Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0152030 (skin irritation)
2,146 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

In surveys of three groups of workers occupationally exposed to polychlorinated biphenyls (PCBs) serum PCB concentrations were quantitated as lower chlorinated biphenyls (L-PCBs) and higher chlorinated biphenyls (H-PCBs). Serum L-PCB and H-PCB concentrations were many times greater among workers employed in power capacitor manufacturing than exposed areas. Statistically significant positive correlations of symptoms suggestive of mucous membrane and skin irritation, of systemic malaise, and altered peripheral sensation were noted with increasing concentrations of serum PCB. No clinical abnormalities attributable to exposure to PCB were observed. Serum PCB concentrations were positively and significantly correlated with glutamic-oxalacetic transaminase (SGOT), serum gamma-glutamyl transpeptidase (GGTP), and plasma triglyceride, and inversely correlated with plasma high density lipoprotein-cholesterol. These correlations were present across all study sites. These findings are indicative of PCBs' physiological effect on the liver, whose long-range health significance is unknown. Nevertheless, the consistent positive association of serum PCB with plasma triglyceride and negative association with plasma HDL-cholesterol may have long-term cardiovascular consequences.
...
PMID:Metabolic and health consequences of occupational exposure to polychlorinated biphenyls. 612 23

External electrocardiographic loop recording permits extended cardiac rhythm monitoring and ECG storage before and after device activation. The purpose of the study was to assess the diagnostic yield of external loop recorders in patients with more than two syncopal events within the last 6 months and a negative tilt table test. Twenty-four consecutive patients (51 +/- 14 years, male n = 9) were enrolled with 3 +/- 4 recurrent syncopal events within the last 6 months and no overt structural heart disease. The loop recorder CardioCall continuously records a two-channel ECG via skin electrodes. When activated, up to 4.5 minutes of the ECG preceding activation is stored. The time between tilt table testing and monitoring was 5 +/- 4 weeks. The average monitoring period covered 50 +/- 22 days. Recording was either unsuccessful or terminated prematurely in 5 patients. The reasons were skin irritation secondary to the electrodes in two patients, cable damage in one patient, and two patients inadvertently erased the stored data when replacing the batteries. Fourteen patients activated the loop recorder at least once. Symptoms leading to device activation were syncope (n = 1), dizziness (n = 11), feeling unwell (n = 7), palpitations (n = 5), headaches (n = 1), and chest pain (n = 1). The loop recorder documented sinus tachycardia during the syncopal event. Sinus tachycardia was also observed in 7 other patients, and atrial flutter in two patients. Eight patients had recurrent syncope with two patients experiencing syncope prior to the monitoring period, one syncope occurred in a patient who inadvertently erased the stored data, one event coincided with sinus tachycardia, and 4 (17%) patients had syncope during 15 +/- 10 months after termination of loop monitoring. The external loop recorder was not very useful for arrhythmia detection in patients with syncopal events, no overt heart disease, and a negative tilt table test because the cardiac rhythm was stored in only 1 of 8 (13%) patients with recurrent syncope. Reasons for the low diagnostic yield of external loop recorders were infrequent syncopal events after the baseline evaluation, with rare events during the limited monitoring period in particular, and premature termination or unsuccessful recording in 21% of patients.
...
PMID:Diagnostic yield of external electrocardiographic loop recorders in patients with recurrent syncope and negative tilt table test. 1293 Apr 97