Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0220723 (
PCA
)
4,687
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
We developed a new device for processing frozen myocardial biopsies. Frozen samples of 20 to 50 mg were dropped into a 25 ml stainless steel centrifuge tube held in a custom-made aluminium container precooled in liquid nitrogen. A stainless steel pestle attached to a stainless steel disk was driven by a modified heavy-duty staple gun to pulverise the tissue rapidly at low temperatures. The tissue powder was extracted with 0.3N
PCA
at 0 degree C in the centrifuge tube which was then transferred to a Sorvall super-speed centrifuge. Values for adenosine triphosphate (ATP) were 5.6 +/- 0.7 mumol . g-1 wet weight (mean +/- SD).
Creatine phosphate
(CP) yield was 12.2 +/- 3 mumol . g-1 wet weight. The % recovery of an added internal standard for ATP was 86 +/- 18% and for CP 90 +/- 16% with the new method.
...
PMID:A new device for the efficient pulverisation and extraction of myocardial biopsies for high energy phosphate analysis. 401 21
Functional metabolomics of skeletal muscle involves the simultaneous identification and quantification of a large number of metabolites. For this purpose, the extraction of metabolites from animal tissues is a crucial technical step that needs to be optimized. In this work, five extraction methods for skeletal muscle metabolome analysis using liquid chromatography tandem mass spectrometry (LC-MS/MS) were tested. Bird skeletal muscles sampled postmortem and quenched in liquid nitrogen were used. Three replicates of the same sample were extracted using the following solvent systems of varying polarity: boiling water (BW, +100 degrees C), cold pure methanol (CPM, -80 degrees C), methanol/chloroform/water (MCW, -20 degrees C), boiling ethanol (BE, +80 degrees C), and perchloric acid (
PCA
, -20 degrees C). Three injections by extraction were performed. The BW extraction showed the highest recovery of metabolites with the lowest variability (<10%) except for
creatine-phosphate
(
creatine-P
). Considering yield (area of the peaks), reproducibility, and ease, the current experiment drew a scale for the muscle metabolome extraction starting from the best to the least convenient: BW>MCW>CPM>PCABE. In addition, the semiquantification of metabolites in two muscles showing different metabolic and contractile properties was carried out after BW extraction and showed expected differences in metabolite contents, thereby validating the technique for biological investigations. In conclusion, the BW extraction is recommended for analysis of skeletal muscle metabolome except for
creatine-P
, which was poorly recovered with this technique.
...
PMID:Analysis of skeletal muscle metabolome: evaluation of extraction methods for targeted metabolite quantification using liquid chromatography tandem mass spectrometry. 2002 96
This article is report the study of the pharmacokinetics and metabolic disposition of exogenous
phosphocreatine
(PCr) in rats by means of an ion-pair HPLC-UV assay. PCr and its metabolite creatine (Cr) and related-ATP in rat plasma and red blood cell (RBC) were simultaneously determined. A blank plasma and RBC were initially run for baseline subtraction. Plasma and RBC samples were deproteinized with 6%
PCA
prior to HPLC. Following i.v. administration of PCr 500 mg x kg(-1) and 1 000 mg x kg(-1) the C-T curve could be described by the two-compartment model with t1/2beta 22.5-23.3 min, V(d) 0.956 4-0.978 6 L x kg(-1), CL 0.029 L. kg(-1) x min(-1). The Cr as PCr degraded product appeared as early as 2 min post i.v. dosing with t(max) 20 min, t1/2kappa (m) 40.6-42.7 min and f(m) 60%-76%. After po administration of PCr, the parent drug in plasma was undetectable, but the metabolite Cr was detected with t(max) 65-95 min, t1/2kappa (m) 56.0-57.7 min, metabolite-based bioavailability F(m) 55.02%-62.31%. PCr i.v. administration resulted in significant elevation of ATP level in RBC but not in plasma, the related-ATP in RBC was characterized by t(max) 68-83 min, t1/2kappa 49-52 min. In RBC no exogenous PCr was found but Cr was detected following i.v. administration of PCr, with the t(max) 120 min and t1/2k (m) 70 min for Cr. The above results indicate that PCr eliminates and bio-transforms in body very rapidly; K > K(m) confers ERL, instead of FRL, type upon the metabolic disposition of Cr. Following po administration of PCr, the degraded product Cr is absorbed but not the parent drug PCr. The formed Cr can be accounted for by most of i.v. and po PCr. Intravenous dosing leads apparently increased and sustained Cr and related-ATP concentration in RBC.
...
PMID:[Pharmacokinetics and metabolic disposition of exogenous phosphocreatine in rats]. 2146 12