Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0345904 (liver cancer)
15,188 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

We used phosphorus magnetic resonance spectroscopy (31P-MRS) to assess in vivo the brain bioenergetics of 28 patients with liver cirrhosis. Seven had clinical hepatic encephalopathy (HE), nine hepatocellular carcinoma. 31P-MRS was performed by the DRESS localisation technique on occipital lobes. Brain phosphocreatine was significantly reduced in patients with or without overt HE, and inorganic phosphate was increased in both groups of patients. The cytosolic phosphorylation potential (PP), the relative rate of oxidative metabolism and the regulatory [ADP] were all abnormal. Brain PP was inversely correlated with serum ammonia concentration only in patients without liver cancer. The degree of bioenergetic failure was significantly higher in the presence of overt encephalopathy. We conclude that patients with liver cirrhosis had a derangement of brain energy metabolism, and that 31P-MRS offers a non-invasive method for investigating the underlying mechanisms of HE, with relevant implications in the identification and management of this condition.
...
PMID:Abnormal brain energy metabolism shown by in vivo phosphorus magnetic resonance spectroscopy in patients with chronic liver disease. 1237 52

A solitary liver nodule about 1cm in diameter was detected in a 68-year-old male HBV carrier during therapy for advanced lung cancer. A multiple IIc-like depressed lesion originating in the stomach soon became elevated as the liver lesion progressed. HE staining produced hepatoma-like histological findings for the tumors of the lung, liver and stomach, while immunohistochemical staining showed them to be positive for PIVKA-II and weakly positive for HP-1. Autopsy led to a diagnosis of a moderately differentiated hepatocellular carcinoma producing bile juice with metastasis to the lung and stomach. It is not clear why advanced metastasis in the lung occurred while the hepatocellular carcinoma in the liver was still small, but one possible explanation lies in the localization of the hepatic cancer: the tumor was located near a branch of the hepatic vein and vascular invasion may have caused early pulmonary metastasis via the hepatic venous flow.
...
PMID:[Case of moderately differentiated hepatocellular carcinoma with gastric metastasis]. 1833 6

A 58-year-old man was followed up for HBV-associated chronic hepatitis. A low echoic hepatic nodule 1.6cm in diameter developed in segment 8 of the liver. The tumor was hypervascular and showed enhancement on CV during hepatic arteriography (CTHA) and a defect on CT during arterial portography (CTAP). Strong enhancement, which lasted for 30 seconds, was observed at the margin of the tumor on single-level dynamic CTHA. The resected tumor was whitish, had no capsule, and consisted mainly of intermediate immature cells together with HCC-like and CCC-like tumor cells. These findings led to the diagnosis of primary liver carcinoma of intermediate (hepatocyte-cholangiocyte) phenotype. Cytokeratin (CK) 7, CK8, CK19, EMA and vimentin were positive and HP-1 and c-kit tests were negative on immunohistochemical staining. Staining with CD34+alphaSMA showed more muscular arterial vessels and sinusoid-like vessels in the peripheral zone of the tumor than in the central zone. Six months after the resection of the tumor, swollen abdominal lymph nodes were observed on US and CT, which aspiration needle biopsy showed to be metastasis of a hepatic tumor.
...
PMID:[A case of primary liver carcinoma of intermediate (hepatocyte-cholangiocyte) phenotype: comparison of hemodynamics and histopathology]. 2020 49

To investigate the clinical value of 1H magnetic resonance spectroscopy (1H MRS) in the evaluation of high intensity focused ultrasound (HIFU) ablation for primary liver cancer. Routine magnetic resonance sequences, contrast-enhanced magnetic resonance imaging and respiratory-triggered single voxel point resolved spectroscopy sequence (PRESS) were performed on 24 patients with primary liver cancer before and after HIFU ablation. A respiratory-triggered axial T2 weighted imaging (T2WI) was used as localizer for PRESS. Spectroscopy data was transmitted to a personal computer and was post-processed with a custom software (Saker, provided by Ning Jing, an engineer in GE Healthcare). It would be considered "technical success" if the baselines of spectra were stable and main metabolites were without overlapping and could be identified. Integral areas of choline (Cho) peak at 3.2 parts per million (ppm) and lipid (Lip) peak at 1.3 ppm were measured, and the choline to lipid (Cho/Lip) ratios were calculated. The differences of areas of Cho, Lip peak and Cho/Lip ratios before and after HIFU ablation were compared by using paired samples t test, and a P value of less than 0.05 was considered statistically significant. The technical success rate of 1H-MRS was 87.50% (42/48). Integral areas of Cho peak and Lip peak of 20 patients with satisfied spectra were measured, and the Cho/Lip ratios were calculated. The Integral area of Cho peak decreased from 34 597+/-6 802 before HIFU ablation to 6 372+/-2 466 after HIFU ablation (t = 18.02, P less than 0.01). The Integral area of Lip peak increased from 147 948+/-16 317 before HIFU ablation to 149 069+/-16 345 after HIFU ablation (t = -15.11, P less than 0.01). The Cho/Lip ratio decreased from 0.23+/-0.03 before HIFU ablation to 0.04+/-0.02 after HIFU ablation (t = 25.32, P less than 0.01). 1H-MRS could provide information of metabolites changes of primary liver cancer after HIFU ablation and could be used as a complementary sequence to other magnetic resonance sequences to evaluate all around primary liver cancer after HIFU ablation.
...
PMID:[1H magnetic resonance spectroscopy in the evaluation of high intensity focused ultrasound ablation for primary liver cancer]. 2149 11

13C magnetic resonance spectroscopy is a viable, non-invasive method to study cell metabolism in skeletal muscles. However, MR sensitivity of 13C is inherently low, which can be overcome by applying a higher static magnetic field strength together with radiofrequency coil arrays instead of single loop coils or large volume coils, and 1H decoupling, which leads to a simplified spectral pattern. 1H-decoupled 13C-MRS requires RF coils which support both, 1H and 13C, Larmor frequencies with sufficient electromagnetic isolation between the pathways of the two frequencies. We present the development, evaluation, and first in vivo measurement with a 7 T 3-channel 13C and 4-channel 1H transceiver array optimized for 1H-decoupled 13C-MRS in the posterior human calf muscles. To ensure minimal cross-coupling between 13C and 1H arrays, several strategies were combined: mutual magnetic flux was minimized by coil geometry, two LCC traps were inserted into each 13C element, and band-pass and low-pass filters were integrated along the signal pathways. The developed coil array was successfully tested in phantom and in vivo MR experiments, showing a simplified spectral pattern and increase in signal-to-noise ratio of approximately a factor 2 between non-decoupled and 1H-decoupled spectra in a glucose phantom and the human calf muscle.
...
PMID:Proton-decoupled carbon magnetic resonance spectroscopy in human calf muscles at 7 T using a multi-channel radiofrequency coil. 2967 Jan 77