Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0432222 (
SEM
)
47,337
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
We report a study to test the feasibility of studying mineral density distributions in bone using the backscattered electron signal in scanning electron microscopy. Samples were human sixth ribs ranging in age from 8 weeks to 59 years, embedded in polymethylmethacrylate (PMMA), cut, polished, and carbon coated. The proportions of pixels falling in a uniform set of gray level slices of the
BSE
signal were determined using a microcomputer-based image analysis system interfaced directly to the
SEM
. The amount of high-density bone gradually increased with age at the expense of low-density bone, and there was an associated compression of the range of the mineral density distribution. Age-related differences were noted between the density distributions in the outer and inner rib cortices. The distribution in the inner cortex in neonates was influenced by the inclusion of densely mineralized endochondral bone and cartilage trabeculae formed at the growth cartilage zone. In adults it appeared that greater bone turnover occurred in the outer cortex, perhaps reflecting a differential mechanical loading across the rib. The technique enabled rapid, unbiased discrimination between the bone of neonates, children, and adults.
...
PMID:Changes in the mineral density distribution in human bone with age: image analysis using backscattered electrons in the SEM. 345 53
This article reviews the applications of
SEM
methods to human bone pathologies referring to studies made at UCL. We consider the methods which may be most suitable; these prove to be not "routine" in the context of most bio-medical applications of
SEM
. Valuable information can be obtained from a bone sample if its edges are ground flat, before making either a matrix surface preparation by washing away all the cells or a mineralizing front preparation, by also dissolving the osteoid-for which hydrogen peroxide is recommended to produce a robust specimen.
BSE
contrast from a cut block surface can be used to measure bone phase volume. SE contrasts from natural surfaces (trabeculae, canals and lacunae) can be used to study forming, resting and resorbing surfaces both qualitatively and quantitatively (except in the case of histological osteomalacia, where the existence of osteoid will go undetected and reversal lines will be difficult to distinguish from recently resorbed surfaces). We also recommend the use of PMMA embedded bone blocks, which can be used as obtained from the pathologist, but are better embedded by a more rigorous procedure.
BSE
image analysis can be used to quantitate bone density fractions opening up a completely new investigative method for the future. Osteoid can be measured automatically using CL if the bone sample is block stained with brilliant sulphaflavine before embedding or if a scintillant is added to the embeddant. We give examples of observations made from a number of bone diseases: vitamin D resistant rickets, osteogenesis imperfecta; osteomalacia; osteoporosis; hyperparathyroidism; fluorosis; Paget's disease; tumour metastasis to bone.
...
PMID:Scanning electron microscopy in bone pathology: review of methods, potential and applications. 354 96
Experiments using the CL imaging mode to recognise osteoid in the polished, cut surfaces of bone biopsies embedded in PMMA led to the development of a number of new methods for contrast formation in CL images in the
SEM
. These involve: (1) enhancing or (2) reducing the CL signal by staining the specimen, (3) utilising the cathodoluminescence of glass microscope slides to produce images of histological sections mounted on glass so that features in the section which scatter the electron beam appear dark against a light background, and (4) enhancing the CL signal from PMMA so that features which are less penetrated by the scintillator show up dark against a bright background. Efforts to increase the efficiency of light collection resulted in the development of a new means for manufacturing reflector-cum-light guide CL detectors by wrapping aluminum foil around a wooden former. These detectors enshroud the specimen so that CL light can only escape to the photomultiplier window (or back up the final lens). A variety of such designs have proved more efficient than the conventional plastic light guides used as CL detectors. By enlarging the beam entry aperture, other SE and
BSE
detectors can be used simultaneously. Examples of the value of the CL mode in mineralised tissue research include the use of enhanced CL plastic embedding media to detect marrow space and of enhanced osteoid CL to detect unmineralised bone matrix; the use of tetracycline as a growth marker in pathological studies of bone and experimental studies with bone, dentine and enamel; the use of bisbenzamid to locate and count nuclei in osteoclasts, the hard tissue resorbtive cells; and the use of superficial stain absorption of auto-CL to locate stained material on tooth surfaces, with the view to monitor the efficiency of periodontal therapy.
