Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UNIPROT:P02794 (ferritin)
17,525 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

In a previous study, we used a murine monoclonal antibody, A7, against human colon carcinoma as a drug-carrier to treat colorectal cancer. In the present study, we found that MAb A7 also reacted immunohistochemically with 73% of human pancreatic carcinoma cell lines, with the A7 antigen mainly being detected on the cell surface. However, the A7 antigen was found in only 9% of the spent media of these human pancreatic carcinoma cell lines by ELISA. On the other hand, the positive incidence of CA19-9, POA, ferritin, CEA, DU-PAN-2 and SLX in those spent media was 100%, 64%, 64%, 55%, 55% and 36%, respectively. These results suggest that the A7 antigen may only rarely be shed into the sera of pancreatic cancer patients, in which case MAb A7 could be a suitable drug-carrier in targeting chemotherapy for pancreatic cancer patients.
...
PMID:Expression of the cell surface antigen detected by the monoclonal antibody A7 in pancreatic carcinoma cell lines. 132 20

The present study was designed to test the biocompatibility of a new vitamin E-modified multilayer membrane compared with highly biocompatible polysulphone dialyzer and acrylonitrile dialyzer. Thirty patients (mean age 53.2 +/- 15.3 SD years; dialytic age 36 +/- 5.6 months) were selected for the study. The study was divided into three periods of 6 months (phases A, B and C). In the first phase (from Jan. 1999 to June 1999) patients undergoing maintenance bicarbonate dialysis were randomly divided into three filter groups composed, respectively, of 10 patients: acrylonitrile group, polysulphone group and vitamin E-coated dialyzer group. In the phase B (from July 1999 to Dec. 1999) and in the phase C (from Jan. 2000 to June 2000), all three groups changed their own dialysis membranes. Vitamin E-coated dialyzer causes significant decreases in beta(2)-microglobulin, ferritin and immunoglobulin G, a normalization of complement C3 and an increase of plasmatic vitamin E compared to other filters. In the VE group homocysteine decreases but not in a significant manner. In addition, this dialyzer seems not to influence lipid pattern and protein-energy malnutrition parameters. These results clearly show a positive effect of this new filter in influencing different biochemical parameters, perhaps saving vitamin E and reducing polymorphonuclear cell activation.
...
PMID:Is the bioreactivity of vitamin-E-modified dialyzer an expression of increased plasmatic vitamin E concentration? 1221 39

Since hollow-fiber flow field-flow fractionation (HF FIFFF) utilizes a cylindrical channel made of a hollow-fiber membrane, which is inexpensive and simple in channel assembly and thus disposable, interests are increasing as a potential separation device in cells, proteins, and macromolecules. In this study, performance of HF FIFFF of proteins is described by examining the influence of flow rate conditions and length of fiber (polyacrylonitrile or PAN in this work) on sample recovery as well as experimental plate heights. The interfiber reproducibility in terms of separation time and recovery was also studied. Experiments showed that sample recovery was consistent regardless of the length of fiber when the effective field strength (equivalent to the mean flow velocity at the fiber wall) and the channel void time were adjusted to be equivalent for channels of various fiber lengths. This supported that the majority of sample loss in HF FIFFF separation of apoferritin and their aggregates may occur before the migration process. It is finally demonstrated that HF FIFFF can be applied for characterizing the reduction in Stokes' size of low density lipoproteins from blood plasma samples obtained from patients having coronary artery disease and from healthy donors.
...
PMID:Performance of hollow-fiber flow field-flow fractionation in protein separation. 1631 97