Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0268318 (
ICP
)
10,007
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
The features of different nebulizer systems (cross-flow-, Meinhard- and GMK-system) in the
ICP
atomic emission spectrometric analyses of solutions with different contents of different salts were evaluated. As basis for the comparison of the nebulizer systems the recovery rates and noise power spectra were used. Both showed that the GMK-system could be used for the widest diversity of salts (sodium chloride, ammonium sulfate and sodium tetraborate) and concentration range (0-10%, (m/v)) followed by the cross-flow-system and the Meinhard-system in
ICP
-OES using a 1 kW argon
ICP
. Of all nebulizer systems the nebulizer according to Meinhard has the lowest performance for the salts investigated. The noise power spectra of all nebulizer systems are dominated by interference noise from the sample introduction system. This noise increases with the
salt
concentration of the solution and the GMK-system shows the lowest increase, followed by the cross-flow- and Meinhard-system.
...
PMID:Noise power spectra and recovery rates obtained with different nebulizer systems in ICP atomic emission spectrometric analyses in the case of different types of salts and salt contents. 1122 May 73
A possible steady state kinetic model is presented for the atomization and excitation processes during inductively coupled plasma atomic emission spectrometry. The model takes into account the relative rates of (a) thermal dissociation of analyte
salt
, (b) recombination of counter atom and analyte atoms, (c) charge transfer between analyte and interferent species, (d) charge transfer between analyte and argon species, and (e) ion/electron collisional de-ionization. Number density ratio data, n(u)'/n(u), where n(u) denotes the excited state and the prime denotes the presence of an interferent element, are presented showing that the predictions of the model are consistent with the signal enhancement observed at low analyte concentrations when Ca is determined by
ICP
in the presence of excess Li.
...
PMID:A possible steady state kinetic model for the atomization and excitation processes during inductively coupled plasma atomic emission spectrometry: application to interference effects of lithium on calcium. 1122 Aug 30
Newly developed methods involving an on-line combination of sedimentation field-flow fractionation-inductively coupled plasma-high resolution mass spectrometry (SdFFF-ICP-HRMS) have been used to study the distributions of extractable heavy metals in a soil which had been treated with sewage sludge contaminated with Cu or Pb. The relationship of these metals with other elements in the colloidal fraction was also investigated. The colloidal fraction from the soil was obtained by repeated gravitational sedimentation and extracted with 0.11 M acetic acid, 0.1 M hydroxylamine hydrochloride, 0.05 M ethylenediaminetetraacetic acid disodium
salt
(EDTA) or aqua regia to assess the potential availability of the metals Cu and Pb. Large proportions of the Cu and Pb were extracted by EDTA, approaching that removed by aqua regia, whereas < 10% of the aqua regia extractable metals were removed by acetic acid and hydroxylamine chloride. The distributions of the heavy metals, the major mineral forming element (Al) and the elements forming sesquioxides (Fe and Mn) within different size classes (0.05-1 microm) of the colloidal fraction were measured using SdFFF-
ICP
-HRMS before and after extraction with EDTA. This information provides an insight into the composition of the colloids and the distributions of metal contaminants. In the contaminated soil colloids, the concentration of Fe, Mn and Pb is greatest in the smaller particles (<0.2 microm). In contrast, the Cu concentration is constant over the size range studied. Iron oxide surface coatings probably play a significant role in Pb adsorption on soil particles, but may be less important for Cu. The combination of selective chemical extraction, SdFFF and
ICP
-HRMS provides a means of determining the distribution of potentially available heavy metals within the colloidal fraction of contaminated soils.
...
