Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0149958 (complex partial seizures)
2,563 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Coded-aperture imaging of the heart combines the advantages of tomography with good sensitivity, high resolution, and accurate size scaling. Since the images are multiplexed, the method may be adapted to small, portable cameras for bed-side use without sacrificing image resolution. A new coded aperture designed especially for cardiac imaging has been constructed and tested. This aperture incorporates significant improvements over previous designs. Longitudinal tomograms are calculated at 1-cm intervals using a modified ART algorithm. Experimental lateral resulution at 140 keV with a portable scintillation camera is 3.8 mm FWHM at 4 cm, and 7.8 mm FWHM at 12 cm. Dpth resolution determined from a sloping line source is 1.1 cm FWHM at 4 cm, and 2.9 cm at 12 cm. The calculated point-source sensitivities in air at 4 cm and 12 cm, respectively, are 20 and 8 cps/microCi. Images of good diagnostic quality have been obtained in phantoms and in a dog model of acute myocardial infarction, using thallium-201, technetium-99m pyrophosphate, and gated ventricular blood-pool imaging with Tc-labeled red blood cells. Preliminary studies in humans confirm the good results in animals.
...
PMID:Coded-aperture imaging of the heart. 696 79

Advances in fully three-dimensional (3D) image reconstruction techniques have permitted the development of a commercial, rotating, partial ring, fully 3D positron emission tomographic (PET) scanner, the ECAT ART. The system has less than one-half the number of bismuth germanate detectors compared with a full ring scanner with the equivalent field of view, resulting in reduced capital cost. The performance characteristics, implications for installation in a nuclear medicine department, and clinical utility of the scanner are presented in this report. The sensitivity (20 cm diameterx20 cm long cylindrical phantom, no scatter correction) is 11400 cps.kBq-1.ml-1. This compares with 5800 and 40500 cps.kBq-1.ml-1 in 2D and 3D respectively for the equivalent full ring scanner (ECAT EXACT). With an energy window of 350-650 keV the maximum noise equivalent count (NEC) rate was 27 kcps at a radioactivity concentration of approximately 15 kBq.ml-1 in the cylinder. Spatial resolution is approximately 6 mm full width at half maximum on axis degrading to just under 8 mm at a distance of 20 cm off axis. Installation and use within the nuclear medicine department does not appreciably increase background levels of radiation on gamma cameras in adjacent rooms and the dose rate to an operator in the same room is 2 microSv. h-1 for a typical fluorine-18 fluorodeoxyglucose (18F-FDG) study with an initial injected activity of 370 MBq. The scanner has been used for clinical imaging with18F-FDG for neurological and oncological applications. Its novel use for imaging iron-52 transferrin for localising erythropoietic activity demonstrates its sensitivity and resolution advantages over a conventional dual-headed gamma camera. The ECAT ART provides a viable alternative to conventional full ring PET scanners without compromising the performance required for clinical PET imaging.
...
PMID:ECAT ART - a continuously rotating PET camera: performance characteristics, initial clinical studies, and installation considerations in a nuclear medicine department. 904 79

The production of artwork is a complex neurological task. A controlled study of artwork produced by people with epilepsy has not previously been performed. The present report details the results of a three-part study involving 60 subjects from a comprehensive epilepsy center population. Subjects were grouped by the following diagnoses: seizures, partial seizures, complex partial seizures with temporal focus, and nonepileptic events. Data were collected in a blinded fashion. The Formal Elements Art Therapy Scale task showed significant effects in patients with epileptic seizures. The Free Drawing was most sensitive to complex partial seizures with temporal focus, while the Outline was most predictive of nonepileptic events. In addition to giving some insight into the neurological functioning of these subjects, this pilot study provides a basis for the future development of diagnostic tests to be used within this patient group.
...
PMID:A blinded pilot study of artwork in a comprehensive epilepsy center population. 1571 Feb 94

Though the role of reactive oxygen species (ROS) in female infertility has been a subject of rigorous research worldwide, there is inadequate information on the cut-off value of ROS in the oocyte microenvironment beyond which ART outcome may be adversely affected. An upper ROS level in follicular fluid (FF) samples of women undergoing IVF beyond which good quality embryo formation is unlikely, is established. ROS, lipid peroxidation and total antioxidant capacity were estimated. The upper cut-off ROS level beyond which viable embryo formation is not favorable was found to be approximately 107 cps/400 microl FF. This level, determined in women with tubal factor infertility, was further validated in women with endometriosis and PCOS and correlated with fertilization and pregnancy rate and embryo quality. Summarizing, a threshold level in FF has been established for the first time beyond which ROS may be considered toxic for viable embryo formation and pregnancy outcome.
...
PMID:Upper control limit of reactive oxygen species in follicular fluid beyond which viable embryo formation is not favorable. 2040 78