Query: UMLS:C0268318 (
ICP
)
10,007
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
The concentration of As, Cr and Ni and their speciation (As3+;5+, Cr3+;6+ and Ni0;2+) in milled coal, bottom ash and ash collected by electrostatic precipitator (ESP) from a coal fired-power plant in western Canada were determined using HGAAS,
ICP
-AES and XANES. The chemical fractionation of these elements was also determined by a sequential leaching procedure, using deionized water, NH4OAC and
HCI
as extracting agents. The leachate was analyzed by
ICP
-AES. Arsenic in the milled coal is mostly associated with organic matter, and 67% of this arsenic is removed by ammonium acetate. This element is totally removed from milled coal after extraction with
HCI
. Arsenic occurs in both the As3+ and the As5+ oxidation states in the milled coal, while virtually all (>90%) of the arsenic in bottom ash and fly ash appears to be in the less toxic arsenate (As5+) form. Both Ni and Cr in the milled coal are extracted by
HCI
, indicating that water can mobilize Ni and Cr in an acidic environment. The chromium is leached by water from fly ash as a result of the high pH of the water, which is induced during the leaching. Ammonium acetate removes Ni from bottom ash through an ion exchange process. Chromium in milled coal is present entirely as Cr3+, which is an essential human trace nutrient. The Cr speciation in bottom ash is a more accentuated version of the milled coal and consists mostly of the Cr3+ species. Chromium in fly ash is mostly Cr3+, with significant contamination by stainless-steel from the installation itself.
...
PMID:Monitoring the species of arsenic, chromium and nickel in milled coal, bottom ash and fly ash from a pulverized coal-fired power plant in western Canada. 1125 1
Inductively coupled plasma atomic emission spectrometry (ICP-AES) is rapidly overtaking atomic absorption spectrometry (AAS) as the method of choice for the determination of toxic metals in workplace air. However, the few
ICP
-AES methods that have been published are not well characterised in terms of the effectiveness of the sample dissolution procedures described and their validation status. The International Standards Organization (ISO) is currently engaged in developing ISO 15202, which will describe a generic method for the determination of metals and metalloids in airborne particulate matter by
ICP
-AES. One part of the proposed standard deals with dissolution procedures. The ISO work has been supported by a project carried out in the authors' laboratory to identify, develop and validate sample dissolution procedures for inclusion in the proposed standard. This paper describes an interlaboratory comparison carried out to assess the performance of selected procedures using samples of airborne particulate matter collected on filters with a multiport sampler. Five dissolution procedures were tested. These included an ultrasonic agitation procedure, two hot-plate procedures (based upon NIOSH 7300 and OSHA ID 125G) and two microwave-assisted procedures (based upon
EPA
3052). It was shown that the dissolution procedures selected for use in the trial and used internally at HSL generally gave equivalent performance. As expected, a wider spread of results was obtained by participants in the trial. More specifically, there exists some reservation regarding the ability of the ultrasonic and hot-plate procedures to attack fully on a consistent basis some resistant materials, e.g., chromium containing particulate matter. Above all, the trial demonstrated the usefulness of microwave-assisted dissolution procedures in a modern laboratory.
...
PMID:Development of an international standard for the determination of metals and metalloids in workplace air using ICP-AES: evaluation of sample dissolution procedures through an interlaboratory trial. 1152 75
Inductively coupled plasma mass spectrometry (
ICP
/MS) with direct injection nebulization (DIN) was used to evaluate novel impinger solution compositions capable of capturing elemental mercury (Hg0) in
EPA
Method 5 type sampling. An iodine based impinger solution proved to be very efficient for Hg0 capture and was amenable to direct analysis by DIN-
ICP
/MS. Hg0 capture efficiency using aqueous iodine (I3-) was comparable to Hg0 capture using acidified potassium permanganate impinger solutions which were analyzed by cold vapor atomic absorption spectrometry (CVAAS), with greater than 98% capture of Hg0 in the first oxidizing impinger. Using DIN-
ICP
/MS, it was demonstrated for the first time that iodine can be generated just prior to impinger sampling for efficiently oxidizing Hg0 and retaining it in solution as HgI4(2-). Due to the increased interest in Hg speciation from combustion sources and the potential for using DIN-
ICP
/MS for multiple metals analyses, an impinger sampling train for gaseous Hg speciation and multiple metals analyses using DIN-
ICP
/MS analyses is presented. The unique feature of such a sampling train is that each impinger solution in the series is amenable to direct analysis by DIN-
ICP
/MS. A bituminous coal was combusted in a bench scale coal system, and gaseous Hg species (oxidized and elemental) were determined using the proposed impinger train. The DIN-
ICP
/MS instrumental detection limit was 0.003 ppb, and MDLs ranged from 0.007 to 0.116 microg/L (ppb) in a variety of impinger solutions used for Hg capture.
