Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C1658953 (tumor vasculature)
2,390 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

This study evaluates the histopathological changes that follow insonation of a neoplasm with physiotherapy ultrasound. In 27 mice (C3HV/HeN strain), a subcutaneous melanoma (K1735(22)) was insonated with continuous physiotherapy ultrasound (1 MHz; spatial-average-temporal-average = 2.3 W cm(-2)). Analyses of contrast enhanced (0.1 mL Optison) power Doppler observations showed that insonation significantly (p < 0.05) increased the avascular area in the neoplasm. The predominant acute effect of insonating the neoplasm was an apparently irreparable dilation of the tumor capillaries with associated intercellular oedema; other immediate effects were haemorrage and increased intercellular fluid. Liquefactive necrosis of neoplastic cells was a delayed effect. There was a high correlation (R2 = 0.91) between the percent area affected on histologic examination and the percent increase in avascularity of the neoplasm in the Doppler study. In conclusion, physiotherapy ultrasound produced histologic changes in the tumor vasculature that were consistent with observations made by contrast enhanced power Doppler ultrasound.
...
PMID:Histopathological observations of the antivascular effects of physiotherapy ultrasound on a murine neoplasm. 1653 Jan 5

Many factors affect the sensitivity and reliability of tumor vasculature assessment at the small doses of contrast agent necessary for imaging mice. In this study we investigate the dose-response relationship of ultrasound contrast agent for a minimal exposure power Doppler technique (minexPD) in a murine melanoma model. K1735 murine melanomas grown in 25 C3H/HeN mice were imaged by power Doppler ultrasound using different doses of contrast agents, Optison(R) and Definity(R). Six mice were treated with an antivascular agent, combretastatin A4-phosphate (CA4P), and imaged before and after treatment. The color-weighted fractional area (CWFA) of the peak-enhanced image was measured to assess tumor perfusion on a relative scale of 0 to 100. CWFA increased logarithmically with dose (R(2)=0.97). Treatment with CA4P resulted in pronounced reduction in tumor perfusion 2 h after contrast injection, but perfusion recovered in the tumor periphery after 2 days. CWFA was significantly different between pre- and post-treatment for all doses at 2 h and 2 days (p < 0.05, respectively). There was no significant difference detectable between the two contrast agents, Optison(R) and Definity(R) (p = 0.46). In vivo tumor enhancement in mice increases as logarithmic function with dose. Although the extent of enhancement is dose dependent, the difference between pre- and post-therapy enhancement is relatively unchanged and uniform at varying doses. The two contrast agents tested in this study performed equally well. These results suggest that quantitative contrast-enhanced power Doppler imaging is an effective method for monitoring therapy response of tumors in mice.
...
PMID:Dose-response relationship of ultrasound contrast agent in an in vivo murine melanoma model. 1808 51