Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C1835664 (
TOC
)
2,763
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
In this paper, the performance of a photoassisted electrolysis process, for the degradation of organic pollutants, is investigated. Results obtained in this work have shown that the thermally prepared anode of titanium, coated with 70TiO2/30RuO2, exhibits photoactivity and may be used for the treatment of effluents. A synthetic phenol aqueous solution and a real paper mill industry effluent were treated. Kinetic analysis showed a synergetic effect of electrolysis and photocatalysis and degradation rates are an order of magnitude greater than the sum of the results reached by using both processes individually. Using a 125 W mercury bulb and 20 mA cm-2, the phenol concentration decayed 85% in 90 min and 70% reduction of
TOC
was obtained. In the application of the treatment process for the degradation of the E1 bleach Kraft mill effluent, total phenols were practically eliminated in a short period of processing time, and color, usually resistant to biological treatment, was reduced to 10% from its initial value measured in terms of absorbance. Reductions of
AOX
, COD, and BOD by 25%, 30%, and 35%, respectively, were also observed.
...
PMID:Photoassisted electrochemical degradation of organic pollutants on a DSA type oxide electrode: process test for a phenol synthetic solution and its application for the E1 bleach Kraft mill effluent. 1145 21
In this article, the wastewater treatment by UV oxidation with and without preceding desalination is compared. The influence of different chloride concentrations on the
TOC
degradation and
AOX
concentration is analyzed. Nanofiltration membrane dialysis is used to separate the chloride ions from wastewater. It is demonstrated that a reduction of the chloride concentration leads to a faster
TOC
degradation compared to the treatment of non-desalinated wastewater. Furthermore, the additional formation of
AOX
during the process could be avoided in effect leading to a significant degradation of native
AOX
.
...
PMID:Improved AOX degradation in UV oxidative waste water treatment by dialysis with nanofiltration membrane. 1148 22
Electrochemical oxidation of resorcinol for wastewater treatment in the presence of chloride was investigated. Titanium Substrate Insoluble Anode (TSIA) coated with TiO2-RuO2-IrO2 was used as an anode and graphite carbon sheet was used as a cathode. The extent of resorcinol electrochemical oxidation was determined in terms of COD removal. The Box-Behnken second order composite design was used to study the effect of operating parameters such as initial pH, chloride concentration, initial concentration of resorcinol and charge input. The experimental values were in good correlation with predicted values, and the correlation coefficient was found to be good. The effect of current density on resorcinol oxidation, the
AOX
level during the electrochemical treatment and
TOC
removal were also studied for selected conditions. It has been observed that the extended electrolysis brings down the
AOX
concentration to lower levels. The maximum current efficiency was observed at higher resorcinol concentration, higher chloride concentration and increasing current density.
...
PMID:Electrochemical oxidation of resorcinol for wastewater treatment using Ti/TiO2-RuO2-IrO2 electrode. 1175 10
A Penicillium camemberti strain isolated in our laboratory has been studied for its ability to degrade chlorinated pulping wastes, presumably containing a variety of chlorinated polyphenols. In batch tests, the highest removals (76%
AOX
, 61% color and 65%
TOC
) were obtained with 0.2 g/l feed acetate concentration. The tendency of the fungus to dechlorinate bleachery effluents better under non-shaking conditions and to attach onto surfaces suggested the use of immobilized cells rather than freely suspended ones in further exploitation of the process. An upflow glass wool packed column reactor established with this fungus could be operated for nearly two years in the laboratory. At best around 70%
AOX
could be removed from chlorinated pulping wastes in 7.3 h of contact with no aeration and with a minimal amount of carbon supplement (0.2 g/l). Finally, an asymptotic mathematical formula for determining Michaelis-Menten kinetic rates has been derived. The kinetic rates K(m) (the Michaelis constant or saturation constant for the substrate) and V(m) (the product of maximum rate for the enzymatic reaction and biomass concentration) were then calculated as 126.386 mg/l and 2.83017 mg/lh, respectively.
...