...
PMID:The development of iodine based impinger solutions for the efficient capture of Hg0 using direct injection nebulization-inductively coupled plasma mass spectrometry analysis. 1178 57
Soluble species of phosphorus, sulfur, selenium and eight metals (Mn, Fe, Co, Ni, Cu, Zn, Mo and Cd) in soybean flour and common white bean seeds were investigated by size exclusion chromatography (SEC) and inductively coupled plasma mass spectrometry (ICP-MS). Samples were extracted by 0.02 mol l(-1) Tris-
HCI
buffer solution (pH 7.5). Fractionation of sample extracts by preparative scale SEC was accomplished using a Fractogel EMD BioSEC column (600 x 16 mm) and 0.02 mol l(-1) Tris-HCl buffer solution (pH 7.5) as mobile phase (flow rate: 2 ml min(-1)). A 2-ml sample was injected. Contents of elements in chromatographic fractions were determined by AAS,
ICP
-AES and
ICP
-MS. The elution profiles of P, Fe, Co, Ni, Cu, Zn and Mo in both samples were similar. Main species of Co, Ni, Cu, Zn and Mo were found in the low molecular weight region (2-5 kDa), whereas Fe is predominantly bound to high molecular weight compounds (180 kDa). The dominant phosphorus fraction was detected in the medium molecular weight region (10-30 kDa) and the other fraction in the low molecular weight region. Isotachophoretic analysis of chromatographic fractions revealed that the main phosphorus compound in the medium molecular weight region is phytic acid. SEC on Superdex 75 and Superdex Peptide columns (300 x 10 mm) was performed in on-line hyphenation with
ICP
-MS. The same mobile phase was used with a flow rate of 0.5 ml min(-1); volume of injected sample was 200 microl. Element specific chromatograms were obtained by continuous nebulization of effluent into
ICP
-mass spectrometer measuring intensities of 47(PO)+ and 48(SO)+ oxide ions and 55Mn, 57Fe, 59Co, 62Ni, 65Cu, 66Zn, 82Se, 95Mo and 114Cd nuclides. Chromatographic profiles of elements are generally analogous to those obtained with a Fractogel column, but better chromatographic resolution of separated species was achieved so that slight differences between samples were revealed. Estimated molecular weights of major phosphorus species in soybean flour and common white bean seed extracts are 6 and 3.6 kDa, respectively, whereas those of minor phosphorus species in both samples are 0.7 kDa. Traces of phosphorus were also detected in the high molecular weight region (130 kDa). Chromatograms of P, Ni, Cu, Zn and Mo compounds in both extracts are similar but not identical. Molecular weights of major Cu and Zn species are approximately 1 and 0.4 kDa for soybean flour and white bean seeds, respectively. In cases of Mn, Fe, Co and Se, the element profiles of soybean flour and white bean seed extracts are significantly different.
...
