Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UNIPROT:P00750 (PLA)
16,800 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

The antigenic and allergenic properties of phospholipase A2 (PLA2) and whole bee venom were compared by measuring the IgG and IgE antibody responses in animals and man. Precipitating antibodies raised in rabbits and reaginic and other antibodies raised in mice reacted about equally with both bee venom and PLA. The majority of human sera containing bee venom-specific IgE also contained PLA-specific IgE, although in somewhat lower titers. Similarly, most human sera with significant amounts of total antibodies reacting with bee venom also had antibodies reacting with PLA. Histamine and SRS-a release from leukocytes of sensitive patients followed challenge with whole bee venom and PLA in the majority of instances. However, mediator release from several patients' cells was obtained with bee venom only. These studies suggest that although PLA is a major allergen and antigen in bee venom, significant exceptions in patients' reactivity may limit its potential diagnostic and therapeutic usefulness.
...
PMID:Studies of the antigenicity and allergenicity of phospholipase A2 of bee venom. 5 45

This study compared the osteogenic potential and tissue compatibility of biodegradable copolymers--PLA/PGA--and a biodegradable ceramic--Ca3(PO4)2. These compounds were placed in experimentally created defects in rat tibias, both in combination and singly, and evaluated at 14, 28, and 42 days. The ceramic served as a format to result in uniform osteogenesis throughout the defect. The copolymer implants resulted in a more gradual bone formation, progressing slowly from the would peripheries. The ceramic and copolymer combination behaved little differently from the copolymer alone. All experimental materials were extremely tissue tolerant, with minimal inflammation and no foreign-body reactions.
...
PMID:Evaluation and comparisons of biodegradable substances as osteogenic agents. 26 77

The effect on lung compliance of changes in intra- and extravascular volumes has been studied. Such changes were induced by inflation and deflation of a balloon placed in the left atrium in open-chest cats. Blood constituents were labeled with isotopes, and tissue water content was found from the wet/dry labeled with isotopes, and tissue water content was found from the wet/dry weight ratio. When left atrial pressure (PLA) was elevated to a value not exceeding 32 mmHg (4.256 kPa), there was only a minute increase in tissue water volume, and we observed a reversible reduction in lung compliance related to the rise in lung blood volume. At higher PLA, a rapid rise occurred in extravascular fluid volume, with evidence of alveolar flooding. Earlier experiemtns have shown that, in isolated perfused lung, a situation of slow, steady increase in interstitial fluid can be created. This does not seem to be the case with lungs in situ: once the lymphatic drainage is unable to cope with transvascular fluid flow, an unstable situation is created. This rapidly leads to alveolar flooding and a fall in compliance in addition to that caused by a rise in blood volume. From our fluid and pressure determinations, we calculated a filtration coefficient (Kf) of 0.45 ml/100 g wet lung X cmH2O X h. This is within the range reported for sheep lungs. Observation of dynamic lung compliance cannot be used for detection of interstitial fluid accumulation. It appears, however, that in contrast to isolated lungs, this phase of edema-formation rapidly leads to alveolar flooding.
...
PMID:Hydrostatic pulmonary edema in the cat. Effects on pulmonary blood and water volumes and on lung compliance. 33 53

In 34 patients with mitral stenosis or combined mitral valve disease class II, III or IV (NYHA), the mitral valve closure index (MVCI, Shiu et al. 1977), based on the rate of diastolic apposition of the anterior and posterior mitral leaflet echos, and the diastolic closure rate (EF-slope) were determined and compared with hemodynamic data such as mean left atrial pressure (PLA), mean diastolic pressure gradient across the stenotic valve (DP) and mitral valve orifice area (Q), calculated by the Gorlin formula. MVCI and EF-slope correlated more favorably with DP (MVCIr = -0.71, EF-sloper = -0.53) than with Q and PLA. The results were not different in patients with sinus rhythm or atrial fibrillation. Using MVCI or EF-slope thie discrimination between severe and moderate or between moderate and light mitral stenosis was uncertain. Nevertheless, MVCI below 30 was associated with light, above 50 with severe mitral stenosis. In spite of the relationship between MVCI or EF-slope and the severity of mitral stenosis, in the individual case an exact quantification of mitral stenosis is not possible due to the great variability of echocardiographic data. For the assessment of the severity of mitral stenosis the mitral valve closure index is not superior to the EF-slope.
...
PMID:[Echocardiographic determination of the severity of mitral stenosis by the mitral valve closure index (author's transl)]. 50 63

