Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UNIPROT:P00492 (
hypoxanthine-guanine phosphoribosyltransferase
)
2,385
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
The incorporation of [15N]delta-aminolaevulinic acid and [15N glycine into haemoglobin haem and early labelled bilirubin was measured in subjects with various haematological disorders. The clearance of [14C bilirubin was used to measure bilirubin production rate, and the magnitude of the various sources of bilirubin production and the percentage ineffective erythropoiesis were calculated. Ineffective erythropoiesis was found to be a major factor in the production of the anaemia in patients with the following disorders: megaloblastic anaemia associated with the
Lesch-Nyhan syndrome
, thalassaemia intermedia, sideroblastic anaemia, and the anaemia of chronic disorders. In three patients with iron-deficiency anaemia ineffective erythropoiesis was increased, but was of minor importance in the production of the anaemia, while in two patients with aplastic anaemia and one with macrocytosis of
alcoholism
there was no increase in ineffective erythropoiesis.
...
PMID:Quantitation of ineffective erythropoiesis from the incorporation of [15N] delta-aminolaevulinic acid and [15N] glycin into early labelled bilirubin. II. Anaemic patients. 95 67
The aim of the present study is to establish a highly sensitive method for the determination of uric acid (UA) in human saliva. The monitoring of UA levels in less invasive biological samples such as saliva is suggested for the diagnosis and therapy of gout, hyperuricemia, and the
Lesch-Nyhan syndrome
, and for detecting such conditions as
alcohol dependence
, obesity, diabetes, high cholesterol, high blood pressure, kidney disease, and heart disease. Reversed-phase high-performance liquid chromatography with electrochemical detection (HPLC-ED) was employed for the determination of UA obtained by solid-phase extraction from saliva. To quantify UA, we compared the ED efficiencies of an amperometric ED (Ampero-ED) with a single electrode and a coulometric ED (Coulo-ED) with a multiple electrode array. The results showed that the detection limits (S/N=3) were 3 nM for Ampero-ED and 6 nM for Coulo-ED, and the linearity of the calibration curves of 60-6000 nM had correlation coefficients exceeding 0.999. In addition, the total analytical time was 10 min. In the sample preparation of UA in saliva, an Oasis MAX solid-phase cartridge was used. The recoveries of UA spiked at 0.6 and 3 microM in saliva were above 95% with a relative standard deviation (RSD) of less than 15%. Therefore, the present method may be used in the routine and diagnostic determination of UA in human saliva.
...
PMID:Determination of uric acid in human saliva by high-performance liquid chromatography with amperometric electrochemical detection. 1253 38