Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0392326 (
discomfort
)
22,423
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Clinical examination is still the gold standard of postoperative free flap monitoring, but with intraorally situated and/or buried flaps, it can be difficult or impossible. Microdialysis is a sampling technique which offers the possibility to monitor the metabolism of a flap continuously. Ischemia can be detected by monitoring the changes in
glucose
, lactate, and pyruvate levels in interstitial fluid of the specific tissue. Our aim was to use microdialysis to monitor the metabolism of free flaps used for reconstructions inside the oral cavity/oropharynx and to evaluate the reliability and usefulness of this new monitoring method.Twenty-five consecutive patients who underwent oral cavity/oropharynx cancer resection and immediate reconstruction with free flap were included in the study. A microdialysis catheter was placed into the subcutaneous adipose tissue of the flap in the end of the surgical procedure. Dialysate samples were taken on an hourly basis for 72 hours postoperatively. Routine clinical monitoring was carried out by experienced nursing staff. Clinical findings were recorded and later compared with microdialysis values. Two flaps out of 25 failed in spite of reoperations. In both problem cases, microdialysis indicated ischemia 1 to 2 hours before it became clinically evident. During flap ischemia, the lactate/pyruvate ratio increased,
glucose
concentrations reduced, whereas lactate level increased when compared with normal values. Our results indicate that microdialysis is safe for the patient and the flap. It can reliably detect flap ischemia at an early stage. This is especially useful in buried flaps when clinical monitoring is difficult. Microdialysis may also reduce the patient
discomfort
caused by repeated clinical examination of the flap.
...
PMID:Microdialysis in clinical practice: monitoring intraoral free flaps. 1655 69
A new cookie test was developed for the simultaneous evaluation of multiple risk factors such as glucose intolerance, hyperinsulinemia, insulin resistance and postprandial dyslipidemia. The cookie consisting of 75 g carbohydrate and 25 g fat is ingested and the blood samples are obtained at 0, 1 and 2 hours later. When the two carbohydrate sources, liquid
glucose
and test cookie, were compared as a
glucose
load within 3 months, the 2 hr plasma
glucose
levels were not statistically different, proposing the use of the same criteria at 2 hour
glucose
level for the diagnosis of diabetes and impaired glucose tolerance (IGT) in subjects without exocrine pancreatic dysfunction. In addition, hyperinsulinemia, insulin resistance (AUC insulin, and/or AUC insulin X AUC
glucose
), and postprandial hyperlipidemia (DeltaTG, Triglyceride; DeltaRLP, remnant like particles) have been simultaneously uncovered. Reactive hypoglycemia with adverse epigastric
discomfort
was observed in 26.3% of the control subjects with liquid
glucose
, while it was observed in only 1 case (5.3%) without any symptom with cookie tests. In fact, one reactive hypoglycemia out of 5 with liquid
glucose
turned out to be IGT with cookie test. In 64 subjects with lifestyle-related diseases, cookie test revealed hyperinsulinemia and insulin resistance in 56% respectively, postprandial hyperlipidemia in 39%, diabetes and IGT in 22-23% of each of the subjects and all showed at least one abnormal value. In contrast, in university students with exercise habit, all showed normal results with cookie test. In addition, improved insulin sensitivity over non-exercise group was obverved. In summary, the cookie test provided more informations compared with OGTT using liquid
glucose
and with fewer side effects. Simultaneous evaluation of glucose intolerance, hyperinsulinemia, insulin resistance, and postprandial hyperlipidemia was also possible.
...
PMID:Development of cookie test for the simultaneous determination of glucose intolerance, hyperinsulinemia, insulin resistance and postprandial dyslipidemia. 1661 74
Hyperglycaemia is prevalent in critical illness and increases the risk of further complications and mortality, while tight control can reduce mortality up to 43%. Adaptive control methods are capable of highly accurate, targeted blood
glucose
regulation using limited numbers of manual measurements due to patient
discomfort
and labour intensity. Therefore, the option to obtain greater data density using emerging continuous
glucose
sensing devices is attractive. However, the few such systems currently available can have errors in excess of 20-30%. In contrast, typical bedside testing kits have errors of approximately 7-10%. Despite greater measurement frequency larger errors significantly impact the resulting
glucose
and patient specific parameter estimates, and thus the control actions determined creating an important safety and performance issue. This paper models the impact of the continuous
glucose
monitoring system (CGMS, Medtronic, Northridge, CA) on model-based parameter identification and
glucose
prediction. An integral-based fitting and filtering method is developed to reduce the effect of these errors. A noise model is developed based on CGMS data reported in the literature, and is slightly conservative with a mean Clarke Error Grid (CEG) correlation of R=0.81 (range: 0.68-0.88) as compared to a reported value of R=0.82 in a critical care study. Using 17 virtual patient profiles developed from retrospective clinical data, this noise model was used to test the methods developed. Monte-Carlo simulation for each patient resulted in an average absolute 1-h
glucose
prediction error of 6.20% (range: 4.97-8.06%) with an average standard deviation per patient of 5.22% (range: 3.26-8.55%). Note that all the methods and results are generalizable to similar applications outside of critical care, such as less acute wards and eventually ambulatory individuals. Clinically, the results show one possible computational method for managing the larger errors encountered in emerging continuous blood
glucose
sensors, thus enabling their more effective use in clinical
glucose
regulation studies.
