Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0432222 (SEM)
47,337 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Ear oximetry was used to monitor arterial oxygenation in seven patients who had a history of frequent admissions for sickle cell crisis and were taking narcotic analgesics. Five full-night studies and seven daytime "nap" studies were performed in which sleep state was monitored by electroencephalography, and respiratory rate and tidal volume were monitored by inductance plethysmography. For all patients the mean (+/- SEM) of the median oxygenation values was 93.3% +/- 0.4% during wakefulness and 91.4% +/- 0.8% during sleep. During wakefulness the lowest saturation was 90% +/- 0.5%; during sleep there was a fall in the lowest oxygen saturation to 86.5% +/- 0.9%. In all patients a fall in oxygen saturation was associated with a decrease in respiratory depth without a change in respiratory frequency. The results indicate that in sickle cell disease oxygen saturation is lower during sleep than during wakefulness and that hypoxemia can be attributed to a fall in tidal volume.
...
PMID:Oxygen saturation with sleep in patients with sickle cell disease. 396 54