For routine pretreatment verification of innovative treatment techniques such as (intensity modulated) dynamic arc therapy and helical TomoTherapy, an on-line and reliable method would be highly desirable. The present solution proposed by TomoTherapy, Inc. (Madison, WI) relies on film dosimetry in combination with up to two simultaneous ion chamber point dose measurements. A new method is proposed using a 2D ion chamber array (Seven29, PTW, Freiburg, Germany) inserted in a dedicated octagonal phantom, called Octavius. The octagonal shape allows easy positioning for measurements in multiple planes. The directional dependence of the response of the detector was primarily investigated on a dual energy (6 and 18 MV) Clinac 21EX (Varian Medical Systems, Palo Alto, CA) as no fixed angle incidences can be calculated in the Hi-
Art
TPS of TomoTherapy. The array was irradiated from different gantry angles and with different arc deliveries, and the dose distributions at the level of the detector were calculated with the
AAA
(Analytical Anisotropic Algorithm) photon dose calculation algorithm implemented in Eclipse (Varian). For validation on the 6 MV TomoTherapy unit, rotational treatments were generated, and dose distributions were calculated with the Hi-
Art
TPS. Multiple cylindrical ion chamber measurements were used to cross-check the dose calculation and dose delivery in Octavius in the absence of the 2D array. To compensate for the directional dependence of the 2D array, additional prototypes of Octavius were manufactured with built-in cylindrically symmetric compensation cavities. When using the Octavius phantom with a 2 cm compensation cavity, measurements with an accuracy comparable to that of single ion chambers can be achieved. The complete Octavius solution for quality assurance of rotational treatments consists of: The 2D array, two octagonal phantoms (with and without compensation layer), an insert for nine cylindrical ion chambers, and a set of inserts of various tissue equivalent materials of different densities. The combination of the 2D array with the Octavius phantom proved to be a fast and reliable method for pretreatment verification of rotational treatments. Quality control of TomoTherapy patients was reduced to a total of approximately 25 min per patient.
...
PMID:On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom. 1798 28
Gas-filled temporary tissue expanders (TTEs), implanted to assist in post mastectomy breast reconstructions, are expected to produce increased dosimetric uncertainty in breast radiotherapy treatments, due to their containing both a substantial metallic component and a comparatively large volume of gas. This study therefore builds on previous investigations of the dosimetric effects of gas-filled TTEs in static photon and electron beams, by examining the effects of these implants on dose distributions from common modulated rotational treatment techniques; volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT). Radiochromic film measurements were used to evaluate the accuracy of VMAT and HT dose calculations, for a humanoid phantom augmented with a sample Aeroform CO
2
-filled TTE (AirXpanders Inc, San Jose, USA) as well as purpose-designed and 3D printed "breast tissue." Results showed that the TomoTherapy Hi-
Art
VoLO convolution-superposition algorithm (Accuray Inc, Sunnyvale, USA) produced comparatively accurate calculations of treatment dose within this complex phantom, including immediately anterior and posterior to the TTE. The Varian Eclipse Acuros (AXB) algorithm generally showed better agreement with the film measurement than the Varian Eclipse
AAA
algorithm (Varian Medical Systems, Palo Alto, USA), although the film measurements showed regions of 5% to 10% disagreement with both
AAA
and AXB in the dosimetrically-challenging region on the anterior side of the implant. Although the Aeroform CO
2
-filled TTE has substantial and obvious effects on the downstream dose from a static photon beam, the results of this study showed how inverse-planning of modulated rotational radiotherapy treatments can produce modulated fluence distributions that compensate for the dramatic density heterogeneities in the implant. Despite some disagreements with the planned dose, all film measurements showed that the use of inverse-planned modulated rotational photon beams resulted in comparatively homogeneous coverage of the radiotherapy target, in the complex patient-like phantom with a gas-filled TTE. Due to the importance of matching each planned fluence distribution to the density distribution within each TTE, careful use of available 3D imaging techniques is advisable, when modulated rotational radiotherapy treatments are delivered to patients with gas-filled TTEs.
...
PMID:Effects of gas-filled temporary breast tissue expanders on radiation dose from modulated rotational photon beams. 3266 Aug 88