PMID:Determination of total and EDTA extractable metal distributions in the colloidal fraction of contaminated soils using SdFFF-ICP-HRMS. 1125 22
The cesium
salt
of the icosahedral borane anion dodecahydroxy-closo-dodecaborate(2-), Cs(2)[closo-B(12)(OH)(12)], Cs(2)1, was prepared by heating cesium dodecahydro-closo-dodecaborate(2-), Cs(2)[closo-B(12)H(12)], Cs(2)2, with 30% hydrogen peroxide. The other alkali metal salts A(2)1 (A = Li, Na, K, Rb) precipitated upon addition of ACl to warm aqueous solutions of Cs(2)1. The ammonium
salt
, [NH(4)](2)1, and the (mu-nitrido)bis(triphenylphosphonium)
salt
, [PPN](2)1, were obtained similarly. The [H(3)O](2)1
salt
precipitated upon acidification of aqueous solutions of Cs(2)1 with hydrochloric acid. The solubility of these salts in water was determined by measuring the boron content of saturated aqueous solutions of A(2)1 (A = Li, Na, K, Rb, Cs), [H(3)O](2)1, and [NH(4)](2)1 using
ICP
-AES. Although these salts are derived from a dianion with twelve pendant hydroxyl groups, the alkali metal salts surprisingly displayed low water solubilities. Water solubility decreases with a decrease in the radius of A(+), except for the lithium
salt
, which is slightly more soluble than the potassium
salt
. The [H(3)O](2)1 and the [NH(4)](2)1 salts provide rare examples of water-insoluble hydronium and ammonium salts. The low water solubility of the A(2)1 salts is attributed to the dianion's pendant hydroxyl groups, which appear to function as cross-linking ligands. Four alkali metal salts, A(2)1 (A = Na, K, Rb, Cs), were characterized in the solid state by single-crystal X-ray crystallography. These data revealed intricate networks in which several anions are complexed through their hydroxyl groups to each alkali metal cation. In addition, the anions are engaged in hydrogen bonding with each other and, if present, with water of hydration. This cross-linking results in the precipitation of aggregated salts. Cation coordination numbers decrease with cation radius. Thus, cesium and rubidium are ten-coordinate, whereas potassium is seven-coordinate and sodium is six-coordinate. The geometry of anion 1(2)(-) is independent of cation identity; the B-B and B-O bond lengths of the various A(2)1 salts (A = Na, K, Rb, Cs) are identical.
...
PMID:Dodecahydroxy-closo-dodecaborate(2-). 1145 63
Multidimensional (size-exclusion-anion-exchange-cation-exchange) liquid chromatography with
ICP
-MS detection was developed to produce a map of water-soluble species in an oyster test reference material. The presence of arsenobetaine, trimethyl(2-carboxyethyl)arsonium inner
salt
, arsenocholine, dimethylarsonic acid, tetramethylammonium ion, As(v) and two arsenosugars was demonstrated by ES-MS-MS. A previously unreported compound was isolated and identified by ES-MS-MS as 5-dimethylarsinoyl-beta-ribofuranose. Anion-exchange chromatography was optimized to produce a chromatographically pure peak of arsenobetaine (accounting for ca. 64% of all water-soluble As present) that was used to quantify this compound.
...
PMID:Investigation of arsenic speciation in oyster test reference material by multidimensional HPLC-ICP-MS and electrospray tandem mass spectrometry (ES-MS-MS). 1147 35
The presented colorimetric procedure only requires simple laboratory equipment and is suitable as a routine procedure for checking concentrations of iodine in fortified culinary products. The Moxon and Dixon colorimetric procedure for iodine determination has been optimised for the determination of iodide and iodate in fortified culinary products, always containing high
salt
levels. The high sensitivity of the method permits a high dilution of the product solutions, thus reducing interferences from the inherent colour of the products. The calibration is linear in the range from 0 to 12 microg L(-1) of iodine with R2 > 0.99. A series of commercial culinary products were used to validate the method. Recoveries of iodine, added as iodide and/or iodate, were generally in the range 100+/-10%. High concentrations of chloride are essential to obtain a complete recovery of iodate. Limit of quantification was estimated to be 2 mg kg(-1) of product, based on 2-3 g of product. Concentrations of iodine determined with this method were similar to those obtained by an
ICP
-MS procedure.
...
PMID:Colorimetric determination of inorganic iodine in fortified culinary products. 1147 60
The development and implementation of a method for the certification of cadmium in blood samples at low ng g(-1) and sub ng g(-1) levels is described. The analytical procedure is based on inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) applied as a primary method of measurement. Two different sample digestion methods, an optimized microwave digestion procedure using HNO3 and H2O2 as oxidizing agents and a high-pressure asher digestion procedure, were developed and compared. The very high
salt
content of the digests and the high molybdenum content, which can cause oxide-based interferences with the Cd isotopes, were reduced by a chromatographic matrix separation step using an anion-exchange resin. All isotope ratio measurements were performed by a quadrupole
ICP
-MS equipped with an ultrasonic nebulizer with membrane desolvator. This sample introduction set-up was used to increase sensitivity and minimize the formation of oxides (less MoO+ interference with the Cd isotopes). Because of the very low Cd concentrations in the samples and the resulting need to minimize the procedural blank as much as possible, all sample-processing steps were performed in a clean room environment. Detection limits of 0.005 ng g(-1) Cd were achieved using sample weights of 2.7 g. The method described was used to recertify the cadmium content of three different blood reference materials from the Community Bureau of Reference (BCR) of the European Commission (BCR-194, BCR-195, BCR- 196). Cadmium concentrations ranged between approximately 0.2 ng g(-1) and approximately 12 ng g(-1). For these materials, SI-traceable certified values including total uncertainty budgets according to ISO and Eurachem guidelines were established.
