Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0729233 (
Thoracic
)
6,478
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
A study was conducted to compare four gravimetric methods of measuring fine particle (PM2.5) concentrations in air: the BGI, Inc. PQ200 Federal Reference Method PM2.5 (FRM) sampler; the Harvard-Marple Impactor (HI); the BGI, Inc.
GK2
.05 KTL Respirable/
Thoracic
Cyclone (KTL); and the AirMetrics MiniVol (MiniVol). Pairs of FRM, HI, and KTL samplers and one MiniVol sampler were collocated and 24-hr integrated PM2.5 samples were collected on 21 days from January 6 through April 9, 2000. The mean and standard deviation of PM2.5 levels from the FRM samplers were 13.6 and 6.8 microg/m3, respectively. Significant systematic bias was found between mean concentrations from the FRM and the MiniVol (1.14 microg/m3, p = 0.0007), the HI and the MiniVol (0.85 microg/m3, p = 0.0048), and the KTL and the MiniVol (1.23 microg/m3, p = 0.0078) according to paired t test analyses. Linear regression on all pairwise combinations of the sampler types was used to evaluate measurements made by the samplers. None of the regression intercepts was significantly different from 0, and only two of the regression slopes were significantly different from 1, that for the FRM and the MiniVol [beta1 = 0.91, 95% CI (0.83-0.99)] and that for the KTL and the MiniVol [beta1 = 0.88, 95% CI (0.78-0.98)]. Regression R2 terms were 0.96 or greater between all pairs of samplers, and regression root mean square error terms (RMSE) were 1.65 microg/m3 or less. These results suggest that the MiniVol will underestimate measurements made by the FRM, the HI, and the KTL by an amount proportional to PM2.5 concentration. Nonetheless, these results indicate that all of the sampler types are comparable if approximately 10% variation on the mean levels and on individual measurement levels is considered acceptable and the actual concentration is within the range of this study (5-35 microg/m3).
...
PMID:A comparison of four gravimetric fine particle sampling methods. 1514 86
It has been suggested that the non-size-selective sampling methods currently used for fibrous aerosols potentially lead to the presence of large compact particles, agglomerates and fibre clumps in samples, which in turn reduce the accuracy and precision of the manual fibre counting techniques employed to analyse samples. The use of thoracic size-selective samplers has been proposed as an alternative, leading to the prevention of large particles reaching the collection substrate while at the same time bringing fibre sampling into line with general occupational aerosol sampling methodologies.
Thoracic
samplers should give good agreement with current sampling methods under ideal conditions based on aerodynamic fibre properties. However, the effect of fibre length on sampling efficiency is not known. The sampling efficiency of five thoracic samplers was therefore measured as a function of fibre length for respirable fibres between 10 and 60 microm long. These included the commercially available
GK2
.69 cyclone and the CATHIA sampler, the IOM thoracic sampler, a modified version of the SIMPEDS cyclone and a modified version of the IOM inhalable sampler. Length-monodisperse fibres were generated using a dielectrophoretic fibre classifier and sampler penetration was measured as a function of fibre length. No length-dependent sampling effects were observed for the CATHIA,
GK2
.69, modified SIMPEDS and modified IOM inhalable samplers for fibres <60 microm. Data for the IOM thoracic sampler showed a significant trend of reducing sampling efficiency for fibres >30 microm. Overall, the laboratory results indicated that the five sampler types are likely to perform as well as or better than the currently used 25 mm cowled sampler in the field.
...
PMID:Thoracic size-selection of fibres: dependence of penetration on fibre length for five thoracic sampler types. 1217 65