Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0267964 (
PAA
)
2,561
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Eighty bovine incisors were ground on 320-
grit
silicone carbide paper and cleaned with fluoride-free prophylaxis paste. The enamel surface conditions were: 1. no conditioning; 2. salicylic acid (10%, 10s); 3. benzoic acid (10%, 10s); 4. air polishing with sodium hydrogen carbonate/Prophy-Jet; 5. Prophy-Jet, followed by polyacrylic acid (
PAA
, 10%, 10 s); 6.
PAA
, followed by saliva contamination; 7.
PAA
; 8. phosphoric acid (37%, 10 s). Fuji Ortho II LC (GC) was used as a bracket adhesive in groups 1 t0 7, and in group 8 Concise orthodontic (3M). Stainless steel lingual buttons were placed by hand. Polymerisation with visible light was carried out 20 s from mesial, distal, incisal and gingival. After 24 h storage in tap water at room temperature the shear bond strengths were tested in accordance with ISO specification TC 106/SC/WG16. Mean values of the groups were compared using Student's t-test. Group 7 (
PAA
) attained the highest mean shear strength (in comparison with control group): 28 MPa. This was both significantly different from the control group (Concise, 33 MPa) and highly significant in comparison with the other groups (< 16 MPa). The shear bond strength of Fuji Ortho II LC on
PAA
conditioned enamel indicates the clinical applicability of this material.
...
PMID:Light-cured glass ionomer cement as a bracket adhesive with different types of enamel conditioners. 920 Aug 93
The performance of medical implants and devices is dependent on the biocompatibility of the interfacial region between tissue and the implant material. Polymeric hydrogels are attractive materials for use as biocompatible surface coatings for metal implants. In such systems, a factor that is critically important for the longevity of an implant is the formation of a robust bond between the hydrogel layer and the implant metal surface and the ability for this assembly to withstand physiological conditions. Here, we describe the grafting of cross-linked hydrogel networks to titanium surfaces using
grit
-blasting and subsequent chemical functionalization using a silane-based adhesion promoter. Metal surface characterization was carried out using profilometry, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDX) analysis. Hydrogel layers composed of poly(ethylene glycol)-dimethacrylate (PEG-DMA), poly(2-hydroxyethylmethacrylate) (PHEMA), or poly(ethylene glycol)/poly(acrylic acid) (PEG/
PAA
) semi-interpenetrating polymer networks (semi-IPNs) have been prepared. The mechanical properties of these hydrogel-metal assemblies have been characterized using lap-shear measurements, and the surface morphology was studied by SEM and EDX. We have shown that both high surface roughness and chemical functionalization are critical for adhesion of the hydrogel layer to the titanium substrate.
...
PMID:Grafting of cross-linked hydrogel networks to titanium surfaces. 2436 60