Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UNIPROT:P02794 (
ferritin
)
17,525
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Circulating serum transferrin receptor level was measured using mouse monoclonal antibody against transferrin receptor (
Orion
Diagnostica, Finland) in 126 patients with various disorders of erythropoiesis and the results were compared to those obtained form control group consisted of 30 healthy volunteers with normal iron stores. Serum transferrin receptor level was significantly elevated in patients with iron deficiency and in all patients with hyperplastic erythropoiesis (hereditary spherocytosis, immune hemolytic anemia, beta thalassemia, myelodysplasia). Measurement of circulating serum transferrin receptor level was a sensitive indicator of iron depletion as well as a helpful parameter in differential diagnosis between iron deficiency and anemia of chronic disease where circulating transferrin receptor level was not elevated. Index transferrin receptor/
ferritin
calculated as a ratio of circulating serum transferrin receptor level to log serum
ferritin
level was a more sensitive parameter than measurement of serum transferrin receptor not only for determination of patients with anemia of chronic disease, but also for discrimination of patients with elevated serum transferrin receptor level due to true iron deficiency from those with high serum transferrin receptor level caused by relative iron deficiency in hyperplastic erythropoiesis.
...
PMID:[Clinical importance of determining levels of circulating transferrin receptors in blood]. 1104 46
We have evaluated a newly introduced immunoturbidimetric transferrin receptor assay (IdeA TfR-IT,
Orion
Diagnostica, Finland) in healthy subjects and in a study population consisting of patients with rheumatoid arthritis and juvenile chronic arthritis. The IdeA TfR-IT assay was found to provide reproducible results which were in good agreement with the ELISA assays from
Orion
Diagnostica (IDeA-ELISA, correlation R2=0.8, n=102) and R&D systems (Quantikine TfR ELISA assay, correlation R2=0.95, n=39). The analysis of the patient samples suggested that, on the basis of serum transferrin receptor and
ferritin
concentrations, in approximately one third of patients with rheumatoid arthritis anemia is due to the depletion of iron stores. Apparently, in all patients with rheumatoid arthritis iron deficiency must be considered as a potential cause of the anemia. Now, that assays which are suitable for automated analyzers have become available for the measurement of serum transferrin receptor, this analyte has the potential to become a part of the routine evaluation of iron status.
...
PMID:Evaluation of iron status in anemic patients with rheumatoid arthritis using an automated immunoturbidimetric assay for transferrin receptor. 1120 97