...
PMID:Integral-based filtering of continuous glucose sensor measurements for glycaemic control in critical care. 1664 57
Cognitive dysfunction in multiple sclerosis (MS) is present in approximately 50% of the patients. Only moderate correlations have been found between cognitive dysfunction and T(2) lesion load, black holes or atrophy. Cognitive dysfunction in MS is probably related to the overall disease burden of the brain including abnormalities in normal appearing white matter (NAWM) and cortical grey matter, which is undetected with conventional magnetic resonance imaging (MRI). Hence, imaging techniques that embrace such abnormalities are needed to achieve better correlation with cognitive dysfunction. MR spectroscopy (MRS) performed with multi-slice echo planar spectroscopic imaging (EPSI) and PET measurements of brain metabolism as the cortical cerebral metabolic rate of
glucose
are imaging methods that are able to provide information on axonal loss or dysfunction in both MS lesions and in NAWM and cortical grey matter. Measurements of global NAA using multi-slice EPSI is a new promising method for measurement of the global neuron capacity and can be repeated with only little
discomfort
and without any risk for the patient.
...
PMID:The relationship between MRI and PET changes and cognitive disturbances in MS. 1665 Apr 36
In this study we investigated the effects of preoperative oral carbohydrate administration on postoperative insulin resistance (PIR), gastric fluid volume, preoperative
discomfort
, and variables of organ dysfunction in ASA physical status III-IV patients undergoing elective cardiac surgery, including those with noninsulin-dependent Type-2 diabetes mellitus. Before surgery, 188 patients were randomized to receive a clear 12.5% carbohydrate drink (CHO), flavored water (placebo), or to fast overnight (control). CHO and placebo were treated in double-blind format and received 800 mL of the corresponding beverage in the evening and 400 mL 2 h before surgery. Patients were monitored from induction of general anesthesia until 24 h postoperatively. Exogenous insulin requirements to control blood
glucose
levels <or=10.0 mmol/L were used as a marker for PIR. Gastric fluid volume was measured by passive gastric reflux and preoperative
discomfort
using visual analog scales. Postoperative clinical and surgical data were recorded. Blood
glucose
levels and insulin requirements did not differ between groups. Patients receiving CHO and placebo were less thirsty compared with controls (P < 0.01 and P = 0.06, respectively). Ingested liquids did not cause increased gastric fluid volume or other adverse events. The CHO group required less intraoperative inotropic support after initiation of cardiopulmonary bypass weaning (P < 0.05). In conclusion, preoperative CHO administration before cardiac surgery does not affect PIR. Clear fluids reduce thirst and may be recommended as a safe procedure in ASA III-IV patients. Further research is indicated to investigate possible cardioprotective effects of preoperative CHO intake.
...
PMID:Preoperative oral carbohydrate administration to ASA III-IV patients undergoing elective cardiac surgery. 1705 39
Currently finger pricking is the common method of blood
glucose
measurement in patients with diabetes mellitus. However, diabetes patients have proven to be reluctant to check their
glucose
profiles regularly because of the
discomfort
associated with this technique. Recently, a non-invasive and continuous Reverse Iontophoresis based
Glucose
Monitoring Device (RIGMD) was developed in Korea. The study was conducted during the period November 2003-January 2004 on 19 in-patients.
Glucose
measurements were performed using RIGMD between 10 a.m. and 4 p.m. Concurrent plasma
glucose
levels were checked hourly and subsequently compared with RIGMD data. The mean error of RIGMD measurements was -3.45 +/- 52.99 mg/dL with a mean absolute relative error of 20+/-15.16%. Measurements obtained by RIGMD were correlated with plasma
glucose
levels (correlation coefficient; 0.784 (p<0.05)) and this correlation was independent of time of data collection. However, after excluding confounding variables this correlation coefficient exhibited a tendency to increase. 98.9% of the results were clinically acceptable by Clarke error grid analysis. We concluded that RIGMD does not have the reliability and accuracy required to wholly replace conventional methods. However, further technical advancements that reduce its shortcomings would make this device useful for the management of diabetes.
