Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0268318 (ICP)
10,007 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

The argon supported inductively coupled plasma--atomic emission spectrometer (ICP--AES) is found to be an attractive analytical tool for the simultaneous multi-element determination of major, minor and trace elements in human liver and kidney specimens. The sample is digested with a mixture of HNO3--HClO4. The damp residue is taken up in HCl, aspirated into the plasma and the resulting emission signals are detected by a polychromator where the analytical lines of the 20 elements determined are included as fixed channels. The method is rapid, precise, sensitive, less subject to interferences and cost-effective. A total of 20 elements in about 40 autopsy samples of human kidney (cortex and medulla) and liver taken from Canadian adults living in the Great Lakes Region of Ontario were determined using the wet digestion-ICP--AES technique.
...
PMID:Simultaneous determination of 20 elements in some human kidney and liver autopsy samples by inductively-coupled plasma atomic emission spectrometry. 711 97

Various canned foods were digested sequentially with HNO3 and HCl, diluted to 100 mL, and filtered, and then tin was determined by inductively coupled plasma atomic emission spectrometry (ICP/AES). Samples of canned Satsuma mandarin, peach, apricot, pineapple, apple juice, mushroom, asparagus, evaporated milk, short-necked clam, spinach, whole tomato, meat, and salmon were evaluated. Sample preparations did not require time-consuming dilutions, because ICP/AES has wide dynamic range. The standard addition method was used to determine tin concentration. Accuracy of the method was tested by analyzing analytical standards containing tin at 2 levels (50 and 250 micrograms/g). The amounts of tin found for the 50 and 250 micrograms/g levels were 50.5 and 256 micrograms/g, respectively, and the repeatability coefficients of variation were 4.0 and 3.8%, respectively. Recovery of tin from 13 canned foods spiked at 2 levels (50 and 250 micrograms/g) ranged from 93.9 to 109.4%, with a mean of 99.2%. The quantitation limit for tin standard solution was about 0.5 microgram/g.
...
PMID:Inductively coupled plasma atomic emission spectrometric determination of tin in canned food. 828 77

All the lanthanide elements (REE) in fern (Matteuccia) and in soil were determined with inductively coupled plasma mass spectrometer (ICP-MS) in order to discuss REE behavior in fern. The fern sample was divided into three parts: root, stem, and leaf; the soil of the same site was also sampled and the soil sample was divided into two parts: HCl and HNO3 soluble part (soil[HCl]) and HF soluble part (soil[HF]). REE in each part was determined by ICP-MS after solvent extraction separation. The overall variation of the REE pattern of the root does not resemble that of the whole soil, but that of the HF soluble part. A tetrad effect variation (W-type) was found in the REE patterns of root, stem and leaf; more conspicuous tetrad effect variation was observed in HREE region than in LREE region, and was so in stem and leaf than in root. Negative anomalies of Ce were observed in the REE patterns of root, stem and leaf, with bigger anomalies in stem and leaf than in root. The results of this study suggest that REE in fern has come from silicates of soil and has once been in dissolved state.
...
PMID:Distribution pattern of rare earth elements in fern: implication for intake of fresh silicate particles by plants. 984 59

Aluminium speciation was studied in forest soil extracts by size exclusion chromatography (SE) with UV and inductively coupled plasma-atomic emission spectrometric (ICP-AES) detection and cation exchange fast protein liquid chromatography (FPLC) with ETAAS detection. Size exclusion chromatography was performed on a Superdex HR75 10/30 column. Isocratic clution with 0.15 mol dm(-3) NaCl in TRIS-HCl buffer (pH = 5.5) was applied over 100 min at a flow rate of 0.35 cm(3) min(-1). The chromatographic run was followed at 278 nm and separated Al species also determined 'off line' in 0.875 cm3 fractions by ICP-AES. The analytical procedure enabled speciation of high molecular weight Al complexes. Cation exchange FPLC was performed on a Mono S HR 5/5 column. Aqueous 8 mol dm(-3) NH4NO3 linear gradient elution was applied over 10 min at a flow rate of 1 cm3 min(-1). Separated Al species were collected in 0.5 cm3 fractions and Al determined 'off line' by ETAAS. The analytical procedure enabled speciation of some positively charged monomeric Al species. Negatively charged species were eluted with the solvent front. The combination of the two analytical techniques was successfully employed in speciation of Al in forest soil extracts. Water was used as an extracting solution. It was found experimentally that 80-95% of Al in aqueous extracts of forest soils exists in monomeric Al forms. Water soluble Al (30-40%) is bound to high molecular weight complexes with humic substances. The remaining monomeric Al in the low molecular weight fraction exists as AIF2+, Al-oxalate and Al-citrate species.
...
PMID:Speciation of aluminium in forest soil extracts by size exclusion chromatography with UV and ICP-AES detection and cation exchange fast protein liquid chromatography with ETAAS detection. 1100 89

