Query: UMLS:C0376358 (
prostate cancer
)
59,338
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Temporary metallic intraprostatic stent is a new alternative treatment for patients with urinary obstructive syndrome caused by
prostate cancer
. Definitive radiotherapy is a treatment of choice for localized
prostate cancer
. This study evaluates in vitro the effect of a urethral intraprostatic metallic stent on the dose absorbed by the surrounding tissue. The study was designed to mimic the conditions under which the prostatic stent is placed in the body during pelvic irradiation. A urethral stent composed of a 50% nickel-50%
titanium
alloy (Uracoil-InStent) was imbedded in material mimicking normal tissue (bolus) at a simulated body depth of 10 cm. The distribution of the absorbed dose of irradiation was determined by film dosimetry using Kodak X-Omat V film. Irradiation was done in a single field at the isocenter of a 6 MV linear accelerator with a field size of 7 x 7 cm. The degree of film blackening was in direct proportion to the absorbed dose. The measurements showed an increase in dose of up to 20% immediately before the stent and a decrease of up to 18% immediately after the stent. These changes occurred within a range of 1-3 mm from both sides of the stent. In practice, irradiation in
prostate cancer
is given by two pairs of opposed co-axial fields; a total of four fields (Box Technique). The dose perturbations are partly cancelled in a pair of opposed beams resulting in a net variation of +/- 4%; therefore, the presence of the intraprostatic stent should not influence radiotherapy planning for
prostate cancer
.
...
PMID:Dose perturbation due to the presence of a prostatic urethral stent in patients receiving pelvic radiotherapy: an in vitro study. 924 65
The problem of dose perturbation due to hip prostheses during pelvic irradiation can be significant. Dose attenuation by a commonly used
titanium
alloy hip prosthesis was measured. Depending on the energy of the radiation beam and the thickness along the prosthesis, the attenuation was between 32% and 64%. This attenuation effect should be considered in treatment planning, especially in a patient with bilateral hip prostheses and when undergoing treatment for
prostate cancer
where the tumor typically lies between prostheses.
...
PMID:Dose attenuation through a titanium alloy hip prosthesis. 1075 12
An osmotically driven implantable system was designed and characterized for the delivery of leuprolide over a year-long duration. Leuprolide has been used in the treatment of
prostate cancer
since the 1980s. The DUROS implant consists of a
titanium
alloy cylinder, measures 4 mm in diameter by 45 mm in length and holds approximately 150 microl of formulation. Stability studies indicated that leuprolide was stable, as a solution formulation in DMSO, for several years at 37 degrees C. In vitro release rate testing, at weekly intervals, showed zero-order delivery for 1 year. DUROS implants demonstrated release rates that were reproducible and similar to one another after storage at 25 degrees C for 18 months prior to testing. In vivo studies, with implants placed subcutaneously, revealed delivery rates comparable to those observed under in vitro conditions. Leuprolide stability was also comparable between in vivo and in vitro conditions. Steady leuprolide serum levels produced by the implant resulted in the desired pharmacodynamic efficacy endpoint of testosterone suppression, both in canines and in humans. The good agreement between in vivo/in vitro delivery rates was as expected for a delivery system based on the principles of osmosis.
...
PMID:An in vivo/in vitro comparison with a leuprolide osmotic implant for the treatment of prostate cancer. 1145 92
The adsorption of iodine-125 on silver wire bits coated with palladium to be sealed in
titanium
capsules as brachytherapy sources was studied. A method was optimized to obtain quantitative adsorption of 125I on the palladium treated silver wires. A comparative evaluation of palladium coated and uncoated (bare) silver wires on the adsorption of 125I was made. While, the adsorption of bare silver wires showed low, inconsistent uptake (approximately 60%) of 125I with high leachability (approximately 4%), the Pd coated silver wires showed quantitative and consistent uptake of 125I (approximately 90%) and exhibited low leachability (0.01%). 125I adsorbed on Pd coated silver wires could be used as a matrix for the preparation of interstitial sources in eye and
prostate cancer
therapy.
...
