Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UNIPROT:P02794 (ferritin)
17,525 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

The cell surface topology of various gram-negative and -positive, anaerobic and aerobic, mesophilic and thermophilic, cellulolytic and noncellulolytic bacteria was investigated by scanning electron microscopic visualization using cationized ferritin. Characteristic protuberant structures were observed on cells of all cellulolytic strains. These structures appeared to be directly related to the previously described exocellular cellulase-containing polycellulosomes of Clostridium thermocellum YS (E. A. Bayer and R. Lamed, J. Bacteriol. 167:828-836, 1986). Immunochemical evidence and lectin-binding studies suggested a further correlation on the molecular level among cellulolytic bacteria. The results indicate that such cell surface cellulase-containing structures may be of general consequence to the bacterial interaction with and degradation of cellulose.
...
PMID:Specialized cell surface structures in cellulolytic bacteria. 330 17

We performed an immunoassay evaluation for various analytes on a fully automated random-access analyzer, the Technicon Immuno 1 system from Bayer Corp. This system involves latex agglutination, magnetic separation sandwich, and magnetic separation competitive immunoassay configurations. The evaluated analytes were thyrotropin (TSH), triiodothyronine, thyroxine, free thyroxine, follitropin, lutropin, prolactin, beta subunit of human chorionic gonadotropin, cortisol, ferritin, alpha-fetoprotein, carcinoembryonic antigen, and prostate-specific antigen. We tested the assay precision, linearity, and correlation with comparison methods for these analytes. The functional sensitivity of the TSH assay and the sample-to-sample carryover were also studied. Excellent results were obtained for within-run and between-day precision studies, with most assays showing within-run CVs <4% and between-day CVs <6%. The linearity for all assays was acceptable and the correlation between Immuno 1 assays and comparison methods showed satisfactory results. The functional sensitivity of the TSH assay was estimated at 0.04 mU/L. No sample-to-sample carryover was detected.
...
PMID:Performance evaluation of automated immunoassays on the Technicon Immuno 1 system. 885 56

Ferritin assays were performed using both serum and plasma samples on the Bayer Technicon Immuno 1 Analyser and their ferritin test kit as only data for serum samples are available. After evaluation of the test kit and analyser the results were correlated using the Statistica for Windows programme. It was established that the plasma samples gave consistently lower values than the serum samples. Using the obtained conversion factor of 1.191, plasma as well as serum samples may be used for ferritin determinations.
...
PMID:Ferritin assay performed on the Technicon Immuno 1 analyser using serum and plasma samples. 1235 88

We showed that the content of reticulocyte hemoglobin (CHr) is a reliable measure of iron status with regard to erythrocytopoiesis in chronic dialysis status. The mean CHr level was 32.3 +/- 2.2 pg in dialysis patients and CHr was significantly correlated with the conventional parameters of iron deficiency. We aimed to utilize the measurement of CHr levels to monitor iron status in clinical practice. We measured CHr, iron parameters, and the intrinsic EPO concentration in non-dialysis CRF patients to clarify the alterations in CHr levels that occur as renal anemia progresses. CRF patients who visited our out-patient clinic (n = 189) were included in the study. Iron deficiency was defined by the transferrin saturation and ferritin levels. Conventional red blood cell parameters and CHr levels were measured using an ADVIA120 autoanalyzer (Bayer Medical, USA). The mean CHr value of the non-dialysis patients (creatinine clearance less than 70 ml/min) was 32.7 pg, which did not differ significantly from that of the dialysis patients. Significant correlations were found between CHr and TSAT (r = 0.032, p < 0.0177), unlike the correlation with intrinsic EPO levels. Overall, 11% of the patients were diagnosed as having iron deficiency. There was a positive correlation between CHr and serum creatinine levels. Non-dialysis CRF patients treated with rHuEPO at the dose of 24,000 U/month showed different CHr levels compared with other patients (less than 24,000 U/month). It is possible that rHuEPO treatment in non-dialysis patients affects iron dynamics. In conclusion, CHr is an easily measurable and reliable marker of iron status in non-dialysis CRF patients. Moreover, the CHr level was also sensitive to iron alternations in non-dialysis CRF patients under rHuEPO treatment. Accordingly, if long-acting EPO is available for non-dialysis CRF patients, the CHr value is likely to be indicative of the need for iron supplementation.
...
PMID:[Measuring the content of reticulocyte hemoglobin (CHr) in predialysis chronic renal failure (CRF) patients]. 1450 18

Direct measurement of the reticulocyte hemoglobin content provides useful information for the diagnosis and treatment of iron-deficient states. We have examined direct measurements of reticulocyte and red cell hemoglobin content on the Sysmex XE 2100 (Ret He and RBC He respectively) and the Bayer ADVIA 2120 (CHr and CH respectively) analyzers. Good agreement was found between Ret He and CHr (Y = 1.04X - 1.06; r2= 0.88) and between the RBC He and CH parameters (Y = 0.93X + 1; r2= 0.84 n = 200) in pediatric patients and in normal adults (Ret He and CHr; Y = 1.06X - 0.43; r2= 0.83; n = 126; RBC He and CH; Y = 0.94X + 1; r2= 0.87; n = 126). In 1500 blood samples from patients on chronic dialysis, Ret He was compared with traditional parameters for iron deficiency (serum iron <40 microg/dl, Tsat <20%, ferritin <100 ng/ml, hemoglobin <11 g/dl) for identifying iron-deficient states. Receiver operator characteristic (ROC) curve analysis revealed values of the area under the curve for Ret He of 0.913 (P < 0.0001). With a Ret He cutoff level of 27.2 pg, iron deficiency could be diagnosed with a sensitivity of 93.3%, and a specificity of 83.2%. Ret He is a reliable marker of cellular hemoglobin content and can be used to identify the presence of iron-deficient states.
...
PMID:Reticulocyte hemoglobin equivalent (Ret He) and assessment of iron-deficient states. 1699 19