Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0851184 (thinning)
11,252 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Hemoglobin solution has been proposed as a blood substitute and, when administered intravenously, causes hemodilution that affects the viscosity of the circulation fluid. To quantitate the changes in viscosity, hemodilutions were made by mixing freshly drawn human blood with a 7-g/dl hemoglobin solution in different proportions. Viscosity measurements were made with a micro-cone plate viscosimeter at various shear rates. The results demonstrate that even at low or moderate hemodilutions with hemoglobin solution, the viscosity of blood decrease considerably at each shear rate investigated. The decrease of viscosity is greater with increasing hemodilution. A shear thinning effect is observed with whole blood and with each hemodiluted sample. The viscosity-hematocrit relationship, which could be demonstrated not only by cone-plate but also by the Ostwald viscosimeters at a fixed shear rate, shows that the concentration of red blood cells significantly affects the viscosity of blood. Hemodilution of blood with hemoglobin solution not only reduces the viscosity but also may improve the blood flow.
...
PMID:Viscosity of human blood hemodiluted with crystalline hemoglobin solution. 731 27

The fundamental study of blood flow past a circular cylinder filled with an oxygen source is investigated as a building block for an artificial lung. The Casson constitutive equation is used to describe the shear-thinning and yield stress properties of blood. The presence of hemoglobin is also considered. Far from the cylinder, a pulsatile blood flow in the x direction is prescribed, represented by a time periodic (sinusoidal) component superimposed on a steady velocity. The dimensionless parameters of interest for the characterization of the flow and transport are the steady Reynolds number (Re), Womersley parameter (alpha), pulsation amplitude (A), and the Schmidt number (Sc). The Hill equation is used to describe the saturation curve of hemoglobin with oxygen. Two different feed-gas mixtures were considered: pure O(2) and air. The flow and concentration fields were computed for Re=5, 10, and 40, 0< or =A< or =0.75, alpha=0.25, 0.4, and Schmidt number, Sc=1000. The Casson fluid properties result in reduced recirculations (when present) downstream of the cylinder as compared to a Newtonian fluid. These vortices oscillate in size and strength as A and alpha are varied. Hemoglobin enhances mass transport and is especially important for an air feed which is dominated by oxyhemoglobin dispersion near the cylinder. For a pure O(2) feed, oxygen transport in the plasma dominates near the cylinder. Maximum oxygen transport is achieved by operating near steady flow (small A) for both feed-gas mixtures. The time averaged Sherwood number, Sh, is found to be largely influenced by the steady Reynolds number, increasing as Re increases and decreasing with A. Little change is observed with varying alpha for the ranges investigated. The effect of pulsatility on Sh is greater at larger Re. Increasing Re aids transport, but yields a higher cylinder drag force and shear stresses on the cylinder surface which are potentially undesirable.
...
PMID:Pulsatile blood flow and oxygen transport past a circular cylinder. 1740 25

Hemoglobin vesicles (HbV) or liposome-encapsulated Hbs are artificial oxygen carriers that have been developed for use as transfusion alternatives. The extremely high concentration of the HbV suspension (solutes, ca. 16 g/dL; volume fraction, ca. 40 vol %) gives it an oxygen-carrying capacity that is comparable to that of blood. The HbV suspension does not possess a colloid osmotic pressure. Therefore, HbV must be suspended in or co-injected with an aqueous solution of a plasma substitute (water-soluble polymer), which might interact with HbV. This article describes our study of the rheological properties of HbV suspended in a series of plasma substitute solutions of various molecular weights: recombinant human serum albumin (rHSA), dextran (DEX), modified fluid gelatin (MFG), and hydroxylethyl starch (HES). The HbV suspended in rHSA was nearly Newtonian. Other polymers-HES, DEX, and MFG-induced HbV flocculation, possibly by depletion interaction, and rendered the suspensions as non-Newtonian with a shear-thinning profile (10(-4)-10(3) s(-1)). These HbV suspensions showed a high storage modulus (G') because of the presence of flocculated HbV. However, HbV suspended in rHSA exhibited a very low G'. The viscosities of HbV suspended in DEX, MFG, and high-molecular-weight HES solutions responded quickly to rapid step changes in shear rates of 0.1-100 s(-1) and a return to 0.1 s(-1), indicating that flocculation is both rapid and reversible. Microscopically, the flow pattern of the flocculated HbV that perfused through microchannels (4.5 microm deep, 7 microm wide, 20 cmH2O applied pressure) showed no plugging. Furthermore, the time required for passage was simply proportional to the viscosity. Collectively, the HbV suspension viscosity was influenced by the presence of plasma substitutes. The HbV suspension provides a unique opportunity to manipulate rheological properties for various clinical applications in addition to its use as a transfusion alternative.
...
PMID:Rheological properties of hemoglobin vesicles (artificial oxygen carriers) suspended in a series of plasma-substitute solutions. 1756 54