PMID:A novel approach for the adsorption of iodine-125 on silver wire as matrix for brachytherapy source for the treatment of eye and prostate cancer. 1220 Nov 43
The use of low-energy photon emitters for brachytherapy applications, as in the treatment of prostate or ocular tumours, has increased significantly over the last few years. Several new seed models utilizing 103Pd and 125I have recently been introduced. Following the TG43U1 recommendations of the AAPM (American Association of Physicists in Medicine) (Rivard et al 2004 Med. Phys. 31 633), dose distributions around these low-energy photon emitters are characterized by the dose rate constant, the radial dose function and the anisotropy function in water. These functions and constants can be measured for each new seed in a solid phantom (i.e. solid water such as WT1) using high spatial resolution detectors such as very small thermoluminescent detectors. These experimental results in solid water must then be converted into liquid water by using Monte Carlo simulations. This paper presents the dosimetric parameters of a new palladium seed, OptiSeed (produced by International Brachytherapy (IBt), Seneffe, Belgium), made with a biocompatible polymeric shell and with a design that differs from the hollow
titanium
encapsulated seed, InterSource103, produced by the same company. A polymer encapsulation was chosen by the company IBt in order to reduce the quantity of radioactive material needed for a given dose rate, and to improve the symmetry of the radiation field around the seed. The necessary experimental data were obtained by measurements with LiF thermoluminescent dosimeters (1 mm3) in a solid water phantom (WT1) and then converted to values in liquid water using Monte Carlo calculations (MCNP-4C). Comparison of the results with a previous study by Reniers et al (2002 Appl. Radiat. Isot. 57 805) shows very good agreement for the dose rate constant and for the radial dose function. In addition, the results also indicate an improvement in isotropy compared to a conventional
titanium
encapsulated seed. The relative dose (anisotropy value relative to 90 degrees ) from the seed at a distance of 3 cm is close to 70% at 0 degrees whereas that for the
titanium
encapsulated InterSource103seed is close to 40%. This paper also presents some new Monte Carlo calculations relating to shadowing produced by the seeds in an array implanted for a
prostate cancer
treatment. Recently, Mobit and Badragan (2004 Phys. Med. Biol. 49 3171) reported shadowing resulting in a 10% decrease in dose from
titanium
encapsulated 125I seed. We used Monte Carlo simulations (MCNP-4C) to evaluate shadowing for the InterSource103
titanium
encapsulated seed and the OptiSeed polymer encapsulated seed. For a specific geometry specified, dose decreases of 13% and 7% were found for the InterSource103
titanium
encapsulated and the OptiSeed polymer encapsulated seed, respectively.
...
PMID:Dosimetric study of a new polymer encapsulated palladium-103 seed. 1579 39
Ultrasound-guided brachytherapy using
titanium
-shelled radioactive seeds is a popular, effective means of treating
prostate cancer
. Unfortunately, implantation using needles inserted transperitoneally causes gland movement and distortion, which often results in seed misplacement and dosimetry errors. If actual seed locations could be determined in the operating room, then corrections to dosimetry errors could be made immediately. However, seed specularity, shadowing, and tissue clutter make imaging seeds difficult using conventional ultrasound. Singular spectrum analysis (SSA) shows promise for reliably imaging radioactive seeds implanted in the prostate and enabling additional corrective implantations to be made in the operating room. SSA utilizes eigenvalues derived from the diagonalized correlation matrix of envelope-detected radio-frequency echo signals to yield a P value indicative of the likelihood of a seed-specific repetitive signal. We demonstrated the potential of SSA for seed detection and imaging and illustrated the trade-off considerations for optimization of SSA in clinical applications using simulations assessing performance as a function of different levels of noise and the presence of repetitive signals with various repetition periods; experiments in an ideal scattering environment; and experiments using seeds implanted in beef.
...
PMID:Singular spectrum analysis applied to ultrasonic detection and imaging of brachytherapy seeds. 1740 16
Transrectal-ultrasound-guided brachytherapy uses small
titanium
-shelled radioactive seeds to locally treat
prostate cancer
. During the implantation procedure, needles inserted transperitoneally cause gland movement resulting in seed misplacement and suboptimal dosimetry. In a previous study, an algorithm based on singular spectrum analysis (SSA) applied to envelope-detected ultrasound signals was proposed to determine seed locations [J. Mamou and E. J. Feleppa, J. Acoust. Soc. Am. 121, 1790-1801 (2007)]. Successful implementation of the SSA algorithm could allow correcting dosimetry errors during the implantation procedure. The algorithm demonstrated promise when the seed orientation was parallel to the needle and normal to the ultrasound beam. In this present study, the algorithm was tested when the seed orientation deviated up to 22 degrees from normality. Experimental data from a seed in an ideal environment and in beef were collected with a single-element, spherically focused, 5 MHz transducer. Simulations were designed and evaluated with the algorithm. Finally, objective quantitative scoring metrics were developed to evaluate the algorithm performance and for comparison with B-mode images. The results quantitatively established that the SSA algorithm always outperformed B-mode images and that seeds could be detected accurately up to a deviation of approximately 10 degrees .
...