...
PMID:New methods for cathodoluminescence in the scanning electron microscope. 666 48
The quality of bone may be as important as its quantity, influencing bone strength and turnover. Using quantitative
BSE
(backscattered electron) imaging, we have found changes in the mineral density of bone with age, the proportion of denser bone increasing, and discontinuities occurring in the mineral phase between packets of bone.
SEM
of resorptive fields showed that severing of trabeculae occurs with deep, vertical excavations; their thinning is by long, narrow, resorption grooves extending from node to node. Grooved regions may become deeper, undercut and burrowing. In vitro, we showed that larger osteoclasts made larger pits. However, the volume of tissue resorbed per nucleus did not increase, and could decrease. Interactions between osteoclasts and autologous osteoblastic cells were observed by time-lapse video microscopy in vitro. Message-mediated contact behaviour, dependent upon the state of activation of both cell types, resulted in changes in the territory of the responding cell. The numbers and sizes of gap junctions between rat parietal bone cells in situ were investigated using confocal fluorescence and reflection microscopy and polyclonal antisera to connexin-43 peptides. The junctions reached approximately 1.3 microns in diameter, with 0.2 microns as the limit of detection. The extent of connectivity and communication may also affect bone quality.
...
PMID:Questions of quality and quantity--a morphological view of bone biology. 809 41
There are many ways available now to maximise and analyse the information that can be obtained on the structure and constitution of bone using
SEM
. This paper considers a range of methods and the problems that arise relating to instrumentation and methodology as they apply to the use of
SEM
in the study of bone. In addition to the review content, some novel technical approaches to the
SEM
of bone are considered here for the first time; these include low kV imaging for the detection of new surface bone packets (and residual demineralized matrix after resorption), low kV
BSE
imaging of uncoated, embedded, and unembedded samples, environmental
SEM
for the study of wet tissue, low distortion, very low magnification imaging for the study of cancellous bone architecture, the use of multiple detectors for fast electrons in improving the imaging of porous samples, and high resolution, low voltage imaging for the study of collagen degradation during bone resorption.
...
PMID:Scanning electron microscopy of bone: instrument, specimen, and issues. 884 22
The aim of this study was to investigate the extent of natural intrinsic fluorescence in carious human dentine and any correspondence of such autofluorescence (AF) to the mineral distribution within the lesion. Two investigative techniques were used, both employing the same sample set and fields in diamond-polished block surfaces of polymethylmethacrylate-embedded carious teeth. AF at emission wavelengths >515 nm, excited by 488-nm laser light, was assessed using a confocal laser scanning optical microscope (CLSM), the recordings made under standard operating conditions. The relative mineral content was assessed using digital backscattered scanning electron microscopy (20 kV
BSE
-
SEM
). The AF intensity correlated with the level of demineralisation as seen by
BSE
, but the depth of the lesion as seen by CLSM was significantly greater implying that the AF is not directly related to the mineral component.
...
PMID:Autofluorescence and mineral content of carious dentine: scanning optical and backscattered electron microscopic studies. 957 88
This work is the first to deal with the application of color cathodoluminescence scanning electron microscopy (CCL
SEM
) and a novel version of combined imaging with backscattered electrons (CCL +
BSE
SEM
) for the study of the composition of bile and its precipitation mechanisms. The present study demonstrates cholesterol, protein, and bilirubin distribution in deposits of normal and abnormal human bile after solution evaporation to full dryness. Qualitative CCL
SEM
analysis showed that dried bile remnants include different proportions of the above components. Three types of deposits were observed: Arborescent crystals, typical cholesterol crystals, and amorphous bilirubin particles. The selection of crystalline or amorphous precipitate phases is determined by the dehydration/concentration process. The findings may explain key features in lithogenesis.
...