PMID:Upflow column reactor design for dechlorination of chlorinated pulping wastes by Penicillium camemberti. 1525 Dec 23
The toxicity and chemical quality of surface water and sediment in the River Traun in Austria were studied because of recurrent fish mortality in some alpine rivers over the last few years. The analyses were carried out on samples collected during winter and summer upstream and downstream of two municipal wastewater treatment plants (WWTPs) and on effluents taken at the points of discharge of these two plants. Toxicity tests were performed on 20 samples of surface water, effluent, and sediment pore water. The test battery was composed of microbiotests with protozoans (Protoxkit F), microalgae (Algaltoxkit F), crustaceans (Daphtoxkit F magna and Thamnotoxkit F), and a higher plant (seed germination and root elongation assay on cress). Direct contact tests were performed on whole sediment with crustaceans (Ostracodtoxkit F). The physical-chemical characteristics of the surface water, effluent, and sediment pore water samples analyzed were conductivity, total hardness, pH, O(2), BOD(5),
TOC
, DOC,
AOX
, NH(4), NH(3), NO(2), PO(4)--P, Cd, Pb, Cu, and Zn. The toxicity data were expressed as percentage mortality or percentage inhibition, depending on the effect criterion of the respective assay. None of the water samples collected upstream and downstream of the WWTPs showed any significant (short-term) toxicity in either winter or in summer, but the effluents of the first municipal wastewater treatment plant were toxic to some of the test biota. All the sediment pore water samples induced serious inhibition of root growth of cress, and several pore waters were toxic to other test biota as well, particularly at the outlets of the WWTPs. The toxic character of some sediments was confirmed by direct contact tests with the ostracod crustacean. The chemical analyses did not reveal particularly high concentrations of any chemical that is very toxic. As a result no direct causal relationship could be established between the detected toxic effects and the chemical composition of the surface waters or sediment pore waters. The outcome of this preliminary study again highlights the need to complement chemical analyses with toxicity tests to determine the toxic hazard to aquatic environments that may be threatened by contamination. Furthermore, the investigations also confirmed the need to apply a battery of tests for an ecologically meaningful evaluation of the hazards of waters, sediments, and wastewaters. Finally, the results of the 360 bioassays performed show that culture-independent microbiotests are practical and reliable tools for low-cost toxicity monitoring of aquatic environments.
...
PMID:Toxicity assessment of wastewaters, river waters, and sediments in Austria using cost-effective microbiotests. 1526
This paper presents the results of the treatment of phenolic compounds containing wastewater generated from phenol-formaldehyde resin manufacturing, oil refinery and bulk drug manufacturing industries by electrochemical method. Experiments were conducted at a fixed current density of 5.4 A/dm2 using Ti/TiO2-RuO2-IrO2 electrode and an undivided reactor. During the various stages of electrolysis, parameters such as COD and
TOC
concentrations were determined in order to know the feasibility of electrochemical treatment. Adsorbable organic halogens (AOX) were detected at high concentrations during the electrolytic treatment of the effluents. However, it was observed that increasing the electrolysis time bring down the
AOX
concentration to lower levels. Energy consumption and current efficiency during the electrolysis were calculated and presented. The present study proves the effectiveness of electrochemical treatment for highly concentrated bio-refractory organic pollutants present in the industrial wastewater.
...
PMID:Electrochemical treatment of industrial wastewater. 1536 21
In this study, the effects of chloride ion concentration and pH on UV oxidation treatment were examined. Acetone and sodium dodecyl sulfate (ABS) were used as organic substances. The treatment efficiencies of these chemicals by UV/H(2)O(2) oxidation using a laboratory scale UV-free surface reactor (UV-FSR) with or without Cl(-) addition at different pH values was compared. Results of this study indicated that Cl(-) concentration and the chemical structure of the substances are more decisive than pH in the oxidation process. There was no
AOX
at the start of the experiments but as a result of oxidation a de novo synthesis of
AOX
was observed, and these
AOX
(de novo) compounds were destroyed during the treatment. Treatment was followed by
TOC
and
AOX
measurements. Approximately 98% and 95%
TOC
removal efficiencies were obtained for the treatment of acetone and ABS containing wastewaters, respectively.
