Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0154059 (Esophagus)
2,950 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Using a recently developed in vitro preparation of vagal afferent pathways, we examined the role of TRPV1 and ASIC3 on the mechano- and chemosensitive properties of gastroesophageal sensory neurons. Esophagus, stomach, and the intact vagus nerves up to the central terminations were carefully dissected from TRPV1 and ASIC3 knockout mice and wild-type controls. The organ preparation was placed in a superfusion chamber to obtain intracellular recordings from the soma of nodose neurons during luminal stimulation of esophagus and stomach. The proximal esophagus and distal stomach were separately intubated to allow perfusion and graded luminal distension. In wild-type mice, mechanosensitive neurons were activated by low distension pressures and encoded stimulus intensity over the entire range tested. Luminal acidification significantly transiently increased the resting frequency but did not alter responses to subsequent mechanical stimulation. ASIC3 and TRPV1 knockout significantly blunted responses to distension compared with wild-type controls, with deletion of TRPV1 having a more significant effect than ASIC3 deletion. Luminal acidification did not activate mechanosensory neurons in ASIC3 and TRPV1 knockout mice. Our data demonstrate a role of TRPV1 in chemo- and mechanosensation of gastroesophageal afferents. ASIC3 may contribute to acid sensation but plays a more subtle role in responses to distending stimuli. Considering the importance of acid in dyspeptic symptoms and gastroesophageal reflux, TRPV1 or ASIC3 may be an attractive target for treatment strategies in patients who do not respond to acid suppressive therapy.
...
PMID:Differential effects of ASIC3 and TRPV1 deletion on gastroesophageal sensation in mice. 1797 30

The EndoFLIP (Endolumenal Functional Lumen Imaging Probe, Crospon Inc, Galway, Ireland) device uses the technique of impedance planimetry to evaluate dimensions and distensibility of the upper and lower esophageal sphincter. The null hypotheses for this study were that EndoFLIP variables would be stable between anesthestic episodes and would not be affected by body position when evaluating the upper and lower esophageal sphincters in healthy dogs. During each of three consecutive general anesthesia episodes administered to eight healthy adult research colony dogs with a standardized protocol, the EndoFLIP catheter was positioned to measure cross-sectional area, intrabag pressure, upper and lower esophageal sphincter length at two different balloon fill volumes (30 and 40 mL) and two body positions (lateral and dorsal recumbency). From these measured variables, a distensibility index was also calculated. Mixed effect analysis of variance was used to evaluate the fixed marginal and interaction effects of anesthesia episode, body position, and balloon volume on measured and calculated variables. For the upper esophageal sphincter significant interactions were present between anesthetic episode and body position for all variables except intrabag pressure; adjusting for body position significant differences were present between anesthetic episodes for all variables except distensibility index; adjusting for anesthetic episode cross-sectional area, intrabag pressure, upper esophageal sphincter length and distensibility index were all affected by body position. For the lower esophageal sphincter distensibility index was the only variable where a significant interaction between anesthesia episode and body position occurred; cross-sectional area, intrabag pressure, and lower esophageal length were not significantly affected by anesthesia episode when adjusting for body position; distensibility index was the only variable significantly affected by body position. Measurements of the geometry of the lower esophageal sphincter as measured by the EndoFLIP device were consistent under conditions of general anesthesia. Similar measurements taken at the upper esophageal sphincter displayed greater variability between anesthetic episodes and were affected to a greater extent by body position. Body position should be standardized in studies using the EndoFLIP to assess geometric and functional characteristics of the upper and lower esophageal sphincters.
Dis Esophagus 2017 Apr 01
PMID:Consistency and effect of body position change on measurement of upper and lower esophageal sphincter geometry using impedance planimetry in a canine model. 2837 75

Luminal distensibility measurement has demonstrated relevance to various disease processes, though its effects on clinical decision-making have been less well understood. This study aims to characterize the clinical impact of impedance planimetry measurement as well as the learning curve associated with its use in the esophagus. A single provider performed distensibility measurement in conjunction with upper endoscopy for a variety of clinical indications with the functional lumen imaging probe (FLIP) over a period of 21 months. Procedural data were prospectively collected and, along with medical records, retrospectively reviewed. Seventy-three procedures (70 patients) underwent esophageal distensibility measurement over the timeline of this study. The most common procedural indications were known or suspected achalasia (32.9%), dysphagia with connective tissue disease (13.7%), eosinophilic esophagitis (12.3%), and dysphagia with prior fundoplication (9.6%). FLIP results independently led to a change in management in 29 (39.7%) cases and supported a change in management in an additional 15 (20.5%) cases. The most common change in management was a new or amended therapeutic procedure (79.5%). Procedural time added by distensibility measurement was greater among earlier cases than among later cases. The median time added overall was 5 minutes and 46 seconds. Procedural time added varied significantly by procedural indication, but changes in management did not. Distensibility measurement added meaningful diagnostic information that impacted therapeutic decision-making in the majority of cases in which it was performed. Procedural time added by this modality is typically modest and decreases with experience.
Dis Esophagus 2017 Aug 01
PMID:Esophageal distensibility measurement: impact on clinical management and procedure length. 2857 49