Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0268318 (ICP)
10,007 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Forest health status in Europe is assessed by the International Cooperative Programme on Assessment and Monitoring of Air Pollution Effects on Forests (ICP Forests). Established by the Convention on Long-Range Transboundary Air Pollution (CLRTAP) under the United Nations Economic Commission for Europe (UNECE), the ICP Forests has been monitoring forest condition in close cooperation with the European Commission (EC) for 20 years. The present paper describes the latest results of the deposition measurements on permanent monitoring plots and of the extensive defoliation sample survey. The findings reveal marked spatial patterns in bulk and throughfall depositions of nitrate (N-NO3(-)), ammonium (N-NH4(+)), and sulfate (S-SO4(2-)), as well as an obvious decrease in bulk and throughfall deposition of sulfate. Latest analyses of defoliation data confirm previous results, indicating a high correlation with weather extremes.
...
PMID:Forest health status in Europe. 1745 Feb 77

Aiming to determine the plutonium amount as well as its isotopic composition, in particular, in swipe samples for safeguards purposes, an analytical method was developed with a plutonium separation step based on extraction chromatography using 2 cm TEVA columns and detection with quadrupole ICP-MS applying an ultra-sonic nebulizer coupled with membrane desolvation system. The method was successfully applied to New Brunswick plutonium certified reference materials as well as to Lawrence Livermore National Laboratory round robin samples, based on the round robin samples provided by the Institute for Reference Materials and Measurements (Belgium), as part of the Regular European Interlaboratory Measurement Evaluation Programme (REIMEP), campaign 16 (isotopic abundances of plutonium in plutonium nitrate samples), with a total plutonium amount between 1 and 0.25 ng per sample. After the introduction of an additional separation step, it was also possible to carry out precise and accurate total plutonium, (240)Pu/(239)Pu, (241)Pu/(239)Pu and (242)Pu/(239)Pu atom ratios determination in sediment sample showing its applicability to environmental samples in general, reaching a detection limit equivalent to 5 mBq(239)Pu kg(-1).
...
PMID:Application of ICP-QMS for the determination of plutonium in environmental samples for safeguards purposes. 1754 30

Pd-based catalysts provide efficient and selective reduction of several drinking water contaminants, but their long-term application requires effective treatments for catalyst regeneration following fouling by constituents in natural waters. This studytested alumina-supported Pd-Cu and Pd-In bimetallic catalysts for nitrate reduction with H2 after sulfide fouling and oxidative regeneration procedures. Both catalysts were severely deactivated after treatment with microM levels of sulfide. Regeneration was attempted with dissolved oxygen, hydrogen peroxide, sodium hypochlorite, and heated air. Only sodium hypochlorite and heated air were effective regenerants, specifically restoring nitrate reduction rates for a Pd-In/gamma-Al2O3 catalyst from 20% to between 39 and 60% of original levels. Results from ICP-MS revealed that sodium hypochlorite caused dissolution of Cu from the Pd-Cu catalyst but that the Pd-In catalyst was chemically stable over a range of sulfide fouling and oxidative regenerative conditions. Analysis byXPS indicated that PdS and In2S3 complexes form during sulfide fouling, where sulfur is present as S2-, and that regeneration with sodium hypochlorite converts a portion of the S2- to S6+, with a corresponding increase in reduction rates. These results indicate that Pd-In catalysts show exceptional promise for being robust under fouling and regeneration conditions that may occur when treating natural waters.
...
PMID:Regeneration of sulfur-fouled bimetallic Pd-based catalysts. 1782 22

A direct sampling graphite furnace atomic absorption spectrometric (DS-GFAAS) method for the determination of Cd, Pb, Cr, Ni, Co and Cu in paints has been developed. Serigraphy, acrylic and tattoo paints were analysed. Approaches like pyrolysis and atomization temperatures, modifiers and sample mass introduced in the atomizer were studied. Quantification was performed using calibration curves measured with aqueous standard solutions pipetted onto the platform. The sample mass introduced in the graphite tube ranged from 0.02 to 8.0 mg. Palladium was used as modifier for Cd, Pb and Cu, while Mg(NO3)2 was used for Co. For Ni determination, the graphite platform was covered with carbon powder. The characteristic masses of Cd, Pb, Cr, Ni, Co and Cu were 1.4, 22.5, 7.9, 11.0, 9.6 and 12.5 pg, while the limits of detection were 0.0004, 0.001, 0.03, 0.22, 0.11 and 0.05 microg g(-1) of Cd, Pb, Cr, Ni, Co and Cu, respectively. The accuracy was determined by comparison of the results with those obtained by inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectrometry (GFAAS), using liquid sampling of digests. For matrix characterization, major and minor elements (Al, Mg, Ba, Ca, Cr, Cu, Pb, Sr, Ti and Mg) were determined by inductively coupled plasma optical emission spectrometry (ICP OES).
...
PMID:Determination of trace elements in paints by direct sampling graphite furnace atomic absorption spectrometry. 1793 3

Nitrate salts have become of greater importance in the decay of materials from historical buildings due to changes in the environment. This work presents an analytical diagnosis methodology to evaluate the impact of nitrate salts in mortars and bricks, combining noninvasive and microdestructive analytical techniques together with chemometric and thermodynamic data analyses. The impact of nitrate salts cannot be well ascertained if other soluble salts are not taken into account. Therefore, the principal results from this work relate to nitrate salts but some results for other kinds of salts are included. Data from Raman microprobe spectroscopy and micro X-ray fluorescence (micro-XRF) are used to characterise the original composition and a first approximation of the nature of the decay compounds, mainly nitrates. The soluble salts are extracted and the anions and cations are quantified by means of ion chromatography with conductimetric detection for anions/cations and inductively coupled plasma mass spectrometry (ICP/MS) for cations. The values obtained allow two different data treatments to be applied. First, chemometric analysis is carried out to search for correlations among anions and cations. Second, thermodynamic modelling with the RUNSALT program is performed to search for environmental conditions of soluble salt formation. All the results are finally used to diagnose the impact of nitrates.
...
PMID:Analytical diagnosis methodology to evaluate nitrate impact on historical building materials. 1826 64