A simple and reliable extraction method was developed for quantitative determination of both butyl- and phenyltin compounds in sediments by capillary gas chromatography combined with inductively coupled plasma mass spectrometry (GC-ICP-MS). Both types of organotin compounds were extracted quantitatively from sediment by mechanical shaking into tropolone-toluene and HCl-methanol. After phase separation and pH adjustment, these organotins were ethylated with sodium tetraethylborate. The method was evaluated by analyzing PACS-2 and NIES No. 12 sediment certified reference materials. The dibutyltin (DBT; 1.14 +/- 0.02 micrograms g-1) and tributyltin (TBT; 1.01 +/- 0.04 micrograms g-1) values observed in PACS-2 sediment closely matched the certified values (DBT, 1.09 +/- 0.15; TBT, 0.98 +/- 0.13 microgram g-1 as tin). The monobutyltin (MBT) value was higher (0.62 +/- 0.02 microgram g-1) by more than two fold over the reference value (0.3 microgram g-1 as tin). The concentrations of TBT (0.18 +/- 0.04 microgram g-1) and triphenyltin (TPhT; 0.0099 +/- 0.002 microgram g-1) in the NIES No. 12 sediment were also in good agreement with the certified and reference values of TBT (0.19 +/- 0.03 microgram g-1 as compound) and TPhT (0.008 microgram g-1 as compound), respectively. Recoveries of TBT, tripentyltin (TPeT) and TPhT from spiked sediments were satisfactory (TBT, 102 +/- 3.4%; TPrT, 96 +/- 3.4%; TPhT, 99 +/- 8.5%). The detection limits as tin were in the range 0.23-0.48 ng g-1 for a 0.5 g sample size. It is also noteworthy that clean-up of the extract is not necessary because of the superior selectivity of ICP-MS detection. The present method was successfully applied to marine sediment samples.
...
PMID:A quantitative extraction method for the determination of trace amounts of both butyl- and phenyltin compounds in sediments by gas chromatography-inductively coupled plasma mass spectrometry. 1107 May 44

An imidazoline group-containing chelating fiber was prepared by means of the reaction of nitrile groups with ethylenediamine in an hydrazine-modified polyacrylonitrile fiber. The adsorption properties of the chelating fiber for Au(III), Pd(II), Pt(IV), Ir(IV), Os(IV), Rh(III) and Ru(IV) ions, such as binding capacity, distribution coefficient, sorptive rate and quantitative elution of Au(III), Pd(II) and Pt(IV) ions were investigated. The imidazoline group-containing chelating fiber possessed high binding capacities and good adsorption kinetic properties, exhibited high affinity for noble metals in 0.1-1.0 mol/L HCl and could be efficiently re-used. After the separation of trace Au(III), Pd(II) and Pt(IV) ions from a matrix using the chelating fiber, these ions could be determined by ICP-AES with satisfactory results, and the relative standard deviation for Au(III), Pd(II) and Pt(IV) ions was less than 6%.
...
PMID:Application of an imidazoline group-containing chelating fiber for the determination of trace noble metals in superhigh-temperature alloys. 1122 15

