers are not sensitive or specific enough. The aim of this study was to investigate whether carbohydrate-deficient transferrin (CDT) is a sensitive and specific marker to detect alcoholism in traumatized patients. One hundred and five male traumatized patients or their relatives gave their written informed consent to participate in this institutionally approved study. All patients were transferred to the intensive care unit after admission to the emergency room, followed by surgical treatment. Diagnostics included an alcoholism-related questionnaire, conventional laboratory markers (mean corpuscular volume, gamma-glutamyltransferase,
aspartate aminotransferase
, and alanine aminotransferase), and CDT sampling (microanion-exchange chromatography, turbidimetry, and radioimmunoassay, respectively). Only patients in whom a reliable history could be obtained were included. Alcoholism was diagnosed if the patients met the Diagnostic and Statistical Manual of Mental Disorders criteria for chronic alcohol abuse or dependence. The administration of fluids before CDT sampling was carefully documented. Patients did not differ significantly regarding age, Trauma and Injury Severity Score, and Acute Physiology and Chronic Health Evaluation score. The sensitivity of the CDT research
kit
was 70% and of the commercially available
kit
CDTect was 65%. Early sampling in the emergency room and before administration of large volumes of fluid increased the sensitivity to 83% for the CDT research
kit
and 74% for CDTect, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)
...
PMID:Relevance of carbohydrate-deficient transferrin as a predictor of alcoholism in intensive care patients following trauma. 747 68
We designed and performed a multicenter clinical trial to determine the relationship between measurements of the level of the enzyme
aspartate aminotransferase
(
AST
) in gingival crevicular fluid (GCF) to other measures used to detect periodontal disease and monitor outcome of treatment, including pocket depth and gingival inflammation. 32 periodontitis patients were enrolled at the University of Washington, Seattle, 30 at the University of Florida, Gainesville, and 34 at the University of Illinois, Chicago. 10 periodontally normal control subjects were enrolled at each location. 8 diseased and 4 healthy sites were designated for study in each patient and 8 healthy sites designated in each control subject. Measures of disease included pocket depth, severity of gingival inflammation, and GCF volume.
AST
levels were measured using the PerioGard test
kit
. Clinical measurements were made and GCF samples harvested and tested 2x before and 2x after therapy consisting of scaling and root planing under local anesthetic. Specific design and other issues are discussed, including selection of patients and control subjects, sample size, selection of experimental test sites, methods for assessment of diseased and therapeutic improvement, harvesting of GCF and selection of appropriate biostatistical methods for data analysis. Demographics of the patient populations at the 3 locations are reported. As expected, therapy induced only negligible changes in the measures of disease at healthy sites in control subjects, and relatively minor improvement in healthy sites in patients. In contrast, statistically significant improvement relative to pretreatment baseline status in all 3 measures of disease was observed for diseased sites at all 3 study locations with all p-values less than 0.0002. The magnitude of improvement was comparable to that reported previously by others. The % of PerioGard-positive sites decreased significantly between the screening baseline and both post-treatment visits for patients at all 3 locations, with p values of 0.0001 to <0.0008.
...
PMID:A multicenter clinical trial of PerioGard in distinguishing between diseased and healthy periodontal sites. (I). Study design, methodology and therapeutic outcome. 868 27
1
2
3
4
5
Next >>