Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0268318 (
ICP
)
10,007
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Inductively coupled plasma mass spectrometry (ICP-MS) is a suitable tool for multi-element analysis at low concentration levels. Rare earth element (REE) determinations in standard reference materials and small volumes of molten ice core samples from Antarctica have been performed with an
ICP
-time of flight-MS (ICP-TOF-MS) system. Recovery rates for REE in e.g.
SPS
-SW1 amounted to approximately 103%, and the relative standard deviations were 3.4% for replicate analysis at REE concentrations in the lower ngL(-1) range. Analyses of REE concentrations in Antarctic ice core samples showed that the
ICP
-TOF-MS technique meets the demands of restricted sample mass. The data obtained are in good agreement with
ICP
-Quadrupole-MS (ICP-Q-MS) and
ICP
-Sector Field-MS (ICP-SF-MS) results. The
ICP
-TOF-MS system determines accurately and precisely REE concentrations exceeding 5ngL(-1) while between 0.5 and 5ngL(-1) accuracy and precision are element dependent.
...
PMID:Rare earth elements determined in Antarctic ice by inductively coupled plasma--time of flight, quadrupole and sector field-mass spectrometry: An inter-comparison study. 1857 77
The applicability of commercial screen-printed gold electrodes (SPGEs) connected to a portable potentiostat and a laptop has been explored to optimize a new square wave anodic stripping voltammetric method for on-site determination of soluble Cu(II) in atmospheric deposition samples taken around an industrial complex. Electrode conditioning procedures, chemical and instrumental variables have been optimized to develop a reliable method capable of measuring dissolved copper with a detection limit of 3.7 ng mL(-1), useful for pollution monitoring or screening purposes. The proposed method was tested with the SLRS-5 River Water for Trace Metals (recoveries 109.9-113.1%) and the
SPS
-SW2 Batch 121 Elements in Surface Waters (recoveries 93.2-97.6%). The method was applied to soluble Cu(II) measurement in liquid samples taken by a total atmospheric deposition collector modified with a quartz filter for soluble and insoluble elemental speciation. The voltammetric measurements on field samples were tested in the lab by a reference
ICP
-MS method, with good agreement. The proposed method proved capability for field operation during a two weeks monitoring campaign.
...
PMID:Miniaturized voltammetric stripping on screen printed gold electrodes for field determination of copper in atmospheric deposition. 2315 45