Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0268318 (
ICP
)
10,007
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
This work evaluates cocaine purity and the concentration ranges of adulterants and inorganic constituents for 31 street cocaine samples seized in two different regions of Brazil from July 2008 to May 2010. Cocaine and adulterants, such as
caffeine
, lidocaine and benzocaine, were quantified by Gas chromatography-mass spectrometry (GC-MS), and the inorganic constituents were determined by Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES) and ion chromatography (IC). The cocaine concentrations in the samples seized in the Amazonas state (AM samples) ranged from 154 to 978mgg(-1), and these samples did not contain any of the adulterants studied. The cocaine concentrations in the samples seized in the Minas Gerais state (MG samples) ranged from 63.9 to 753mgg(-1).
Caffeine
was the main adulterant found in 76% of the MG samples, ranging in concentration from 5.5 to 645.3mgg(-1). Lidocaine was found in 66.7% of the MG samples, with concentrations ranging from 16.3 to 576.7mgg(-1). Benzocaine was found in only one MG sample, at a concentration of 84.8mgg(-1). Fourteen elements were identified by
ICP
-OES, and a wide variation was observed in the concentrations of Ca, Mg, Na, P, Al, Fe, Mn and Zn. Pearson Product-moment Correlations between the analytes allowed the constituents to be associated with the chemicals used in the manufacturing of cocaine and with some common diluents. The study of the purity of cocaine and the presence and concentration of adulterants and inorganic constituents is important because the latter can have deleterious effects on health.
...
PMID:Evaluation of the composition of street cocaine seized in two regions of Brazil. 2418 44
This article presents the findings of a study investigating the feasibility of using a magnetic field assisted technique for the water-based extraction of mineral components, polyphenols, and
caffeine
from dry black and green tea leaves. The authors present a concept of applying constant and variable magnetic fields in the process of producing water-based infusions from selected types of tea. Analyses investigating the effectiveness of the proposed technique in comparison with conventional infusion methods assessed the contents of selected mineral components-i.e., Al, Ca, Cu, K, Mg, P, S, and Zn-which were examined with the use of
ICP
-OES. The contents of
caffeine
and polyphenolic compounds were assessed using the HPLC. A changing magnetic field permitted an increased effectiveness of extraction of the mineral components,
caffeine
, and polyphenols. The findings support the conclusion that a changing magnetic field assisted extraction method is useful for obtaining biologically valuable components from tea infusions.
...
PMID:Comparison of the Effectiveness of Water-Based Extraction of Substances from Dry Tea Leaves with the Use of Magnetic Field Assisted Extraction Techniques. 2897 65
The adaption of an parallel-path poly(tetrafluoroethylene)(PTFE)
ICP
-nebulizer to an evaporative light scattering detector (ELSD) was realized. This was done by substituting the originally installed concentric glass nebulizer of the ELSD. The performance of both nebulizers was compared regarding nebulizer temperature, evaporator temperature, flow rate of nebulizing gas and flow rate of mobile phase of different solvents using
caffeine
and poly(dimethylsiloxane) (PDMS) as analytes. Both nebulizers showed similar performances but for the parallel-path PTFE nebulizer the performance was considerably better at low LC flow rates and the nebulizer lifetime was substantially increased. In general, for both nebulizers the highest sensitivity was obtained by applying the lowest possible evaporator temperature in combination with the highest possible nebulizer temperature at preferably low gas flow rates. Besides the optimization of detector parameters, response factors for various PDMS oligomers were determined and the dependency of the detector signal on molar mass of the analytes was studied. The significant improvement regarding long-term stability made the modified ELSD much more robust and saved time and money by reducing the maintenance efforts. Thus, especially in polymer HPLC, associated with a complex matrix situation, the PTFE-based parallel-path nebulizer exhibits attractive characteristics for analytical studies of polymers.
...
PMID:Adaption of a parallel-path poly(tetrafluoroethylene) nebulizer to an evaporative light scattering detector: Optimization and application to studies of poly(dimethylsiloxane) oligomers as a model polymer. 2990 70