Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0312414 (Spotting)
88 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

The Fertility Control Clinic, National University Hospital in Singapore carried out this study between Jan.1988-Dec.1988. In a comparison of present and past users of contraceptive implants (Norplant) or injectables (DMPA) and discontinuers of Norplant or DMPA, information concerning the women's knowledge and perception of, and attitude to, implants and injectable contraceptives, was studied. 200 married women ages 20-45 with at least 1 living child, who had used either method for at least 1 year, took part in this survey. The long duration of action (5 years) of implants was perceived positively by all groups as compared to the shorter 3-month duration of injectables, though this was seen as an advantage over the pill. 69% of implant users expressed a desire to continue using them, but only 30.7% of the injectable users wanted to continue using the method. 60% of the injectable users wanted to switch to implants, whereas no implant users desired a change. Women stopped using these 2 methods mainly because of the desire for a future pregnancy, menstrual spotting, and absence of menses. Norplant seems to be the ideal contraceptive in Singapore for women who do not want any more children or irreversible contraception.
...
PMID:Attitudes towards contraceptive implants and injectables among present and former users in Singapore. 210 23

Women who received Norplant contraceptive implants from any of fifteen clinical settings in southeast Texas, U.S.A., were followed for one year to determine their reactions to the method. Of 1,385 who enrolled to receive Norplant implants, 1,253 had implants inserted. Side effects were reported by 78% of those receiving implants and 70% described changes in bleeding patterns. Spotting or irregular bleeding, weight gain and headaches were the conditions reported most frequently. Nine pregnancies were reported during the study period. Six of these, however, existed before the implants were inserted. At the one year anniversary, 143 of women receiving implants had had them removed. Those who discontinued method use were less satisfied, reported more side effects and were more likely to have planned to have another child, thus using the method for spacing, or to have had a change in their marital status while they were using the contraceptive. Providers should counsel patients to focus attention on plans for the future in selecting their contraceptive method. In addition, we recommend, as does the product's distributor, that providers confirm that patients are not pregnant prior to inserting implants.
...
PMID:One-year experience with subdermal contraceptive implants in the United States. 822 53

The objectives of this study were to evaluate the bleeding patterns and clinical performance during the first 2 years of use of an intrauterine system releasing 20 microg/day of levonorgestrel (LNG-IUS, Mirena). Two-hundred-fifty-six women accepted use of Mirena from April 1998 through September 1998. The gross cumulative discontinuation rate due to pregnancy and expulsion were significantly higher in women who used the device because of heavy bleeding. There was one pregnancy at the 15th month of use after an inadvertent expulsion of the device. The continuation rate was 66.2 at the end of the second year. Forty-four percent of women reported amenorrhea at the 6th month of use. This rate maintained stability at 50% after 12 and 24 months of use. Spotting was present in 25% of the users at 6 months, decreasing to 8% and 11% at 18 and 24 months, respectively. Oligomenorrhea was described by one-quarter of women and was similar at each observation period. Removals due to menstrual bleeding problems were concentrated in the first 6 months of use and mostly due to amenorrhea or menorrhagia. In conclusion, LNG-IUS showed a high contraceptive efficacy and a good continuation rate up to 2 years. In addition, a reduction of blood loss was observed a few months after insertion.
...
PMID:Bleeding patterns and clinical performance of the levonorgestrel-releasing intrauterine system (Mirena) up to two years. 1192 15

35 predominantly multiparous, sexually active women aged 25-44 years were fitted with levonorgestrel 20 T (Schering) IUDS in the post- menstrual phase, or in rare instances, right after abortion. the devices contained 60 mg of levonorgestrel releasing 20 mcg/day with the life span of 5 years. The patients were followed up every 3-6 months to detect side effects and complications. The first year contained a total of 339 months of observation, while the figure rose to 461 months in the second year. Spotting lasting 15-20 days followed insertion, but in later months only 7% of patients complained of bleeding or menstrual spotting. 7-8% of cases tended to have oligomenorrhea in the first year; 1/3 to 1/2 of them had hypomenorrhea during the first and second year. True amenorrhea started in 20-30% of women, persisting through both years. Longer duration of flow occurred in 32.4-4.57.1% of cases during these 2 years. Hormonal effects (headache, acne, hirsutism, depression, mastalgia, and inflamed varicose veins) ranged from 18.2- 33.3%. Levonorgestrel 20 T demonstrated more superior contraceptive efficacy than Progestasert; however, serious menstrual cycle disorders associated with it also increased. All progestin-releasing devices (the minipill, Norplant, Progestasert) induced menstrual changes, thus their use is preferable for therapeutic indications such as hypermenorrhea and uterine fibroid.
...
PMID:[Two-year clinical performance of the Levonorgestrel 20 T IUD]. 1231 72