Indices of fluid balance were evaluated during and after aortic surgery in 16 consecutive patients.
Thoracic
electrical impedance (TI), heart rate (HR), central venous (CVP), pulmonary artery mean (
PAMP
), pulmonary wedge (PWP) and mean arterial (MAP) pressure as well as fourteen arterial and venous blood gas variables were followed. Consistent with a reduction of T1 by 4.2 (-5.2 to 9.2) Ohm (median and range) during the operation, fluid balance was in excess of 1.8 (-0.1 to 3.3) 1 when evaporation was not taken into account, and it remained elevated by 1.3 (0.0 to 5.4) 1 on the first postoperative morning. The HR, MAP and PWP remained stable, while CVP and
PAMP
decreased by 6 (-2 to 13) and 6 (-1 to 22) mmHg, respectively. Of the determined variables only TI revealed a meaningful correlation to fluid balance (rho = -0.41; P < 0.01). Haemoglobin concentrations increased in proportion to the administered packed erythrocytes, while arterial oxygen saturation, pH and base excess decreased in proportion to the excess fluid. The results indicate that while central venous and pulmonary artery mean pressures gave the impression of a volume deficit, the positive fluid balance was mirrored by thoracic electrical impedance, and that even a minor increase of fluid balance may affect pulmonary function in patients subjected to aortic surgery.
...
PMID:Thoracic electrical impedance and fluid balance during aortic surgery. 767 89
Indices of fluid balance were evaluated during and after aortic surgery in 16 consecutive patients.
Thoracic
electrical impedance (TI), heart rate (HR), central venous (CVP), pulmonary artery mean (
PAMP
), pulmonary wedge (PWP) and mean arterial (MAP) pressures as well as fourteen arterial and venous blood gas variables were followed. Consistent with a reduction of TI during the operation, fluid balance was in excess, and it remained elevated on the first postoperative morning. The HR, MAP and PWP remained stable, while CVP and
PAMP
decreased. Of the determined variables only TI revealed a meaningful correlation to fluid balance (rho = -0.41; p < 0.01). The results indicate that while central venous and pulmonary artery mean pressures gave the impression of a volume deficit, the positive fluid balance was mirrored by thoracic electrical impedance.
...
PMID:[Thoracic electric impedance and fluid balance during aortic surgery]. 896 7