...
PMID:Clinical experience of an iontophoresis based glucose measuring system. 1729 54
Shift work has been associated with a number of health problems including cardiovascular disease, impaired
glucose
and lipid metabolism, gastrointestinal
discomfort
, reproductive difficulties, and breast cancer. The specific contributions of disturbed physiological rhythms, circadian misalignment, and sleep debt to the various medical problems encountered by shift workers remain to be clarified. Fatigue can be caused by extended on-duty and/or waking periods, inadequate sleep quantity, sleep disturbances, disruption of circadian rhythms, and difficult work and familial conditions. Fatigue-related accidents raise a safety concern for shift workers, especially at the end of the night when the circadian nadir of alertness interacts with increased time awake. Individuals vary greatly in their capacity to adjust to atypical work schedules and their tolerance to circadian misalignment. Predisposing individual and domestic factors have been identified, such as increasing age, being a single woman in charge of children, and split sleep patterns, all of which can affect the ability to adjust to atypical schedules. However, prior studies indicate that predisposing individual and social determinants are generally poor predictors of shift work tolerance in a given individual. In this manuscript, we review several countermeasures to improve adaptation to shift work.
...
PMID:Working on atypical schedules. 1748 49
The combination of pioglitazone hydrochloride, a thiazolidinedione, and glimepiride, a sulfonylurea, has been approved in many countries worldwide as an oral agent for the management of type 2 diabetes. Glimepiride stimulates insulin secretion from the pancreas with a decreased risk of hypoglycemia compared to glyburide. Pioglitazone increases
glucose
uptake in the periphery while decreasing
glucose
production by the liver. Combined, the two agents increase the body's sensitivity to insulin to reduce hemoglobin A1c levels by 1-2%. Pioglitazone and glimepiride also produce favorable effects on lipid profiles and blood pressure. Additionally, pioglitazone has proven to decrease the risk of certain cardiovascular events, providing evidence for macrovascular benefits. Side effects are minimal with pioglitazone and glimepiride, with weight gain and edema providing the most
discomfort
and complications. Patients must be monitored for the development of heart failure, though the risk is small. Guidelines are in place to limit patient selection for the use of pioglitazone based on cardiac risk factors. In general, pioglitazone and glimepiride are well tolerated.
...
PMID:Pioglitazone hydrochloride/glimepiride. 1772 49
Gastroparesis is a disorder of gastric emptying that occurs in the absence of mechanical obstruction. Its cardinal features include nausea, vomiting, bloating, early satiety and
discomfort
. Weight loss, dehydration, electrolyte disturbances and malnutrition may develop in severe cases. The majority of cases is idiopathic, long standing diabetes mellitus is responsible for about 25-30% of cases. Diabetic gastroparesis may render
glucose
control extremely difficult, its treatment represents a major challenge. Besides frequent, small meals and psychological support, several drug options are available, however, their efficacy is limited and only a few randomized studies have been performed to date. Prokinetic agents (erythromycin, domperidone, metoclopramide) and antiemetics (phenothiazines, serotonin antagonists, butyrophenones) are the most wide-spread medicaments. Among the novel, recently developed agents, 5-HT4 serotonin receptor agonists and dopamine D2 receptor antagonists are the most promising. Injection of botulinum toxin into the pyloric sphincter resulted in faster gastric emptying and symptom alleviation in some studies. Gastric electric stimulation appears to be one of the most effective options, both low and high-frequency stimulation may alleviate symptoms. Gastrostomy/jejunostomy and other surgical interventions are considered as "last resort".
...
PMID:[Gastroparesis and its treatment options]. 1829 33
A 42-year-old woman presented with a 12-year history of extensive yellow and erythematous plaques, round and oblong with irregular configuration and glossy atrophic central areas on the pretibial aspects of both legs. Her 45-year-old sister presented with a 7-year history of a single plaque with erythematous margins, abundant telangiectases, and an atrophic center in the lower portion of the left leg. There was no family history of type-1 or type-2 diabetes mellitus. Both patients had normal fasting
glucose
concentration, oral
glucose
tolerance test, and
glucose
overload test. Different treatment options including topical corticosteroids were unsuccessful. Treatment with oral fumaric acid esters was attempted but the medication was discontinued because of intolerable side effects (flushing and gastrointestinal
discomfort
). At present, after a follow-up of 2 years, the plaques remain unchanged. These two cases should be added to the few cases of familial nondiabetic necrobiosis lipoidica previously reported.
...
PMID:Familial necrobiosis lipoidica not associated with diabetes. 1832 20
<< Previous
1
2
3
4
5
6
7
8
9
10
Next >>