PMID:Angle-dependent ultrasonic detection and imaging of brachytherapy seeds using singular spectrum analysis. 1839 22
Photocatalyzed
titanium
dioxide (TiO2) nanoparticles have been shown to eradicate cancer cells. However, the required in situ introduction of ultraviolet light limits the use of such a therapy in humans. In the present study the nonphotocatalytic anticancer effect of surface-functionalized TiO2 was examined. Nanoparticles bearing -OH, -NH(2), or -COOH surface groups were tested for their effect on in vitro survival of several cancer and control cell lines. The cells tested included B16F10 melanoma, Lewis lung carcinoma, JHU
prostate cancer
cells, and 3T3 fibroblasts. Cell viability was observed to depend on particle concentrations, cell types, and surface chemistry. Specifically, -NH(2) and -OH groups showed significantly higher toxicity than -COOH. Microscopic and spectrophotometric studies revealed nanoparticle-mediated cell membrane disruption leading to cell death. The results suggest that functionalized TiO2, and presumably other nanoparticles, can be surface-engineered for targeted cancer therapy.
...
PMID:Surface chemistry influences cancer killing effect of TiO2 nanoparticles. 1850 86
Permanent implantation of 125I (iodine) or 103Pd (palladium) sources is a popular treatment option in the management of early stage
prostate cancer
. New sources are being developed, some of which are being marketed for different clinical applications. A new technique of adjuvant stereotactic permanent seed breast implant, similar to that used in the treatment of
prostate cancer
, has been proposed by [N. Jansen et al., Int. J. Radiat. Oncol. Biol. Phys. 67, 1052-1058 (2007)] with encouraging results. The presence of artifacts from the metallic seeds, however, can disturb follow-up imaging. The development of plastic seeds has reduced these artifacts. This paper presents a feasibility study of the advantages of palladium-103 seeds, encapsulated with a biocompatible polymer, for future clinical applications, and on the effect of the gold marker on the dosimetric characteristics of such seeds. Experimental palladium seeds, OptiSeedexp, were manufactured by International Brachytherapy (IBt), Seneffe, Belgium, from a biocompatible polymer, including the marker. Apart from the absence of a gold marker, the studied seed has an identical design to the OptiSeed103 [Phys. Med. Biol. 50, 1493-1504 (2005)]; [Appl. Radiat. Isot. 63, 311-321 (2005)]. Polymer encapsulation was preferred by IBt in order to reduce the quantity of radioactive material needed for a given dose rate and to reduce the anisotropy of the radiation field around the seed. In addition, this design is intended to decrease the interseed effects that can occur as a result of the marker and the encapsulation. Dosimetric measurements were performed using LiF thermoluminescent dosimeters (1 mm3) in solid water phantoms (WT1). Measured data were compared to Monte Carlo simulated data in solid water using the MCNP code, version 4C. Updated cross sections [Med. Phys. 30, 701-711 (2003)] were used. As the measured and calculated data were in agreement, Monte Carlo calculations were then performed in liquid water to obtain relevant dosimetric data as required by TG-43U1 recommendations. Comparison of the results with previous studies of OptiSeed103 [Phys. Med. Biol. 50, 1493-1504 (2005)]; [Appl. Radiat. Isot. 63, 311-321 (2005)], and of InterSource103 [Appl. Radiat. Isot. 57, 805-811 (2002)] showed very good agreement for the dose rate constant and for the radial dose function. With respect to the anisotropy function, the relative dose (anisotropy value relative to 90 degrees) from the polymer seed at a distance of 3 cm was close to unity (105%) at 0 degrees, whereas the relative values for the OptiSeed103 with a gold marker and the
titanium
-encapsulated InterSource103 seed decreased to 70% and 40%, respectively. The interseed effect from one seed was negligible and in the order of calculation uncertainty, making calculation of the dose rate distribution of the studied seeds, according to TG43U1 recommendations, more accurate and closer to reality. This feasibility study shows that due to the low energy of palladium-103, the negligible interseed effect and the reduced artifacts in postimplant medical imaging, this experimental plastic seed would be a good source for breast brachytherapy. This feasibility study was carried out in collaboration with IBt and will be continued with a study of its visibility in different tissues.
...
PMID:An experimental palladium-103 seed (OptiSeedexp) in a biocompatible polymer without a gold marker: characterization of dosimetric parameters including the interseed effect. 1961 Mar 24
Brachytherapy to treat
prostate cancer
uses transrectal ultrasound to guide implantation of
titanium
-shelled radioactive seeds. Transperitoneal implantation allows errors in placement that cause suboptimal dosimetry. Conventional ultrasound cannot reliably image implanted seeds; therefore, seed misplacements cannot be corrected in the operating room. Previously, an algorithm based on singular spectrum analysis was shown to image palladium seeds better than B-mode ultrasound could. The algorithm is now applied to imaging an iodine seed in gel and in beef tissue as a function of seed angle relative to the incident ultrasound. Results indicate that both seed types are imaged reliably by the algorithm.
...
PMID:Angle-dependent ultrasonic detection and imaging of two types of brachytherapy seeds using singular spectrum analysis. 1920 92