The purpose of the present work was to measure prostaglandin (PG)-like activity in arterial blood during acute pulmonary hypertension. Anesthetized cats with the chest opened and given positive pressure ventilation were used. A balloon in the left atrium was inflated to elevate hydrostatic vascular pressure in the lungs. Blood was pumped (10 ml/min) from a carotid artery to superfuse 3 smooth muscle tissues: rat stomach strip, rat colon and chick rectum: the blood was then returned to the jugular vein by gravity. The assay tissues were pretreated with antagonists against catecholamines, histamine, serotonin and acetylcholine during the experiments. They were sensitive to calibrating doses of 2 ng/ml of PGF2 alpha and 1 ng/ml of PGE2. 18 periods with elevated left atrial pressure (P LA) (21--49 mmHg), lasting 2--26 min, were applied in 9 cats. This manoevre usually also caused systemic hypotension. 14 of these PLA elevations were accompanied by increased arterial PG-like activity, which rapidly subsided when the pressure was released or when indomethacin (2 mg/kg, n = 4) was given i.v. In 3 additional experiments it was found that pulmonary degradation of PGs was unaffected during P LA elevation. I.v. infusion of angiotensin II contracted the tissues in a pattern different from that caused by pressure elevations and the PG calibrations, and these contractions were not affected by indomethacin. This indicates that the assay tissue contractions cannot be caused by angiotensin II which alone does not increase PG-like activity in arterial blood. Consequently, acute pulmonary vascular hypertension appears to stimulate PG synthesis and release in lungs of intact cats.
...
PMID:Release of prostaglandin-like substances during elevations of left atrial pressure in the cat. 52 82

In 30 patients with congenital or acquired heart disease the haemodynamic effects of diazepam (Valium) 0.3 mg/kg were investigated during surgical procedures under neuroleptanalgesia. The following parameters were measured or calculated: Heart rate (HR), arterial pressure (-Part, Psyst, Pdiast), pulmonary artery pressure (-PAP), right (-PRA) and left atrial pressure (-PLA), left ventricular pressure (PLV), left ventricular enddiastolic pressure (PLVED), left ventricular peak dp/dt (dp/dtmax), cardiac output (CO), cardiac index (CI), stroke volume (SV), stroke index (SI), total systemic resistance (TSR), total pulmonary resistance (TPR), work index of the right (RVWI) and left ventricle (LVWI). In comparison with a control group (n = 36) diazepam caused a decrease in arterial pressure cardiac index, stroke index, right and left atrial pressure and dp/dtmax. This, however, was mainly attributable to vasodilatation and not to a negative inotropic effect, which is of only minor importance with diazepam. These haemodynamic changes resulted in a reduction in myocardial oxygen consumption. Diazepam is a valuable drug in neuroleptanalgesia, when an increase in blood pressure can not be controlled by fentanyl or droperidol.
...
PMID:[Diazepam (valium). Changes in haemodynamics, myocardial oxygen consumption and vascular tone (author's transl)]. 69 81

Six cases of Glanzmann's thrombasthenia were studied using a platelet indirect radioactive Coombs (PIRC). In serum of two among six patients, an antibody was found, which reacted positively with all platelets except those of thrombasthenic patients. Such "anti-public" antibody which shortens the life of transfused platelets is a very serious complication of Glanzmann's thrombasthenia. Attempts to define the PLA group of the six Glanzmann patients, with human allo antisera recognizing PLA1 antigen, gave negative results. Three hypothesis were discussed: (1) Interference in the test of the aggregation defect of thrombasthenic platelets. However, anti-HLA antibodies were normally fixed in the PIRC test. (2) PLA2 gene and Glanzmann gene have a strong gametic association and all Glanzmann's patients are PLA1 negative. (3) Glanzmann gene is coding for the PLA gene substrate. In such case, thrombasthenic patients might be genetically PLA1 positive and phenotypically PLA1 negative. Moreover they would also be PLA2 negative, this could not be tested due to the lack of anti-PLA2 antiserum.
...
PMID:[Glanzmann thrombasthenia, PLA1 antigen and anti-Glanzmann antibody]. 75 43

