Query: UNIPROT:A7KAX9 (
grit
)
1,275
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Surface topography plays a critical role in the interaction of dental implants with adjacent tissues. It has been hypothesized that an increase in surface roughness will result in an increase in calcium and phosphorus deposition after immersion in a simulated physiological solution and will increase protein production and calcium uptake by osteoblast-like cells. With the use of a profilometer, titanium samples ground with 600
grit
silicon carbide paper were observed to have an average roughness (Ra) value of 0.28 +/- 0.03 micron, whereas titanium samples polished with 0.3 micron Al2O3 exhibited a Ra value of 0.11 +/- 0.01 micron. X-ray photoelectron spectroscopy analyses indicated the presence of calcium, phosphorus, sodium, and
chlorine
on both surface conditions after immersion in a protein-free physiologic solution. No significant difference in calcium and phosphorus concentrations were observed between the 600
grit
or Al2O3 polished titanium samples after immersion in solution. The Ca/P ratio for both 600
grit
and Al2O3 polished titanium was in the range of 0.8 to 1.1 after 12 days in solution. The percent protein retained by the rat bone marrow cell layer on both the Al2O3 polished and 600
grit
titanium surfaces increased dramatically during the initial 3 days of the study. The 45Ca assays revealed no significant difference in cellular calcification on Al2O3 polished and 600
grit
titanium surfaces. For both the Al2O3 polished and 600
grit
surfaces, a sharp increase in 45Ca incorporation was observed after 9 days incubation.
...
PMID:Effect of surface topography of titanium on surface chemistry and cellular response. 908 79
This study examined the effects of different treatments (polished, electropolished, and
grit
-blasted) on the surface morphology and chemistry of commercially pure titanium and titanium-6% aluminum-4% vanadium. The structure and composition of the surfaces were evaluated using scanning electron microscopy, atomic force microscopy, energy dispersive spectroscopy, Auger microprobe analysis, and x-ray photoelectron spectroscopy. Surface roughness values at large scales were nearly identical for
grit
-blasted and electropolished samples, while at smaller scales, electropolished and polished samples had nearly identical quantitative roughness values. The surface oxide compositions were found to be primarily titanium dioxide on both materials for all surface treatments. No vanadium was seen with either x-ray photoelectron spectroscopy or Auger microprobe analysis for the alloy, indicating a possible surface depletion. Calcium was present on the
grit
-blasted samples, and calcium and
chlorine
were detected on the electropolished samples.
...
PMID:Surface characterization of titanium-based implant materials. 1087