Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UNIPROT:A7KAX9 (
grit
)
1,275
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Two-choice tests were conducted to examine the effect of surface roughness on the resting preference of bed bugs, Cimex lectularius L., on copper, basswood, and acrylic materials. The influence of pyrethroid formulation applications on resting preferences was also evaluated. Bed bugs were given the choice of resting between two sanded halves of each material tested. One half was sanded with a P60
grit
sandpaper and the other with a less rough
P600
grit
sandpaper. A significantly higher proportion of bed bugs chose to rest on the rougher P60
grit
sanded half of all materials tested. Pyrethroid applications were made to either the P60
grit
half or both halves of acrylic arenas and resting preferences were again assessed. Behavioral responses of bed bugs to pyrethroid formulation applications varied depending on the bed bug strain used and the formulation applied. Bed bugs would still rest on the P60
grit
half when Suspend SC formulation (0.06% deltamethrin) was applied; however, an avoidance response was observed from a bed bug strain susceptible to D-Force aerosol formulations (0.06% deltamethrin). The avoidance behavior is likely attributed to one, more than one, or even an interaction of multiple spray constituents and not the active ingredient.
...
PMID:The Influence of Roughness and Pyrethroid Formulations on Bed Bug (Cimex lectularius L.) Resting Preferences. 2646 96
In this study the influence of the surface roughness on the transmission capacities of D-shaped plastic optical fibers (POFs) and sensors performance was investigated. Five D-shaped POF sensors were produced and characterized for refractive index sensing between 1.33 and 1.41. The sensors were characterized using a low-cost optical sensing system based on the variation of the transmitted light though the POF with refractive index changes (RI). Higher surface roughness increases the scattering losses through the POF and influences the sensors' performance; therefore, a balance must be attained. Generally, the best performance was achieved when the sensing region was polished with
P600
sandpaper as a final polishing step. Polishing with sandpapers of lower
grit
size resulted in lower scattering, higher linearity of the sensor response and generally lower performance for RI sensing. A sensor resolution of 10
-3
-10
-4
RIU, dependent on the value of the external refractive index, was obtained through simple and low-cost manufacturing procedures. The obtained results show the importance of surface roughness in the development of POF sensors which can be used in several applications, such as for water quality assessment.
...
PMID:D-Shaped POF Sensors for Refractive Index Sensing-The Importance of Surface Roughness. 3115 Dec 17