Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UNIPROT:P01178 (
oxytocin
)
15,767
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Posterior
pituitary hormone secretion and central neural expression of the immediate-early gene product c-Fos was examined in adult ferrets after intravenous administration of CCK octapeptide. Pharmacological doses of CCK (1, 5, 10, or 50 microg/kg) did not induce emesis, but elicited behavioral signs of nausea and dose-related increases in plasma vasopressin (AVP) levels without significant increases in plasma
oxytocin
(OT) levels. CCK activated neuronal c-Fos expression in several brain stem viscerosensory regions, including a dose-related activation of neurons in the dorsal vagal complex (DVC). Activated brain stem neurons included catecholaminergic and glucagon-like peptide-1-positive cells in the DVC and ventrolateral medulla. In the forebrain, activated neurons were prevalent in the paraventricular and supraoptic nuclei of the hypothalamus and also were observed in the central nucleus of the amygdala and bed nucleus of the stria terminalis. Activated hypothalamic neurons included cells that were immunoreactive for AVP, OT, and corticotropin-releasing factor. Comparable patterns of brain stem and forebrain c-Fos activation were observed in ferrets after intraperitoneal injection of lithium chloride (LiCl; 86 mg/kg), a classic emetic agent. However, LiCl activated more neurons in the area postrema and fewer neurons in the nucleus of the solitary tract compared with CCK. Together with results from previous studies in rodents, our findings support the view that nauseogenic treatments activate similar central neural circuits in emetic and nonemetic species, despite differences in treatment-induced emesis and pituitary hormone secretion.
...
PMID:Plasma hormone levels and central c-Fos expression in ferrets after systemic administration of cholecystokinin. 1155 33
In October 1955, stocks of the Second International Standard for
Posterior
Pituitary were running low and the Department of Biological Standards of the National Institute for Medical Research, London, was asked to proceed with the arrangements for an international collaborative assay of material for the Third Standard. A single 142-g batch of posterior-pituitary-lobe powder was obtained and distributed in ampoules, in approximately 30-mg quantities. Samples were sent to 19 laboratories in 10 countries. In all, 185 assays were carried out, 122 for oxytocic activity, 53 for vasopressor activity and 10 for antidiuretic activity.On the basis of the results, which were analysed statistically at the National Institute for Medical Research, it was agreed that the potency of the Third Standard (re-named International Standard for Oxytocic, Vasopressor and Antidiuretic Substances in 1956, in view of the recent synthesis of
oxytocin
and vasopressin) should be expressed as 2.0 International Units per milligram. The International Unit therefore remains unchanged as 0.5 mg of the dry powder.
...
PMID:Third international standard for posterior pituitary; re-named third international standard for oxytocic, vasopressor and antidiuretic substances in 1956. 1358 79
Vasopressin and
oxytocin
are neurohormones of the posterior pituitary lobe released not only into the blood, but also into cerebrospinal fluid (CSF).
Posterior
pituitary lobe has central and peripheral noradrenergic innervation; peripheral origins from superior cervical ganglia (SCG) (Alper et al. 1980; Saavedra 1986). It is known, that sympathetic nervous system is involved in vasopressin (AVP) and
oxytocin
(
OXY
) release from neurohypophysis into the blood (Romeo et al. 1991; Lipinska et al. 1996). The factors which stimulate neurohormones release into the blood do not always cause their release into CSF (Dogterom et al. 1977; Szczepanska-Sadowska et al. 1983). The aim of this study was to elucidate the question whether the stimulation of preganglionic fibers of the SCG could influence the release of AVP and
OXY
into CSF.
...
PMID:Vasopressin and oxytocin release into CSF after sympathetic stimulation in rat. 1862 10
Routine use of a partograph is associated with a reduction in the use of forceps, but is not associated with a reduction in the use of vacuum extraction (Level A). Early artificial rupture of the membranes, associated with
oxytocin
perfusion, does not reduce the number of operative vaginal deliveries (Level A), but does increase the rate of fetal heart rate abnormalities (Level B). Early correction of lack of progress in dilatation by
oxytocin
perfusion can reduce the number of operative vaginal deliveries (Level B). The use of low-concentration epidural infusions of bupivacaine potentiated by morphinomimetics reduces the number of operative interventions compared with larger doses (Level A). Placement of an epidural before 3-cm dilatation does not increase the number of operative vaginal deliveries (Level A).
Posterior
positions of the fetus result in more operative vaginal deliveries (Level B). Manual rotation of the fetus from a posterior position to an anterior position may reduce the number of operative deliveries (Level C). Walking during labour is not associated with a reduction in the number of operative vaginal deliveries (Level A). Continuous support of the parturient by a midwife or partner/family member during labour reduces the number of operative vaginal deliveries (Level A). Under epidural analgesia, delayed pushing (2h after full dilatation) reduces the number of difficult operative vaginal deliveries (Level A). Ultrasound is recommended if there is any clinical doubt about the presentation of the fetus (Level B). The available scientific data are insufficient to contra-indicate attempted midoperative delivery (professional consensus). The duration of the operative intervention is slightly shorter with forceps than with a vacuum extractor (Level C). Nonetheless, the urgency of operative delivery is not a reason to choose one instrument over another (professional consensus). The cup-shaped vacuum extractor seems to be the instrument of choice for operative deliveries of fetuses in a cephalic transverse position, and may also be preferred for fetuses in a posterior position (professional consensus). Vacuum extraction deliveries fail more often than forceps deliveries (Level B). Overall, immediate maternal complications are more common for forceps deliveries than vacuum extraction deliveries (Level B). Compared with forceps, operative vaginal delivery using a vacuum extractor appears to reduce the number of episiotomies (Level B), first- and second-degree perineal lesions, and damage to the anal sphincter (Level B). Among the long-term complications, the rate of urinary incontinence is similar following forceps, vacuum extraction and spontaneous vaginal deliveries (Level B). Anal incontinence is more common following forceps delivery (Level B). Persistent anal incontinence has a similar prevalence regardless of the mode of delivery (caesarean or vaginal, instrumental or non-instrumental), suggesting the involvement of other factors (Level B). Rates of immediate neonatal mortality and morbidity are similar for forceps and vacuum extraction deliveries (Level B). It appears that difficult instrumental delivery may lead to psychological sequelae that may result in a decision not to have more children (Level C). The rates of neonatal convulsions, intracranial haemorrhage and jaundice do not differ between forceps and vacuum extraction deliveries (Levels B and C). Rapid sequence induction with a Sellick manoeuvre (pressure to the cricoid cartilage) and tracheal intubation with a balloon catheter is recommended for any general anaesthesia (Level B). Training must ensure that obstetricians can identify indications and contra-indications, choose the appropriate instrument, use the instruments correctly, and know the principles of quality control applied to operative vaginal delivery. Nowadays, traditional training can be accompanied by simulations. Training should be individualized and extended for some students.
...
PMID:Instrumental delivery: clinical practice guidelines from the French College of Gynaecologists and Obstetricians. 2180 93
<< Previous
1
2