PMID:The morphology and composition of cholesterol, protein, and bilirubin deposits in dried human bile: cathodoluminescence and backscattered electron imaging. 982 40
This study examined material from Thoroughbred horses, the majority of which had been in race training, for evidence of pathology in the third metacarpal (McIII) and third metatarsal (MtIII) bones which might be related to the occurrence of distal condylar fractures. Whole bone samples were studied and documented by macrophotography prior to macroradiography and computed tomographic (CT) imaging. Microradiographs were made from 100 microm thick mediolateral sections cut perpendicular to the dorsal and palmar/plantar articular surfaces of distal condylar regions of McIII and MtIII. Blocks were prepared for morphological imaging using the backscattered electron mode of scanning electron microscopy (
BSE
SEM
). Linear defects in mineralised articular cartilage and subchondral bone were found in the palmar/plantar aspects of the condylar grooves adjacent to the sagittal ridge. These were closely related to the pattern of densification of the subchondral bone and were associated with intense focal remodelling of the immediately adjacent and subjacent bone. Parasagittal fractures of the condyles originated in similar defects. A unifying hypothesis for the aetiopathogenesis of these fractures is presented.
...
PMID:Pathology of the distal condyles of the third metacarpal and third metatarsal bones of the horse. 1021 26
To help assess the immunological functions of the liver peritoneum, expression and 3D-microlocalization of adhesion molecules were studied by immuno-
SEM
and -TEM. The peritoneal tissues of the liver obtained from lipopolysaccharide (LPS, 1.5 microg/g BW for 24 hr)-stimulated (n = 18 including nine controls) and non-stimulated mice (n = 6 including three controls) were analyzed by immunolabeling with 15 nm gold particle single-labeling analysis of ICAM-1, ICAM-2, VCAM-1, MAdCAM-1, PECAM-1, ELAM-1, and CD105 expression. In addition, 10 and 20 nm gold particle double-labeling analysis of ICAM-1 and VCAM-1 was carried out with conventional TEM and
BSE
(backscatter electron) imaging. Gold particles detected in the peritoneal mesothelial cells were quantified using a computer analyzer, LUZEX III. Only ICAM-1 in non-stimulated mice and both ICAM-1 and VCAM-1 in LPS-stimulated mice were expressed on the mesothelium, but no other adhesion molecules were detected in either condition. Expression of ICAM-1 was consistently about four times greater than that of VCAM-1. Each adhesion molecule was restricted to the microvilli. ICAM-1 was expressed on all microvilli and tended to form clusters of three or four molecules. On the other hand, about 24% of the microvilli expressed VCAM-1 and less clustering was seen. Double-labeling techniques disclosed that VCAM-1 and ICAM-1 were rarely closely associated, usually spaced by about 40 nm. These results suggest that microvilli of the mesothelial cell play a significant role in leukocyte migration in the peritoneal cavity, by providing the important substrates for adhesion, ICAM-1 and VCAM-1.
...
PMID:Expression of adhesion molecules relevant to leukocyte migration on the microvilli of liver peritoneal mesothelial cells. 1060 47
Microbial life in the harsh conditions of Antarctica's cold desert may be considered an analogue of potential life on early Mars. In order to explore the development and survival of this epilithic and endolithic form of microbial life, our most sophisticated, state-of-the-art visualization technologies have to be used to their full potential. The study of any ecosystem requires a knowledge of its components and the processes that take place within it. If we are to understand the structure and function of each component of the microecosystems that inhabit lithic substrates, we need to be able to quantify and identify the microorganisms present in each lithobiontic ecological niche and to accurately characterize the mineralogical features of these hidden microhabitats. Once we have established the techniques that will allow us to observe and identify these microorganisms and mineral substrates in situ, and have confirmed the presence of water, the following questions can be addressed: How are the microorganisms organized in the fissures or cavities? Which microorganisms are present and how many are there? Additional questions that logically follow include: What are the existing water relationships in the microhabitat and what effects do the microorganisms have on the mineral composition? Mechanical and chemical changes in minerals and mineralization of microbial cells can give rise to physical and/or chemical traces (biomarkers) and to microbial fossil formation. In this report, we describe the detection of chains of magnetite within the Martian meteorite ALH84001, as an example of the potential use of
SEM
-
BSE
in the search for plausible traces of life on early Mars.
...
PMID:New approaches to the study of Antarctic lithobiontic microorganisms and their inorganic traces, and their application in the detection of life in Martian rocks. 1249 88
1
2
3
4
5
Next >>