Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UNIPROT:P00790 (PGA)
2,475 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

1. Function of synoviocytes and other cells in the synovium A. Histologic Considerations 1. Electron microscopic studies 2. In vivo and in vitro phagocytosis studies 3. Fluorescent antibody staining B. Culture techniques 1. Problems posed by study of isolated cells 2. Long-term explant cultures 3. Advantages of short-term incubations of synovial fragments 4. Isolation of immunoglobulins C. Non-Immunoglobulin Products of the Synovium 1. Products of normal synovium 2. Alterations induced by rheumatoid arthritis II. The Local Immune response in Rheumatoid Synovitis A. Evidence for Active Immune Stimulation 1. Meditators of cellular immunity in synovial fluid 2. Effect of synovectomy 3. Type and amount of immunoglobulin produced B. Local Commitment of Antibody Response 1. Effect of exogenous immunization 2. Rheumatoid factors. 3. Pepsin agglutinators C. 1. Relative enrichment for IgG-3 subclass 2. Increase in lambda-light chain composition III. Pathogenetic Considerations in Rheumatoid Arthritis A. Comparison of Rheumatoid versus Experimental Immune Synovitis 1. Chronic synovitis as a local immune response. 2. Role of cartilage complexes in substaining chronic synovitis B. Significance of the Restriction in the Immunoglobulin Response in Rheumatoid Arthritis 1. Analogy with other disease states in man 2. Common antigen in RA?
...
PMID:Protein synthesis in rheumatoid synovial tissue. 732 52

Foreign-body reaction to polyglycolide (PGA) implants has been described in man. Many animal experiments have verified the mechanical properties of fixation devices made from PGA, but a significant foreign-body reaction has not been described. We studied the effect of PGA rods in 12 sheep with standardised osteochondral fractures of the medial femoral condyle fixed with uncoloured, self-reinforced PGA rods (Biofix). Radiographs were taken at intervals ranging from two weeks to two years, and the sheep were killed at intervals ranging from six to 24 months. All knees were examined histologically. Eleven of the 12 fractures healed radiologically and histologically. Moderate to severe osteolysis was seen at four to six weeks with maximum changes at 12 weeks in ten animals. Six knees showed fistula-like connections between the implant site and the joint space. Three developed synovitis, one with inflammatory changes involving the whole cartilage and one with destruction of the medial condyle. Although in our study osteochondral fractures fixed with PGA rods healed reliably, there were frequent, significant foreign-body reactions. Caution is needed when considering the use of PGA fixation devices in vulnerable regions such as the knee.
...
PMID:Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: experimental study in sheep. 2690 52

Over a period of 7 years (1987-1994), 24 cases of osteochondritis dissecans of the knee were treated with self-reinforced polyglycolic acid (SR-PGA) and polylactic acid (SR-PLLA) rods. Rods measuring 1.1 mm, 1.5 mm and 2 mm in diameter, and 20-40 mm in length were used in the fixation of the fragment depending on the size of the lesions. There were 23 patients with osteochondritis dessicans in the medial and 1 in the lateral femoral condyle. The average age of the patients was 25 years (range: 16-48). Follow-up was for 3.3 years (range: 1-7.6). There were 6 lesions in situ, 3 early separations, 11 were partially detached, and there were 4 loose bodies. SR-PGA rods were used in 12 patients, SR-PLLA rods in 11 patients, and both SR-PGA and SR-PLLA rods in 1 patient. The rod in each case was inserted subchondrally and in 9 cases arthroscopically, using a special instrument. In our study, the clinical result was excellent in 13 patients, good in 6, fair in 1 and poor in 4. On radiological assessment the fragment had healed in 19 cases. Synovitis occurred in 1 patient in the SR-PGA group (1/13): the effusion continued for 6 months postoperatively but, after treatment by needle aspiration, there were no symptoms at follow-up 4.2 years later. We conclude that SR-PGA and SR-PLLA rods can be used intra-articularly for the adequate fixation of osteochondritis dissecans.
...
PMID:Osteochondritis dissecans of the knee fixed with biodegradable self-reinforced polyglycolide and polylactide rods in 24 patients. 949 41

The causes of a clinical tissue response to self-reinforced polyglycolide (SR-PGA) and self-reinforced polylactide (SR-PLLA) implants were studied in the first 2500 polymeric fixations. The incidence was 8.0% in fixations with implants made of SR-PGA (n = 1879) and 0% in SR-PLLA fixations (n = 621). A small number of fixations per site seemed to increase the incidence of a tissue response. In diagnoses involving over 50 fixations, except for ankle fractures, the incidence was 4.2%. The site of fixation influenced the incidence; the lowest incidence was seen for radial head fracture fixation (1.1%). The aromatic dye which has not been used since 1988 in the SR-PGA implant increased the response. A large total implant volume and a large number of implants increased the incidence of a tissue response. In the knee (n = 131), the incidence of a clinical tissue response was 4.3%, with four fluid accumulations and one synovitis of the knee after fixation with SR-PGA implants.
...
PMID:Causes of the clinical tissue response to polyglycolide and polylactide implants with an emphasis on the knee. 1140 55