A novel chelating resin functionalized with serine diacetic acid moiety was synthesized by using chitosan as base material, and applied to the collection/concentration of trace elements in environmental water samples, followed by the determination using inductively coupled plasma-atomic emission spectrometer (ICP-AES). The synthesized resin, crosslinked chitosan serine diacetic acid (CCTS-SDA), showed good adsorption behavior toward trace amounts of Cd, Pb, Cu, Ni, V, Ga, Sc, In, and Th in a wide pH range. Additionally, rare earth elements also can be retained on the resin at neutral pH region. The adsorbed elements can be easily eluted with 1 mol L(-1) of nitric acid, and their recoveries were found to be 90-100%. The
CCTS
-SDA was packed in a mini-column, which was then installed in a computer-controlled auto-pretreatment system (Auto-Pret System) for on-line trace elements collection and determination with
ICP
-AES. Experimental parameters which related to the improvement of sensitivity and reproducibility were optimized. The limits of detection (LOD) for 13 elements were found to be in sub-ppb level. The proposed method with
CCTS
-SDA resin was successfully applied to the determination of trace elements in river water samples. The method was validated by determining a certified reference material of river water, SLRS-4.
...
PMID:Synthesis of novel chitosan resin derivatized with serine diacetic acid moiety and its application to on-line collection/concentration of trace elements and their determination using inductively coupled plasma-atomic emission spectrometry. 1738 95
A novel chitosan-based resin functionalized with threonine moiety was synthesized, and applied to the collection/concentration of Mo, V and Cu in environmental water samples, followed by their determination using inductively coupled plasma-atomic emission spectrometer (ICP-AES). The synthesized resin, cross-linked chitosan-threonine (CCTS-Thr), showed good adsorption behavior toward trace amounts of Mo, V and Cu in a wide pH range. The adsorbed elements can be easily eluted using 2molL(-1) of nitric acid, and their recoveries were found to be 90-100%. The
CCTS
-Thr was packed in a mini-column, which was then installed in a computer-controlled auto-pretreatment system (Auto-Pret System) for on-line trace elements collection and determination by
ICP
-AES. Experimental parameters related to the improvement of sensitivity and reproducibility were optimized. The limits of detection (LODs) for target metals were found to be in sub-ppb level. The proposed method with
CCTS
-Thr resin was successfully applied to the determination of Mo, V and Cu in environmental water samples. The recovery test showed that common matrices which exist in environmental water samples did not interfere with the determination.
...
PMID:Synthesis of cross-linked chitosan functionalized with threonine moiety and its application to on-line collection/concentration and determination of Mo, V and Cu. 1837 37
Chitosan resin possessing the 4-hydroxyphthalic acid moiety (
CCTS
-HPA resin) was synthesized. This resin could adsorb chromium(VI) at pH 3 to 5, whereas chromium(III) could not be retained in the acidic region. The
CCTS
-HPA resin was used for collecting chromium(VI), and ME-03 resin was used for collecting chromium(III) before their measurement by
ICP
-AES measurement. Both resins were packed in mini-columns and installed serially in a laboratory-assembled automated pretreatment system (Auto-Pret System). The system provides a highly sensitive and fully automated procedure for the speciation of chromium(III) and chromium(VI). The proposed system was successfully applied to speciation of chromium(III) and chromium(VI) using 5 ml of water samples. The detection limits (S/N = 3) of chromium(III) and chromium(VI) were 0.06 and 0.04 microg l(-1), respectively, along with an analysis time of 7 min 45 s for both chromium species. The lowest determinable concentrations for both chromium species were about 0.5 microg l(-1), which was enough for the speciation of chromium in water samples.
...
PMID:Automated pretreatment system for the speciation of Cr(III) and Cr(VI) using dual mini-columns packed with newly synthesized chitosan resin and ME-03 resin. 1913 72