...
PMID:Influence of chloride concentration on the formation of AOX in UV oxidative system. 1703 91
The hot acid hydrolysis followed by chlorine dioxide (A/D*) and hot chlorine dioxide (D*) technologies have proven very useful for bleaching of eucalyptus kraft pulp. Although the characteristics and biodegradability of effluents from conventional chlorine dioxide bleaching are well known, such information is not yet available for effluents derived from hot acid hydrolysis and hot chorine dioxide bleaching. This study discusses the characteristics and biodegradability of such effluents. Combined whole effluents from the complete sequences DEpD, D*EpD, A/D*EpD and ADEpD, and from the pre-bleaching sequences DEp, D*Ep, A/D*Ep and ADEp were characterized by quantifying their colour,
AOX
and organic load (BOD, COD,
TOC
). These effluents were also evaluated for their treatability by simulation of an activated sludge system. It was concluded that treatment in the laboratory sequencing batch reactor was efficient for removal of COD, BOD and
TOC
of all effluents. However, colour increased after biological treatment, with the greatest increase found for the effluent produced using the AD technology. Biological treatment was less efficient at removing
AOX
of effluents from the sequences with D*, A/D* and AD as the first stages, when compared to the reference D stage; there was evidence of the lower treatability of these organochlorine compounds from these sequences.
...
PMID:Effect of hot acid hydrolysis and hot chlorine dioxide stage on bleaching effluent biodegradability. 1748 33
Drinking water is often produced from surface water by riverbank filtration (RBF) or artificial groundwater recharge (AGR). In this study, an AGR system was exemplarily investigated and results were compared with those of RBF systems, in which the effects of redox milieu, temperature and surface water discharge on the cleaning efficiency were evaluated. Besides bulk parameters such as DOC (dissolved organic carbon), organic trace pollutants including iodinated X-ray contrast media, personal care products, complexing agents, and pharmaceuticals were investigated. At all studied sites, levels of
TOC
(total organic carbon), DOC,
AOX
(adsorbable organic halides), SAC (spectral absorption coefficient at 254 nm), and turbidity were reduced significantly. DOC removal was stimulated at higher groundwater temperatures during AGR. Several substances were generally easily removable during both AGR and RBF, regardless of the site, season, discharge or redox regime. For some more refractory substances, however, removal efficiency turned out to be significantly influenced by redox conditions.
...
PMID:Effects of boundary conditions on the cleaning efficiency of riverbank filtration and artificial groundwater recharge systems regarding bulk parameters and trace pollutants. 2267 10
Pulp paper mill effluent has high pollution load due to presence of lignin and its derivatives as major colouring and polluting constituents. In this study, two lignin degrading bacteria IITRL1 and IITRSU7 were isolated and identified as Citrobacter freundii (FJ581026) and Citrobacter sp. (FJ581023), respectively. In degradation study by axenic and mixed culture, mixed bacterial culture was found more effective compared to axenic culture as it decolourized 85 and 62% of synthetic and kraft lignin whereas in axenic conditions, bacterium IITRL1 and IITRSU7 decolourized 61 and 64% synthetic and 49 and 54% kraft lignin, respectively. Further, the mixed bacterial culture also showed the removal of 71, 58%
TOC
; 78, 53%
AOX
; 70, 58% COD and 74, 58% lignin from synthetic and kraft lignin, respectively. The ligninolytic enzyme was characterized as manganese peroxidase by SDS-PAGE yielding a single band of 43 KDa. The HPLC analysis of degraded samples showed reduction as well as shifting of peaks compared to control indicating the degradation as well as transformation of compounds. Further, in GC-MS analysis of synthetic and kraft lignin degraded samples, hexadecanoic acid was found as recalcitrant compounds while 2,4,6-trichloro-phenol, 2,3,4,5-tetrachloro-phenol and pentachloro-phenol were detected as new metabolites.
...
PMID:Bacterial degradation of synthetic and kraft lignin by axenic and mixed culture and their metabolic products. 2455 27
1
2
Next >>