In eight dogs anesthetized with chloralose and urethan, Valsalva-like maneuvers (VLMs) were performed and central blood volume (CBV) measured following incremental volume loading with blood-dextran. Changes in blood pressure during VLM were characterized by 1) maximum change in systolic pressure (deltaPmax) during VLM; 2) change in systolic pressure during the first five beats of VLM (deltaP1-5); and 3) the change in pulse pressure during the first 10 beats of VLM. In three dogs, we also measured changes in right and left atrial pressure (PRA, PLA), esophageal pressure (PE), and pulmonary and aortic blood flow. We found that volume loading produced a continuous spectrum of hemodynamic changes culminating in the "square-wave" response. deltaPmax and deltaP1-5 correlated with changes in CBV. Changes in hemodynamic responses were produced by increases in CBV, and by incomplete prevention of systemic venous return during VLM. The mechanism of the square-wave response may be a combination of both these effects, with the latter the more significant of the two.
...
PMID:Pressure and flow changes during Valsalva-like maneuvers in dogs following volume infusion. 87 39

This study determined the difference in rate of degradation between pure polymers of lactic acid (pla), glycolic acid (PGA), and various ratios of copolymers of these two substances. Fast-cured and slow-cured polyglycolide was compared with copolymers of glycolide/lactide intermixed in ratios of 75:25, 50:50, and 25:75, as well as pure polylactide. A total of 420 rats were implanted with carbon-14 and tritium-labeled polymers in bone and soft tissue. At intervals of 1, 2, 3, 5, 7, 9, and 11 months, groups of five animals with the implants in bone and five with the implants in the abdominal wall were sacrificed. The implant area as well as tissue from the liver, spleen, kidney, lung and some muscle tissue was analyzed for radioactivity along with the urine and feces collected throughout the experiment. Half-lives of the different polymers and copolymers were calculated from the radioactivity present in the implant area for each time interval. Half-life of the polymers and copolymers decreased from 5 months for 100% PGA to 1 week with 50:50 PGA:PLA copolymer and rapidly increased to 6.1 months for 100% PLA. Fast-cured PGA had a half-life in tissue of 0.85 months. No difference in rate of degradation was seen in soft tissue or bone. No significant radioactivity was detected in urine, feces, or tissue samples. From this study, it is concluded that control of degradation rate of the implant could best be attained by varying the composition of PLA and PGA between 75% and 100% PLA along with a corresponding 25% to 0% PGA. This would provide a half-life range of the implant of from 2 weeks to 6 months.
...
PMID:Degradation rates of oral resorbable implants (polylactates and polyglycolates): rate modification with changes in PLA/PGA copolymer ratios. 89 90

A platelet indirect radio-active Coombs test has been described. The technique for purification and labelling the antiglobulin has been precised. This test allows the typing of platelets in the PLA system and the study of sera from mothers of thrombocytopenic child. As examples, four families of neonatal thrombocytopenia are reported, with PLA1 negative mother. In the serum of three of these mothers, we could demonstrate anti-PLA antibodies in spite of a negative platelet complement fixation. This test has many advantages compared to other tests such as platelet complement fixation, assay for blocking antibodies or antiglobulin consumption: it gives objective and quantitative results and is highly reproducible, anticomplementary serum may be tested. It has enabled us to select PLA1 negative donors for exsanguino-transfusions of thrombocytopenic children born from PLA1 negative mothers.
...
PMID:[Typing and detection of antibodies in the PLA system (platelet). Application to the study of neonatal thrombopenia by feto-maternal PLA allo-immunisation]. 100 52


1 2 3 4 5 6 7 8 9 10 Next >>