Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0851184 (thinning)
11,252 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Parkinson's disease (PD) patients frequently develop cognitive impairment. There is a need for brief clinical assessments identifying PD patients at high risk of progressing to dementia. In this study, we look into predicting dementia in PD and underlying structural and functional correlates to cognitive decline in PD. We included 175 patients with PD, 30 with PD dementia, 51 neurologically healthy controls and 121 patients with Alzheimer's disease (AD) from Skane University Hospital, BIOFINDER cohorts. All underwent cognitive tests, including MMSE, 10-word list delayed recall (ADAS-cog), A Quick Test of cognitive speed (AQT), Letter S fluency, Clock Drawing Test (CDT) and pentagon copying. In non-demented patients with PD, abnormal AQT and CDT results predicted an increased risk of subsequent development of dementia (hazard ratio 2.2 for both). When comparing the cognitive profile between PD and AD, decreased performance on AQT, which measures attention and processing speed, was more typical in PD. Lastly, we investigated the underlying structural and functional correlates for the PD-specific test AQT with magnetic resonance imaging. In PD patients, decreased performance on AQT was associated with i) cortical thinning in temporoparietal regions, ii) changes in diffusion MRI, especially in the cingulum tract, and iii) decreased functional connectivity in posterior brain networks.
...
PMID:A quick test of cognitive speed can predict development of dementia in Parkinson's disease. 3165 72

Advanced Keratoconus and ectatic corneal diseases may lead to corneal thinning and irregular astigmatism. The optical distortion caused by these pathologies may result in poor visibility for the surgeon during phacoemulsification. Thus, the risk of complication would be increased intraoperatively (capsular rupture, vitreous loss). The aim of this case series was to use a modified customized Rigid Gas Permeable (RGP) contact lens to improve visualization during all the stages of phacoemulsification in irregular corneas and to avoid open sky technique for cataract removal during penetrating keratoplasty (PK). A customized, 12 mm, RGP contact lens was designed and manufactured. Two peripheral notches were customized to fit the hand position of the surgeon (at 11 O'clock and 2 Clock in this case series) to allow clear corneal incisions. Six eyes of 6 patients were included (3 eyes with advanced keratoconus and a severely optically distorted, yet clear corneas, planned for PK on the same day; 2 eyes were status post-intracorneal ring segment implantation for stage 4 keratoconus and 1 eye had combined phacoemulsification with superficial keratectomy to remove paracentral corneal Salzmann's nodule). Lens opacities ranged from +2 to +4 nuclear sclerosis in all eyes. Good visualization of the anterior lens and capsule attained with the RGP contact lens fitting. Improved visualization was reported during all the steps (Capsulorhexis, Irrigation/Aspiration, Phaco. Intraocular lens implantation). The phacoemulsification was smooth and non-complicated in a total of 6 eyes of 6 patients. In these cases, without RGP fitting, the operation was not technically possible. The customized notches allowed any insertion of surgical instruments, and with the help of viscoelastic maintained a good stability of the contact lens during the operation. We concluded that customized method RGP contact lens, may help reducing complications during phacoemulsification in advanced corneal ectasia and perhaps in irregular corneas as well.
...
PMID:A Modified Customized Rigid Gas Permeable Contact Lens to Improve Visualization During Phacoemulsification in Ectatic Corneas. 3197 37