...
PMID:SI-traceable certification of the amount content of cadium below the ng g(-1) level in blood samples by isotope dilution ICP-MS applied as a primary method of measurement. 1149 77
Numerous etiological studies have established a positive clinical association between hypertension and erectile dysfunction. However, to date, the mechanism underlying this dysfunction remains to be established. In this study, we demonstrate the presence of erectile dysfunction in two rat models of hypertension, and hypothesize that increased vasoconstrictor signaling via Rho-kinase contributes to the decreased erectile response. We found deoxycorticosterone-
salt
and stroke prone-spontaneously hypertensive rats to exhibit a decreased erectile response, recorded as intracavernosal pressure/mean arterial pressure (
ICP
/MAP) upon electrical stimulation of the major pelvic ganglion. As previously shown, inhibition of Rho-kinase activity by intracavernosal injection of the selective inhibitor, Y-27632, resulted in an increase in
ICP
/MAP. However, Y-27632 was significantly less effective at increasing
ICP
/MAP in the hypertensive as compared to normotensive rats. Additionally, intracavernosal injection of Y-27632 potentiated the voltage-stimulated increase in
ICP
/MAP in both hypertensive and normotensive rats, but was less effective at potentiating the voltage-mediated erectile response in the hypertensive rats. Altogether, our data demonstrate a decreased erectile response in a mineralocorticoid and genetic model of hypertension, and suggest the role of increased cell signaling by Rho-kinase in the vasoconstrictor activity of erectile dysfunction associated with hypertension.
...
PMID:Decreased penile erection in DOCA-salt and stroke prone-spontaneously hypertensive rats. 1178 42
Biogenic (e.g. phytochelatins, porphyrins, DOM) as well as anthropogenic (e.g. NTA, EDTA, phosphonates) chelators affect the mobility and cycling of heavy metals in environmental waters. Since such chelators can form strongly bound anionic heavy metal complexes that are stable and highly mobile, anion-exchange chromatography coupled to
ICP
-MS was investigated. A narrow bore HPLC system was connected to a micro concentric nebuliser for in-line sample introduction. A new chromatographic procedure based on a synthetic hydrophilic quaternary ammonium anion exchanger in combination with nitrate as a strong eluent anion, and gradient elution, provided high separation selectivity and a large analytical window. Low detection limits (nmol L(-1)) were achieved by on-column matrix removal and sample preconcentration. This allowed the method to be successfully applied to different environmental research areas. In ecotoxicological studies of heavy metal effects on algae low concentrations of metal EDTA complexes were determined in nutrient solutions without interference from high (buffer)
salt
concentrations. In groundwater, infiltrated by a polluted river, mobile metal EDTA species were observed. In river water of different pollution levels beside CuEDTA other anionic Cu-complexes were found in nmol L(-1) concentrations.
...
PMID:Speciation of heavy metals in environmental water by ion chromatography coupled to ICP-MS. 1193 32
A simple and rapid procedure, utilising constant-current stripping analysis (CCSA) at a carbon-paste electrode containing tricresyl phosphate as a pasting liquid (TCP-CPE), has been developed for the determination of iodide in table
salt
. Because of a synergistic accumulation mechanism based on ion-pairing and extraction of iodide in combination with electrolytic pretreatment of the TCP-CPE, the method is selective for iodide and enables direct determination of iodide in samples of table
salt
containing anti-caking agents such as K(4)[Fe(CN)(6)] (food additive "E 536") or MgO. The iodide content (calculated as KI) can be determined in a concentration range of 2 to 100 mg kg(-1)
salt
, with a detection limit (S/N=3) of 1 mg kg(-1), and a recovery from 90 to 115%. The proposed method has been used to determine iodide in several types of artificially iodised table
salt
and in one sample of natural sea
salt
. The results obtained agreed well with those obtained by use of three independent reference methods (titration, spectrophotometry, and
ICP
-MS) used to validate the CCSA method, indicating that the developed method is applicable as a routine procedure for rapid testing in
salt
production process control and in the analysis of marketed table salts.
...
PMID:Simple and rapid determination of iodide in table salt by stripping potentiometry at a carbon-paste electrode. 1201 91
<< Previous
1
2
3
4
5
6
7
8
9
10
Next >>