Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UNIPROT:P10636 (tau protein)
5,110 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Phosphorus-31 (31P) NMR is proving to be a powerful analytical method for investigating molecular/metabolic issues in neural tissues. Recent studies have demonstrated high levels of phosphomonoesters and phosphodiesters in mammalian brain, and revealed the influence of brain maturation, development, and aging on these levels. Preliminary studies in Alzheimer's disease have demonstrated elevated levels of phosphomonoesters and phosphodiesters in the areas of Alzheimer's brain which exhibit neuropathological changes. Moreover, phosphomonoester levels were also elevated in areas of Alzheimer's brain that were devoid of neuropathological changes. These findings suggest that the phosphomonoester elevations in Alzheimer's brain antedate changes in cellular morphology and structure. Abnormalities in protein kinase function could potentially explain these findings, as well as the reported hyperphosphorylation of tau protein in Alzheimer's brain. Recent studies from this laboratory suggest that aluminum could also be involved in the changes in phosphomonoesters and phosphodiesters.
...
PMID:31P nuclear magnetic resonance (NMR) spectroscopy of brain in aging and Alzheimer's disease. 331 99

Inductively coupled plasma mass spectrometry (ICP-MS) is used for phosphorus determination in protein samples. A small amount of solid protein sample (down to 1 micro g) or digest (1-10 micro L) protein solution was denatured in nitric acid and hydrogen peroxide by closed-microvessel microwave digestion. Phosphorus determination was performed with an optimized analytical method using a double-focusing sector field inductively coupled plasma mass spectrometer (ICP-SFMS) and quadrupole-based ICP-MS (ICP-QMS). For quality control of phosphorus determination a certified reference material (CRM), single cell proteins (BCR 273) with a high phosphorus content of 26.8+/-0.4 mg g(-1), was analyzed. For studies on phosphorus determination in proteins while reducing the sample amount as low as possible the homogeneity of CRM BCR 273 was investigated. Relative standard deviation and measurement accuracy in ICP-QMS was within 2%, 3.5%, 11% and 12% when using CRM BCR 273 sample weights of 40 mg, 5 mg, 1 mg and 0.3 mg, respectively. The lowest possible sample weight for an accurate phosphorus analysis in protein samples by ICP-MS is discussed. The analytical method developed was applied for the analysis of homogeneous protein samples in very low amounts [1-100 micro g of solid protein sample, e.g. beta-casein or down to 1 micro L of protein or digest in solution (e.g., tau protein)]. A further reduction of the diluted protein solution volume was achieved by the application of flow injection in ICP-SFMS, which is discussed with reference to real protein digests after protein separation using 2D gel electrophoresis.The detection limits for phosphorus in biological samples were determined by ICP-SFMS down to the ng g(-1) level. The present work discusses the figure of merit for the determination of phosphorus in a small amount of protein sample with ICP-SFMS in comparison to ICP-QMS.
...
PMID:Determination of phosphorus in small amounts of protein samples by ICP-MS. 1261 Jul 11