Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0231807 (
exertional dyspnea
)
3,402
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Bulk X-ray diffraction (XRD), synchrotron X-ray microdiffraction (microXRD), and scanning electron microscopy/ energy-dispersive X-ray spectroscopy (SEM/
EDS
) were used to characterize solids in residual sludge from single-shell underground waste tanks C-203 and C-204 at the U.S. Department of Energy's Hanford Site in southeastern Washington state. Cejkaite [Na4(UO2)(CO3)3] was the dominant crystalline phase in the C-203 and C-204 sludges. This is one of the few occurrences of cejkaite reported in the literature and may be the first documented occurrence of this phase in radioactive wastes from
DOE
sites. Characterization of residual solids from water leach and selective extraction tests indicates that cejkaite has a high solubility and a rapid rate of dissolution in water at ambient temperature and that these sludges may also contain poorly crystalline Na2U207 [or clarkeite Na[(UO2)O(OH)](H2O)0-1] as well as nitratine (soda niter, NaNO3), goethite [alpha-FeO(OH)], and maghemite (gamma-Fe2O3). Results of the SEM/
EDS
analyses indicate that the C-204 sludge also contains a solid that lacks crystalline form and is composed of Na, Al, P, O, and possibly C. Other identified solids include Fe oxides that often also contain Cr and Ni and occur as individual particles, coatings on particles, and botryoidal aggregates; a porous-looking material (or an aggregate of submicrometer particles) that typically contain Al, Cr, Fe, Na, Ni, Si, U, P, O, and C; Si oxide (probably quartz); and Na-Al silicate(s). The latter two solids probably represent minerals from the Hanford sediment, which were introduced into the tank during prior sampling campaigns or other tank operation activities. The surfaces of some Fe-oxide particles in residual solids from the water leach and selective extraction tests appear to have preferential dissolution cavities. If these Fe oxides contain contaminants of concern, then the release of these contaminants into infiltrating water would be limited by the dissolution rates of these Fe oxides, which in general have lowto very low solubilities and slow dissolution rates at near neutral to basic pH values under oxic conditions.
...
PMID:Residual waste from Hanford tanks 241-C-203 and 241-C-204. 1. Solids characterization. 1683 May 37
Environmental aerosolized particulates pose a potential risk to human health worldwide. Among others, high amounts of contaminants are generated especially in newly industrializing countries in the vicinity of industrial manufacturing, mining operations, but also during agricultural and natural processes. As an example of the needed multi-disciplinary diagnostic and differential diagnostic approach, we report a case of a 59-year old industrial worker who has suffered from chronic bronchitis and progressive
dyspnea on exertion
for 8years. He showed severe lung function impairment, a cavity in his right upper lung lobe, nodular and irregular opacities, fibrotic pleural changes and emphysema. According to the occupational history and the industrial hygiene report, he had been engaged in the production of various refractory materials and been exposed to very high levels of inorganic dust, especially to silica, silicon carbide and aluminum compounds, but also to carbon and other dusty materials for 28years. Histopathology of the two resected lung segments showed focally infarcted granulomas and chronic inflammation. Stains for organisms were negative. The lung tissue away from the granulomas showed significant dust deposition including dust macules. In spite of the inorganic dust deposits, with adjacent tissue lesions evident from the radiological findings (which were interpreted as atypical for pneumoconiosis) and the presence of granulomas in lung tissue, a diagnosis of necrotizing sarcoid granulomatosis was made, which was later changed to mixed-dust pneumoconiosis on further detailed examination. Scanning Electron Microscopy/Energy-Dispersive X-ray Spectroscopy (SEM/
EDS
) analysis of individual particles showed predominantly Si (silica or silicon carbide [SiC]) and Al particles (consistent with aluminum metal and/or oxide), as well as numerous Al silicates, Ti, and occasional Zr, Nb, V, steel, including Si fibers (consistent with SiC). We present the controversy about the pathogenesis of the lung disorder and whether it represents an occupational disease - which is more or less representative for many such cases.
...
PMID:Mixed-dust pneumoconiosis: Review of diagnostic and classification problems with presentation of a work-related case. 3036 72