Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0348321 (Haemophilus)
15,372 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

A total of 180 strains of Haemophilus influenzae and 119 strains of Haemophilus parainfluenzae were characterized with respect to biotype (i.e., production of indole, urease, and ornithine decarboxylase) using conventional biochemical methods and two commercially available biotyping systems: Trio-Tube Haemophilus system (Carr Microbiologicals) and the Rapid NH System (Inovative Diagnostic Systems). Concordance between the results of the Trio-Tube system and conventional biochemicals was achieved with 294 of the 299 test organisms (98.3%). With the Rapid NH System, concordance with the results of conventional biochemical tests was observed with 275 of the 299 tests strains (92.0%). One previously unrecognized biotype of H. parainfluenzae, designated biotype VIII, is described. Typical reactions of this biotype include indole production but no production of urease or ornithine decarboxylase.
...
PMID:Determination of biotypes of Haemophilus influenzae and Haemophilus parainfluenzae a comparison of methods and a description of a new biotype (VIII) of H. parainfluenzae. 350 12

Three commercially available systems, the 4-h Minitek Enterobacteriaceae III, the Haemophilus Trio-Tube, and the Micro-ID, were evaluated for their capacities to identify and biotype 308 respiratory isolates of Haemophilus spp. When compared with aminolevulinic acid test results, the definitive identification method used in this study, these systems demonstrated no significant differences in their capacities to differentiate Haemophilus influenzae from Haemophilus parainfluenzae. They were in agreement with the standard method of species identification approximately 50% of the time. When sucrose was added to the Minitek and Trio-Tube configurations, the efficiency rate of species identification increased to more than 95%. The Micro-ID could not be modified to incorporate this additional biochemical parameter. The performance of the sucrose-supplemented Minitek and Trio-Tube systems, compared to the combined results of Micro-ID and aminolevulinic acid, produced correlations of 94 and 90%, respectively. Rapid and accurate methodologies are available for combined species identification and biotyping of Haemophilus spp.
...
PMID:Rapid species identification and biotyping of respiratory isolates of Haemophilus spp. 663 Apr 35