Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0149871 (
deep vein thrombosis
)
12,364
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Autogenous iliac crest has long served as the gold standard for anterior lumbar arthrodesis although added morbidity results from the bone graft harvest. Therefore, femoral ring allograft, or cages, have been used to decrease the morbidity of iliac crest bone harvesting. More recently, an experimental study in the animal showed that harvesting local bone from the anterior vertebral body and replacing the void by a radio-opaque beta-tricalcium phosphate plug was a valid concept. However, such a concept precludes theoretically the use of posterior pedicle screw fixation. At one institution a consecutive series of 21 patients underwent single- or multiple-level circumferential lumbar fusion with anterior cages and posterior pedicle screws. All cages were filled with cancellous bone harvested from the adjacent vertebral body, and the vertebral body defect was filled with a beta-tricalcium phosphate plug. The indications for surgery were failed conservative treatment of a lumbar
degenerative disc disease
or spondylolisthesis. The purpose of this study, therefore, was to report on the surgical technique, operative feasibility, safety, benefits, and drawbacks of this technique with our primary clinical experience. An independent researcher reviewed all data that had been collected prospectively from the onset of the study. The average age of the patients was 39.9 (26-57) years. Bone grafts were successfully harvested from 28 vertebral bodies in all but one patient whose anterior procedure was aborted due to difficulty in freeing the left common iliac vein. This case was converted to a transforaminal interbody fusion (TLIF). There was no major vascular injury. Blood loss of the anterior procedure averaged 250 ml (50-350 ml). One tricalcium phosphate bone plug was broken during its insertion, and one endplate was broken because of wrong surgical technique, which did not affect the final outcome. One patient had a right lumbar plexopathy that was not related to this special technique. There was no retrograde ejaculation, infection or pseudoarthrosis. One patient experienced a
deep venous thrombosis
. At the last follow up (mean 28 months) all patients had a solid lumbar spine fusion. At the 6-month follow up, the pain as assessed on the visual analog scale (VAS) decreased from 6.9 to 4.5 (33% decrease), and the Oswestry disability index (ODI) reduced from 48.0 to 31.7 with a 34% reduction. However, at 2 years follow up there was a trend for increase in the ODI (35) and VAS (5). The data in this study suggest that harvesting a cylinder of autograft from the adjacent vertebral body is safe and efficient. Filling of the void defect with a beta-tricalcium phosphate plug does not preclude the use of posterior pedicle screw stabilization.
...
PMID:Harvesting local cylinder autograft from adjacent vertebral body for anterior lumbar interbody fusion: surgical technique, operative feasibility and preliminary clinical results. 1659 84
The authors report the case of an 83-year-old woman with refractory sciatica attributable to isthmic spondylolisthesis at L-5. Her symptoms were successfully improved after posterior lumbar interbody fusion (PLIF) at L5-S1; however, notable swelling in her left leg suddenly developed 2 days postoperatively. Anterior migration of a fragment of bone graft was demonstrated on computed tomography scanning, and there was obvious occlusion of the left common iliac vein (CIV) on magnetic resonance venography. Ultrasonography revealed a thrombus in the left CIV at the site of compression. To prevent a pulmonary embolism during manipulation of the affected vein, an inferior vena cava filter was placed just before excision of the migrated bone fragment. The swelling in the patient's leg subsided quickly after the surgery, and she was treated with heparin and warfarin to prevent recurrent
deep vein thrombosis
(
DVT
). Six months after the second surgery, complete restoration of blood flow to the left CIV and no recurrence of
DVT
were demonstrated on magnetic resonance venography. Especially in elderly patients with
degenerative disc disease
, excessive curettage and impaction of disc materials during the PLIF procedure may cause migration of bone graft fragments. Surgeons should be aware of the possible vascular complications of PLIF.
...
PMID:Deep vein thrombosis due to migrated graft bone after posterior lumbosacral interbody fusion. Case report. 1723 90