The increasing emission of Pt-group metals from automobile catalytic converters requires the development of highly sensitive procedures for ultratrace analysis of environmental and biological systems. Tree bark, located close to motorway or industrial areas, was utilised as a substrate for collection of airborne particulate matter and samples after digestion (microwave assisted dissolution with HNO3 and HCl) were analysed by ICP mass spectrometry. The study targeted Pt and other metallic contaminants and involved analysis of some 57 tree bark samples using both quadrupole and double-focusing sector field ICP mass spectrometers. Detection limits for platinum determination in tree bark were 0.03 ng/g (DF-ICP-MS) and 0.2 ng/g (ICP-QMS). The platinum content of the bark samples ranged from 0.07-5.4 ng/g.
...
PMID:Determination of trace elements including platinum in tree bark by ICP mass spectrometry. 1122 31

Application of microwave assisted extraction for the decomposition and dissolution of plant samples for trace metal determination by ICP-AES was examined. Dried onion, leaves of spinach beet and three reference materials CTA-OTL-1, CTA-VTL-2 and CL-1 were analyzed. Water, EDTA and hydrochloric acid (0.01, 0.10 and 1.0 M, respectively) were used as leaching solutions. The extraction efficiency was investigated by comparison of the results with those obtained after microwave wet digestion. HCl was found to be very suitable for quantitative extraction of B, Ba, Cd, Cu, Mn, Ni, Pb, Sr and Zn from the samples. For reference materials, the measured concentrations are well consistent with the certified values. The use of EDTA led to a complete extraction of B, Cd, Ni, Pb, Sr and Zn. Water was found to be a good leaching solution for boron. For extraction with HCl and EDTA, the RSD values for the concentrations measured were below 8% for most of the elements.
...
PMID:Microwave assisted extraction for trace element analysis of plant materials by ICP-AES. 1122 16

A new method using nanoparticle TiO2 as solid-phase extractant coupled with ICP-AES was proposed for simultaneous determination of trace elements. The adsorption behavior of nanometer TiO2 towards Cu, Cr, Mn and Ni was investigated by ICP-AES, and the adsorption pH curves, adsorption isotherms and adsorption capacities were obtained. It was found that the adsorption rates of the metal ions studied were more than 90% in pH 8.0-9.0, and 2.0 mol L-1 HCl was sufficient for complete elution. Nanometer TiO2 possesses a significant capacity for the sorption of the metal ions studied which is higher than the capacity of silica, the commonly used extractant. The method has been applied to the analysis of some environmental samples with satisfactory results.
...
PMID:Study of the adsorption behavior of heavy metal ions on nanometer-size titanium dioxide with ICP-AES. 1122 17

In the field of industrial hygiene, besides the necessity of monitoring phosphine with direct reading apparatus to prevent accidents, there is a need for a method of sampling and analysing phosphine to control workers' exposure. The use of filters impregnated with silver nitrate to collect arsine, phosphine and stibine in workplace air has been described in the literature. Having previously chosen this type of filter to collect arsine, we studied its characteristics for phosphine capture. A filter impregnated with sodium carbonate was used both as a prefilter to collect the particles and to trap arsenic trioxide. After dissolving the silver compounds in nitric acid, ICP emission spectrometry was used to carry out the analysis. This article describes the comparative sampling we performed in a microelectronic laboratory and in a fumigation chamber (130 samples) to determine the concentration of AgNO3 impregnation solution to be used, the detection limit of the method and the retention capacity of the impregnated filters. Interference with other gases reacting with silver nitrate was studied and the storage time for sampled filters and analysis solutions was checked. The detection limit of the adopted method is better than 1 microg per filter, and the retention capacity exceeds 300 microg per filter. The problem of how to sample phosphine when H2S, NH3, or HCl is present has been solved, but the problem of sampling phosphine in atmospheres where acetylene evolves remains. Sampled filters and filter solutions are stable for more than three months at ambient temperature.
...
PMID:Phosphine sampling and analysis using silver nitrate impregnated filters. 1125 53


1 2 3 4 5 6 7 8 9 10 Next >>