Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0151744 (
myocardial ischemia
)
31,282
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Sonazoid
(formerly NC100100) is a new ultrasound contrast agent for intravenous injection developed by Nycomed-Amersham. It consists of perfluorocarbon microbubbles that are stabilized with a surfactant and are within a well-defined size range (median diameter approximately 3 microm). Due to the low diffusibility and blood solubility of the gas, the controlled size distribution of the microbubbles, and the flexibility of the shell,
Sonazoid
is a free-flowing tracer capable of crossing the pulmonary capillary bed after peripheral intravenous injection. It is stable enough for the duration of the ultrasound examination and provides echo enhancement useful for clinical requirements. The preliminary clinical experience in cardiology indications, including its use in reducing the frequency of inadequate echocardiographic studies in patients with suboptimal echocardiograms, and its use as a myocardial perfusion agent in the setting of acute
myocardial ischemia
is briefly discussed.
...
PMID:Preliminary clinical experience in cardiology with sonazoid. 1099 45
The combination of Doppler tissue imaging and myocardial contrast echocardiography has the potential to provide information about motion and perfusion of the myocardium in a single examination. The purpose of this study was to establish how the presence of ultrasound contrast agent (UCA) affects measurements of Doppler tissue velocities in vivo and in vitro. We performed echocardiography in 12 patients with
ischemic heart disease
before and immediately after a slow intravenous infusion of the UCA Optison, using color Doppler tissue imaging to examine the effect of contrast agents in vivo. The myocardial peak systolic velocities and their integrals were analyzed in digitally stored cineloops before and after contrast administration. To distinguish between methodologic and physiologic factors affecting the measurement of tissue velocity in vitro, experiments with a rotating disk and a flow cone phantom were also carried out for the 3 contrast agents: Optison, Sonovue, and
Sonazoid
. In vivo results show that the values for peak systolic velocity increased by about 10% during contrast infusion, from mean 5.2 +/- 1.8 to 5.7 +/- 2.3 cm/s (P = .02, 95% confidence interval 2%-16%). The increase in myocardial peak systolic velocities was verified in experimental models in which the UCA increased the estimated mean velocity in the order of 5% to 20% for the motion interval of 5 to 7 cm/s, corresponding to the myocardial velocities studied in vivo. The response was similar for all 3 contrast agents and was not affected by moderate variations in concentration of the agent. We have shown that the presence UCA will affect Doppler tissue measurements in vivo and in vitro. The observed bias is presumed to be an effect of harmonic signal contribution from rupturing contrast agent microbubbles and does not indicate biologic or physiologic effects.
...
PMID:Effects of ultrasound contrast agents on Doppler tissue velocity estimation. 1645 19