PMID:Fractionation of phosphorus and trace elements species in soybean flour and common white bean seeds by size exclusion chromatography-inductively coupled plasma mass spectrometry. 1201 35
The objective of the work carried out was to recommend protocols for the collection, filtration (0.45 microm) and preservation of surface water samples for the subsequent determination of total 'dissolved' Hg. Cold vapour (CV)
ICP
-MS was employed to determine Hg; samples were acidified to a strength of 4 mol l(-1) HCl and 1% NaBH4 was used as the reducing agent in-line. Four types of 125 ml bottles were studied (Teflon, fluorinated ethene propene copolymer, FEP; high density polyethylene, HDPE; polyethylene terephthalate copolyester, PET; polypropylene, PP), together with three cleaning methods (
EPA
Methods 1631, 1638 and a rinse with reverse osmosis deionised water, 'MilliQ'). The transmission properties of the four materials were also studied to evaluate the potential for contamination from atmospheric Hg0. Results of this bottle study (n = 195), all below the detection limit of 0.5 ng l(-1), indicate that the bottles of choice, from an economic and time-saving perspective, are HDPE and PP, the latter being preferable if the sample is to be stored in a contaminated atmosphere. The bottles would be used on a once-only basis, negating the need for labourious and costly cleaning on repeat use. A simple rinse with MilliQ water would suffice prior to use. Twelve 0.45 microm filter systems (mostly Millipore and Gelman) were studied for (a) their potential Hg contamination properties and (b) their retention of Hg, possibly in colloidal form, during filtration. Ottawa River water, spiked at 50 ng l(-1) Hg, was used as a control sample. Again blank values were all negative, indicating contamination was not a concern but different recoveries of Hg were obtained across the different systems. The optimum systems to use, in that they provided maximum recovery (ca 80%) of Hg, are the Millipore Sterivex capsule and the Millipore Millex disc, both based on the hydrophilic Durapore membrane. The lowest recoveries (23-36%) were found with the Gelman AquaPrep systems and the Millipore HN nylon filter. Four control samples, Ottawa, Rideau and Gatineau Rivers, and a MilliQ blank, were used to study three preservation approaches, in the media: 0.5% BrCl, 2% HCl and 0.04% K2Cr2O7 in 1% HNO3. Mercury was stable for 28 days in a medium of 0.5% BrCl in all four samples but the other two media showed a loss of up to ca 20% Hg over this time frame, the loss being sample and time dependent. This may be a species transformation which is not detected by CV-
ICP
-MS from an HCl medium but this requires further investigation. Mercury was stable over the 28 days in the spiked blank MilliQ sample for all three preservation media.
...
PMID:Sample collection, filtration and preservation protocols for the determination of 'total dissolved' mercury in waters. 1208 Oct 47
Regulating arsenic species in drinking waters is a reasonable objective, since the various species have different toxicological impacts. However, developing robust and sensitive speciation methods is mandatory prior to any such regulations. Numerous arsenic speciation publications exist, but the question of robustness or ruggedness for a regulatory method has not been fully explored. The present work illustrates the use of anion exchange chromatography coupled to
ICP
-MS with a commercially available "speciation kit" option. The mobile phase containing 2 mM NaH(2)PO(4) and 0.2 mM EDTA at pH 6 allowed adequate separation of four As species (As(III), As(V), MMAA, DMAA) in less than 10 min. The analytical performance characteristics studied, including method detection limits (lower than 100 ng L(-1) for all the species evaluated), proved the suitability of the method to fulfill the current regulation. Other parameters evaluated such as laboratory fortified blanks, spiked recoveries, and reproducibility over a certain period of time produced adequate results. The samples analyzed were taken from water utilities in different areas of the United States and were provided by the U.S.
EPA
. The data suggests the speciation setup performs to U.S.
EPA
specifications but sample treatment and chemistry are also important factors for achieving good recoveries for samples spiked with As(III) as arsenite and As(V) as arsenate.
...
PMID:A study of method robustness for arsenic speciation in drinking water samples by anion exchange HPLC-ICP-MS. 1218 80
Eighteen Dutch soils were extracted in aqueous solutions at varying pH. Extracts were analyzed for Cd, Cu, Ni, Pb and Zn by
ICP
-AES. Extract dissolved organic carbon (DOC) was also concentrated onto a macroreticular resin and fractionation into three operationally defined fractions: hydrophilic acids (Hyd), humic acids (HA) and fulvic acids (FA). In this manner, change in absolute solution concentration and relative percentage for each fraction could be calculated as a function of extraction equilibrium pH. The soils were also analyzed for solid phase total organic carbon and total recoverable metals (
EPA
Method 3051). Partitioning coefficients were calculated for the metals and organic carbon (OC) based on solid phase concentrations (less the metal or OC removed by the extraction) divided by solution concentrations. Cu and Pb concentrations in solution as a function of extract equilibrium pH are greatest at low and high pH resulting in parabolic desorption/dissolution curves. While processes such as proton competition and proton promoted dissolution can account for high solution metal concentrations at low pH, these processes cannot account for higher Cu and Pb concentrations at high pH. DOC increases with increasing pH, concurrently with the increase in Cu and Pb solution concentrations. While the absolute concentrations of FA and HA generally increase with increasing pH, the relative proportional increase is greatest for HA . Variation in HA concentrations spans three orders of magnitude while FA concentrations vary an order of magnitude over the pH range examined. Correlation analysis strongly suggests that HA plays a major role in increasing the concentration of solution Cu and Pb with increasing pH in the 18 soils studied. The percentage of the OC that was due to FA was nearly constant over a wide pH range although the FA concentration increased with increasing pH and its concentration was greater than that of the HA fraction at lower pH values (pH = 3-5). Thus, in more acidic environments, FA may play a larger role than HA in governing organo-metallic interactions. For Cd, Ni, and Zn, the desorption/dissolution pattern shows high metal solution concentrations at low pH with slight increases in solution concentrations at extremely high pH values (pH>10). The results presented here suggest that the effects of dissolved organic carbon on the mobilization of Cd, Ni, and Zn may only occur in systems governed by very high pH. At high pH, it is difficult to distinguish in this study whether the slightly increased solution-phase concentrations of these cations is due to DOC or hydrolysis reactions. These high pH environments would rarely occur in natural settings.