Eleven day-old grass pea plants (Lathyrus sativus L.) were grown hydroponically for 96 h in the presence of 0.5 mM lead nitrate (Pb(NO(3))(2)). The survival rate was 100%. The mean lead content (measured by ICP-OES) in root tissues was 153 mg Pb g(-1) dry matter. Over three quarters of the lead was not labile. Compared with control plants, lead-exposed plants showed a six-fold, two-fold and three and a half-fold reduction in their root calcium, zinc and copper contents, respectively. Together, these results suggested that Lathyrus sativus L. was tolerant to a deficiency in essential nutrients and able to store large amounts of lead in its root tissues. Therefore, it could be used for the development of new rhizofiltration systems.
...
PMID:Lead accumulation in the roots of grass pea (Lathyrus sativus L.): a novel plant for phytoremediation systems? 1894 Jul 1

Trace Mn, Fe and Cu in sodium were determined by chemical modification/graphite furnace atomic absorption spectrometry. The sodium sample was changed into NaOH in a desiccator by room temperature water vapor generated under reduced pressure, then the NaOH was dissolved in water and HNO(3) was added to give a clear solution. The solution was analysed by chemical modification/graphite furnace atomic absorption spectrometry. A nickel nitrate modifier was effective in improving integrated absorbance signals and the reproducibility of measurement. Analytical results for Mn, Fe and Cu were 170, 970 and 210 ng/g and relative standard deviations (n = 5) were 3.5, 5.8 and 6.7%, respectively. These results agreed with the values obtained from a chelating resin preconcentration/ICP-AES method.
...
PMID:Determination of manganese, iron and copper in sodium by chemical modification/graphite furnace atomic absorption spectrometry. 1896 9

The separation of silver from a uranium matrix has been carried out using Cyanex-471X (triisobutylphosphine sulphide) in xylene. The effects of various parameters such as the Cyanex-471X concentration, the nitric acid molarity, the contact time and the nitrate ion concentration on the extraction of silver have been studied. The silver metal ion species extracted into the organic phase was found to be Ag(NO(3)).2S (where S is Cyanex-471X). The stripping of silver into an aqueous medium was carried out with 5% NaHSO(3), followed by its determination using ICP-AES.
...
PMID:ICP-AES determination of silver after chemical separation from uranium matrix. 1896 35

A system for separation of zinc traces from large amounts of cadmium is proposed in this paper. It is based on the solid-phase extraction of the zinc in the form of thiocyanate complexes by the polyurethane foam. The following parameters were studied: effect of pH and of the thiocyanate concentration on the zinc extraction, shaking time required for quantitative extraction, amount of PU foam necessary for complete extraction, conditions for the separation of zinc from cadmium, influence of other cations and anions on the zinc sorption by PU foam, and required conditions for back extraction of zinc from the PU foam. The results show that zinc traces can be separated from large amounts of cadmium at pH 3.0+/-0.50, with the range of thiocyanate concentration from 0.15 to 0.20 mol l(-1), and the shaking time of 5 min. The back extraction of zinc can be done by shaking it with water for 10 min. Calcium, barium, strontium, magnesium, aluminum, nickel and iron(II) are efficiently separated. Iron(III), copper(II) and cobalt(II) are extracted simultaneously with zinc, but the iron reduction with ascorbic acid and the use of citrate to mask copper(II) and cobalt(II) increase the selectivity of the zinc extraction. The anions nitrate, chloride, sulfate, acetate, thiosulphate, tartarate, oxalate, fluoride, citrate, and carbonate do not affect the zinc extraction. Phosphate and EDTA must be absent. The method proposed was applied to determine zinc in cadmium salts using 4-(2-pyridylazo)-resorcinol (PAR) as a spectrophotometric reagent. The result achieved did not show significant difference in the accuracy and precision (95% confidence level) with those obtained by ICP-AES analysis.
...
PMID:Quantitative separation of zinc traces from cadmium matrices by solid-phase extraction with polyurethane foam. 1896 83

Modified silicagel (C18) was studied for separation and preconcentration of platinum group metals (Ru, Rh, Pd, Os, Ir and Pt) as ion associates of their chlorocomplexes with cation of onium salt N(1-carbaethoxypentadecyl)-trimethyl ammonium bromide. Sample containing HCl and the onium salt was pumped through the column. After elution with ethanol the eluate was evaporated in the presence of HCl. Resulting aqueous solutions were analysed with inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). Recovery values of 1-20 mug Pt and Pd from 50 ml of synthetic pure solution were 100+/-3 and 100+/-1%, respectively, however, they diminished with increasing sample volume and in the presence of the real sample matrix or nitrate ions. Samples of engine soot (NIES No. 8), decomposed by low pressure oxygen high-frequency plasma, and airborne particulates from dust filters of meteorological stations, leached with HNO(3) and H(2)O(2), were analysed. A reasonable agreement was found between ICP-MS and ICP-AES results for airborne dust samples and the values comparable with those in literature were determined in NIES No. 8.
...
PMID:Preconcentration of platinum group metals on modified silicagel and their determination by inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry in airborne particulates. 1896 26


<< Previous 1 2 3 4 5 6 7 8 9 10 Next >>