...
PMID:Correlation of the partitioning of dissolved organic matter fractions with the desorption of Cd, Cu, Ni, Pb and Zn from 18 Dutch soils. 1243 90
Inductively coupled plasma-mass spectrometry (ICP-MS) method
EPA
200.8 is gradually finding acceptance as an alternative to uranium analysis. A comparison of the
ICP
-MS with the accepted radiochemical method
EPA
908.0 has been carried out based on data from laboratory control standards, national proficiency test samples, and environmental and drinking water samples from the State of Utah. The method detection limit (MDL) for
ICP
-MS was determined to be 0.017 microg/L or (0.011 pCi/L), and the minimum reporting limit (MRL) was 0.17 microg/L (MDL x 10) or (0.11 pCi/L). The minimum reporting limit for radiochemical 908.0 method is 1 pCi/L. Our spiked matrix recoveries, spiked blank samples, and reference materials deviate only a few percentage from the listed true values. Results demonstrate that the
ICP
-MS is a superior analytical tool for the determination of uranium in drinking and environmental waters at concentrations required by the United States Environmental Protection Agency.
...
PMID:Comparison of inductively coupled plasma-mass spectrometry and radiochemical techniques for total uranium in environmental water samples. 1252 Nov 66
A validation study was carried out in order to evaluate the efficiency of inductively coupled plasma-optical emission spectrometry (ICP-OES) for the analysis of minor elements (manganese, chromium, copper, iron, and titanium) in aluminium alloys. Aluminium casting samples were obtained by adding compressed powder compacts of each alloying element and aluminium (minitablets) to aluminum baths in a laboratory crucible furnace. Digestion of solid samples was performed using concentrated
HCI
and H202 35% (v/v) previous to analysis by
ICP
-OES without any matrix separation. This solution-based method was validated considering direct current arc spectrometry as the reference method based on direct analysis without any pretreatment of the solid samples considered. Univariate statistical procedures were carried out, for which precision <3% and trueness of the analytical results were taken into account.
...
PMID:Inductively coupled plasma compared with direct current arc spectrometry for analysis of minor elements in aluminium baths. 1549 81
Coal as well as fuel oil combustion generates emissions of potentially toxic trace pollutants including organic and inorganic chemical compounds besides major pollutants. A study on As, Cd, Co, Cr, Cu, Hg, Fe, Mn, Ni, Pb, Se, and Zn emissions from a 220 MW coal-fired power plant equipped with a electrostatic precipitators (ESPs) and 6 MW oil fired-power plant was carried out, using stack monitoring kit, Envirotech APM 620, which is similar to
EPA
Method 29. Simultaneous sampling of coal, fuel oil, oil waste, bottom ash, fly ash, flue gases, and particles associated with the gas phase has been performed. This sampling method was used for trace metal sampling. The content of all these metals in coal, oil, oil waste, bottom ash, fly ash have been determined by XRF, whereas their contents in the flue gases, and particles associated with the gas phase has been analyzed with
ICP
-AES. The mass balances obtained for trace elements were satisfactory in case of fuel oil based power plant, whereas in case of coal fired power plant, the mass balance for all the trace elements were below 50% except for the As, Se, and Hg. The enrichment factors for all trace metals was <1 in both cases. The above sampling method is moderately adequate method for trace element sampling in coal as well as oil fired power plants except for Hg. The results indicate that trace metals emissions were higher in coal-based power plant than the fuel oil-fired power plant.
...
PMID:Evaluation of the emission characteristics of trace metals from coal and fuel oil fired power plants and their fate during combustion. 1591 50